Pascal Lemaitre

Dr. Pascal Lemaitre

Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSN-RES, SCA, LPMA, 91192 Gif-sur-Yvette, France

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2022 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
AJAnthony C. Jones
Anthony C. Jones
AHAdrian Hill
Adrian Hill
JHJohn Hemmings
John Hemmings
Pascal LemaitrePascal Lemaitre
Pascal Lemaitre
AQArnaud Quérel
Arnaud Quérel
SWStephanie Woodward
Stephanie Woodward
Theoretical models of the below-cloud scavenging (BCS) of aerosol by rain yield scavenging rates that are 1–2 orders of magnitude smaller than observations and associated empirical schemes for submicron-sized aerosol. Even when augmented with processes which may explain this disparity, such as phoresis and rear capture in the raindrop wake, the theoretical BCS rates remain an order of magnitude less than observations. Despite this disparity, both theoretical and empirical BCS schemes remain in wide use within numerical aerosol models. BCS is an important sink for atmospheric aerosol, in particular for insoluble aerosol such as mineral dust, which is less likely to be scavenged by in-cloud processes than purely soluble aerosol. In this paper, various widely used theoretical and empirical BCS models are detailed and then applied to mineral dust in climate simulations with the Met Office's Unified Model in order the gauge the sensitivity of aerosol removal to the choice of BCS scheme. We show that the simulated accumulation-mode dust lifetime ranges from 5.4 d in using an empirical BCS scheme based on observations to 43.8 d using a theoretical scheme, while the coarse-mode dust lifetime ranges from 0.9 to 4 d, which highlights the high sensitivity of dust concentrations to BCS scheme. We also show that neglecting the processes of rear capture and phoresis may overestimate submicron-sized dust burdens by 83 %, while accounting for modal widths and mode merging in modal aerosol models alongside BCS is important for accurately reproducing observed aerosol size distributions and burdens. This study provides a new parameterisation for the rear capture of aerosol by rain and is the first to explicitly incorporate the rear-capture mechanism in climate model simulations. Additionally, we answer many outstanding questions pertaining to the numerical modelling of BCS of aerosol by rain and provide a computationally inexpensive BCS algorithm that can be readily incorporated into other aerosol models.

19 May 2014 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
AQArnaud Quérel
Arnaud Quérel
Pascal LemaitrePascal Lemaitre
Pascal Lemaitre
MMM. Monier
M. Monier
EPE. Porcheron
E. Porcheron
AFAndrea Flossmann
Andrea Flossmann
MHM. Hervo
M. Hervo
In the case of severe accident with loss of containment in a nuclear plant, radionuclides are released into the atmosphere in the form of both gases and aerosol particles (Baklanov and Sørensen, 2001). The analysis of radioactive aerosol scavenged by rain after the Chernobyl accident highlights certain differences between the modelling studies and the environmental measurements. Part of these discrepancies can probably be attributed to uncertainties in the efficiencies used to calculate aerosol particle collection by raindrops, particularly drops with a diameter larger than one millimetre. In order to address the issue of these uncertainties, an experimental study was performed to close the gaps still existing for this key microphysical parameter. In this paper, attention is first focused on the efficiency with which aerosol particles in the accumulation mode are collected by raindrops with a diameter of 2 mm. The collection efficiencies measured for aerosol particle in the sub-micron range are quantitatively consistent with previous theoretical model developed by Beard (1974) and thus highlight the major role of rear capture in the submicron range.

1 October 2015 in Fusion Engineering and Design
Verified
Journal Article
Closed access
ARAnthony Rondeau
Anthony Rondeau
JMJonathan P. Merrison
Jonathan P. Merrison
JIJens Jacob Iversen
Jens Jacob Iversen
SPSamuel Peillon
Samuel Peillon
JSJean-Christophe Sabroux
Jean-Christophe Sabroux
ECEric Chassefière
Eric Chassefière

