Shikha Awasthi

Dr. Shikha Awasthi


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2020 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
SAShikha Awasthi
Shikha Awasthi
SPSarvesh Pandey
Sarvesh Pandey
EAE. Arunan
E. Arunan
CSChandan Srivastava
Chandan Srivastava
The production of hydroxyapatite (HAP) composite coatings has continuously been investigated for bone tissue applications during the last few decades due to their significant bioactivity and osteoconductivity. Herein, we highlight the recent experimental and theoretical progresses on HAP coatings, which may bridge the existing gap between theory and practice. The experimental studies mainly deal with electrochemical (EC) and electrophoretic (EP) deposition for the synthesis of nano-HAP in the form of coatings. Additionally, the biocompatible coating method for the fabrication of HAP composite coatings, the plasma spraying (PS) technique, and its mechanism are discussed in this review. Furthermore, the adhesion strength, mechanical, tribological and electrochemical phenomena of HAP composite coatings are critically analyzed. Their ameliorated bactericidal activity is also discussed to recognize the possibility of substituted HAP coatings from a clinical perspective. In addition, computational studies on the HAP system are explored in this report, including the first-principles density functional theory, ab initio modeling and molecular dynamics simulations. Thus, the main significance of this review is to present a collective discussion on the structural features, interfacial mechanics and binding aspects by experimental and theoretical investigations for HAP-based biomaterials, which can provide clear insights for the future research related to orthopedic applications.

24 May 2021 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
SAShikha Awasthi
Shikha Awasthi
JGJeet Kumar Gaur
Jeet Kumar Gaur
SPSarvesh Pandey
Sarvesh Pandey
MBMusuvathi S. Bobji
Musuvathi S. Bobji
CSChandan Srivastava
Chandan Srivastava

22 March 2022 in Biomaterials Science
Verified
Journal Article
Closed access
PDF file
NJN. Jagadeeshanayaka
N. Jagadeeshanayaka
SAShikha Awasthi
Shikha Awasthi
SJSudhakar C. Jambagi
Sudhakar C. Jambagi
CSChandan Srivastava
Chandan Srivastava
Hydroxyapatite (HA) has been an excellent replacement for the natural bone in orthopedic applications owing to its close resemblance to the bone properties; however, it is brittle and has low strength. Surface modification techniques have been able to allay such mineral issues by depositing on substrate. These methods, being economical, impart mechanical strength without compromising biocompatibility. In this review article, the discussion is confined to plasma spray (high temperature) and other low temperature surface modification techniques: high-velocity oxy-fuel (HVOF) and cold spray. The processing temperature seems to significantly affect the performance of implants deposited with HA. Monolithic HA may not add enough strength to the bioimplants. Hence, this review discusses selective reinforcements to HA and their roles in enhancing the properties. Herein, a variety of selective reinforcements are discussed, such as carbon allotropes: graphene, carbon nanotubes, and nano diamond; metallic materials: Ag, Sr, Mg, and Ti; ceramic materials: Al2O3, SiO2, ZrO2, and TiO2; multi-materials: Al2O3-CNT/HA, Al2O3–TiO2/HA and others; and functionally graded composites: HA, 20 and 50 wt% Ti–6Al–4V/HA layered coating. Most of these reinforcements could not trade-off between biocompatibility and strength. The detailed in vitro and in vivo studies are still lacking. The literature on the relative effectiveness of these reinforcements is scanty, while the interface between HA coating and reinforcements is seldom explored. This review presents the suitability of thermal spray techniques based on the microstructure, mechanical, and biological properties. Therefore, it is envisaged that the present review can intrigue future researchers to understand the scope of surface coatings in achieving the better performance of implants at clinical trials.

20 April 2022 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
SAShikha Awasthi
Shikha Awasthi
JGJeet Kumar Gaur
Jeet Kumar Gaur
MBM. S. Bobji
M. S. Bobji
CSChandan Srivastava
Chandan Srivastava

1 November 2018 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
PSPragya Shukla
Pragya Shukla
SAShikha Awasthi
Shikha Awasthi
JRJanakarajan Ramkumar
Janakarajan Ramkumar
KBKantesh Balani
Kantesh Balani

28 October 2022 in Materials Chemistry Frontiers
Verified
Journal Article
Closed access
PDF file
SAShikha Awasthi
Shikha Awasthi
SPSarvesh Pandey
Sarvesh Pandey
JGJeet Kumar Gaur
Jeet Kumar Gaur
CSChandan Srivastava
Chandan Srivastava
Hydroxyapatite (HAP) composite coatings on bio-implants have become very significant materials for orthopaedic applications. The additives in the HAP matrix can improve the wear resistance, mechanical strength, weak bonding and brittleness of the HAP. The present work reports comprehensive investigations of experimental and computational studies for commonly used bio-reinforcing agents, functionalized carbon nanotubes (CNT), graphene oxide (GrO) and hexagonal boron nitride (hBN), with HAP. The synergistic effect of lubrication of hBN and strong bonding between HAP and hBN resulted in a lower friction-of-coefficient (0.23) and reduced dissipation energy (4.6 × 10−4 J) for electrophoretically deposited HAP–hBN composite coating when compared to HAP–CNT, HAP–GrO and bare HAP. Furthermore, the high wear resistance with reduced wear volume (1.65 × 10−3 mm3) and wear rate (1.83 × 10−3 mm3 N−1 m−1) of the HAP–hBN composite coating exhibited its remarkable tribological properties for use in bone implants. Moreover, in order to facilitate some lucid insights into the interfacial bonding and nonbonding interactions (i.e. stability), structural, and electronic features of the HAP and HAP–based composite models (HAP–hBN, HAP–GrO, and HAP–CNT), comprehensive DFT are carried out. Remarkably, the HAP–BN composite model was stabilized by multiple Ca–N bonding interactions. With the employment of the electronic structure calculations approach, the HAP–hBN composite model was found to be the most stable among all three dimer complexes (HAP–hBN, HAP–GrO, and HAP–CNT), which was supported by the supramolecular approach (i.e. binding energy), QTAIM and NCI-plot tools. The biological studies of the HAP–hBN coating showed that the cell viability and antibacterial activity were greater than 80%, which shows the perfect bioactivity of the coating. Thus, the HAP–hBN composite coating with perfect hydrophilicity, wear resistance, biocompatibility and strong bonding compared to HAP–CNT and HAP–GrO can be used as an ideal implant material for bone tissue engineering.,