Guiren Wang

Prof. Guiren Wang

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
MAMohammed Alshareef
Mohammed Alshareef
NMNicholas Metrakos
Nicholas Metrakos
EPEva Juarez Perez
Eva Juarez Perez
FAFadi Azer
Fadi Azer
FYFang Yang
Fang Yang
GWGuiren Wang
Guiren Wang
The present work demonstrates the use of a dielectrophoretic lab-on-a-chip device in effectively separating different cancer cells of epithelial origin for application in circulating tumor cell (CTC) identification. This study uses dielectrophoresis (DEP) to distinguish and separate MCF-7 human breast cancer cells from HCT-116 colorectal cancer cells. The DEP responses for each cell type were measured against AC electrical frequency changes in solutions of varying conductivities. Increasing the conductivity of the suspension directly correlated with an increasing frequency value for the first cross-over (no DEP force) point in the DEP spectra. Differences in the cross-over frequency for each cell type were leveraged to determine a frequency at which the two types of cell could be separated through DEP forces. Under a particular medium conductivity, different types of cells could have different DEP behaviors in a very narrow AC frequency band, demonstrating a high specificity of DEP. Using a microfluidic DEP sorter with optically transparent electrodes, MCF-7 and HCT-116 cells were successfully separated from each other under a 3.2 MHz frequency in a 0.1X PBS solution. Further experiments were conducted to characterize the separation efficiency (enrichment factor) by changing experimental parameters (AC frequency, voltage, and flow rate). This work has shown the high specificity of the described DEP cell sorter for distinguishing cells with similar characteristics for potential diagnostic applications through CTC enrichment.

23 January 2014 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
GWGuiren Wang
Guiren Wang
FYFang Yang
Fang Yang
WZWei Zhao
Wei Zhao
Turbulence is commonly viewed as a type of macroflow, where the Reynolds number (Re) has to be sufficiently high. In microfluidics, when Re is below or on the order of 1 and fast mixing is required, so far only chaotic flow has been reported to enhance mixing based on previous publications since turbulence is believed not to be possible to generate in such a low Re microflow. There is even a lack of velocimeter that can measure turbulence in microchannels. In this work, we report a direct observation of the existence of turbulence in microfluidics with Re on the order of 1 in a pressure driven flow under electrokinetic forcing using a novel velocimeter having ultrahigh spatiotemporal resolution. The work could provide a new method to control flow and transport phenomena in lab-on-a-chip and a new perspective on turbulence.

12 January 2010 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
FYFang Yang
Fang Yang
XYXiaoming Yang
Xiaoming Yang
HJHong Jiang
Hong Jiang
PBPhillip Bulkhaults
Phillip Bulkhaults
PWPatricia Wood
Patricia Wood
GWGuiren Wang
Guiren Wang
Separation of colorectal cancer cells from other biological materials is important for stool-based diagnosis of colorectal cancer. In this paper, we use conventional dielectrophoresis in a microfluidic chip to manipulate and isolate HCT116 colorectal cancer cells. It is noticed that at a particular alternating current frequency band, the HCT116 cells are clearly deflected to a side channel from the main channel after the electric activation of an electrode pair. This motion caused by negative dielectrophoresis can be used to simply and rapidly separate cancer cells from other cells. In this manuscript, we report the chip design, flow conditions, dielectrophoretic spectrum of the cancer cells, and the enrichment factor of the colorectal cancer cells from other cells.

1 June 2020 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
LZLibo Zhang
Libo Zhang
ABAndrew Beatty
Andrew Beatty
LLLin Lu
Lin Lu
AAAkrm Abdalrahman
Akrm Abdalrahman
TMThomas M. Makris
Thomas M. Makris
QWQian Wang
Qian Wang

2 February 2016 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
GWGuiren Wang
Guiren Wang
FYFang Yang
Fang Yang
WZWei Zhao
Wei Zhao
CCChien-Pin Chen
Chien-Pin Chen
We recently demonstrated the direct observation of micro-electrokinetic turbulence in a microchannel at a low Reynolds number (Re) when a pressure-driven flow was forced electrokinetically.

17 November 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CKCuifang Kuang
Cuifang Kuang
GWGuiren Wang
Guiren Wang
For the first time we have been able to measure the flow velocity profile for nanofluidics with a spatial resolution better than 70 nm. Due to the diffraction resolution barrier, traditional optical methods have so far failed in measuring the velocity profile in a nanocapillary or a closed nanochannel without an opened sidewall. A novel optical point measurement method is presented which applies stimulated emission depletion (STED) microscopy to laser induced fluorescence photobleaching anemometer (LIFPA) techniques to measure flow velocity. Herein we demonstrate this far-field nanoscopic velocimetry method by measuring the velocity profile in a nanocapillary with an inner diameter of 360 nm. The closest measuring point to the wall is about 35 nm. This method opens up a new class of functional measuring techniques for nanofluidics and for nanoscale flows from the wall.