28 March 2017 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
Pascal LemaitrePascal Lemaitre
Pascal Lemaitre
AQArnaud Quérel
Arnaud Quérel
MMMarie Monier
Marie Monier
TMThibault Menard
Thibault Menard
EPEmmanuel Porcheron
Emmanuel Porcheron
AFAndrea Flossmann
Andrea Flossmann
This article presents new measurements of the efficiency with which aerosol particles of accumulation mode size are collected by a 1.25 mm sized raindrop. These laboratory measurements provide the link to reconcile the scavenging coefficients obtained from theoretical approaches with those from experimental studies. We provide here experimental proof of the rear capture mechanism in the flow around drops, which has a fundamental effect on submicroscopic particles. These experiments thus confirm the efficiencies theoretically simulated by Beard (1974). Finally, we propose a semi-analytical expression to take into account this essential mechanism to calculate the collection efficiency for drops within the rain size range.

6 May 2021 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
ADAlexis Dépée
Alexis Dépée
Pascal LemaitrePascal Lemaitre
Pascal Lemaitre
TGThomas Gelain
Thomas Gelain
MMMarie Monier
Marie Monier
AFAndrea Flossmann
Andrea Flossmann
A new In-Cloud Aerosol Scavenging Experiment (In-CASE) has been developed to measure the collection efficiency (CE) of submicron aerosol particles by cloud droplets. Droplets fall at their terminal velocity through a 1 m high chamber in a laminar flow containing aerosol particles. At the bottom of the In-CASE chamber, the droplet train is separated from the aerosol particles flow, and the droplets are collected in an impaction cup, whereas aerosol particles are deposited on a high-efficiency particulate air (HEPA) filter. The collected droplets and the filter are then analysed by fluorescence spectrometry since the aerosol particles are atomised from a sodium fluorescein salt solution (C20H10Na2O5). In-CASE fully controls all the parameters which affect the CE – the droplets and aerosol particles size distributions are monodispersed, the electric charges of droplets and aerosol particles are known and set, and the relative humidity is indirectly controlled via the chamber's temperature. This paper details the In-CASE setup and the dataset of 70 measurements obtained to study the impact of the electric charges on CE. For this purpose, droplets and particles charges are controlled through two charging systems developed in this work – both chargers are detailed below. The droplet charge varies from -3.0×104±1.4×103 to +9.6×104±4.3×103 elementary charges, while the particle charge ranges from zero to -90±9 elementary charges depending on the particle radius. A droplet radius of 48.5±1.1 µm has been considered for four particle dry radii between 100 and 250 nm while the relative humidity level during experiments is 95.1±0.2 %. The measurements are then compared to theoretical models from literature – showing good agreement.

6 May 2021 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
ADAlexis Dépée
Alexis Dépée
Pascal LemaitrePascal Lemaitre
Pascal Lemaitre
TGThomas Gelain
Thomas Gelain
MMMarie Monier
Marie Monier
AFAndrea Flossmann
Andrea Flossmann
A new In-Cloud Aerosol Scavenging Experiment (In-CASE) has been conceived to measure the collection efficiency (CE) of submicron aerosol particles by cloud droplets. In this setup, droplets fall at their terminal velocity through a 1 m high chamber in a laminar flow containing aerosol particles. At the bottom of the In-CASE chamber, the droplet train is separated from the aerosol particle flow – droplets are collected in an impaction cup, whereas aerosol particles are deposited on a high-efficiency particulate air (HEPA) filter. The collected droplets and the filter are then analysed by fluorescence spectrometry since the aerosol particles are atomised from a sodium fluorescein salt solution (C20H10Na2O5). In-CASE fully controls all the parameters which affect the CE – the droplets and aerosol particles size distributions are monodispersed, the electric charges of droplets and aerosol particles are controlled, and the relative humidity is indirectly set via the chamber's temperature. This novel In-CASE setup is presented here as well as the first measurements obtained to study the impact of relative humidity on CE. For this purpose, droplets and particles are electrically neutralised. A droplet radius of 49.6±1.3 µm has been considered for six particle dry radii between 50 and 250 nm and three relative humidity levels of 71.1±1.3 %, 82.4±1.4 % and 93.5±0.9 %. These new CE measurements have been compared to theoretical models from literature which adequately describe the relative humidity influence on the measured CE.