This paper describes a nanometer-scale bending test for a single crystal silicon (Si) fixed beam using an atomic force microscope (AFM). This research focuses on revealing the size effect on the mechanical property of Si beams ranging from a nano- to millimeter scale. Nanometer-scale Si beams, with widths from 200 to 800 nm and a thickness of 255 nm, were fabricated on an Si diaphragm by means of field-enhanced anodization using AFM and anisotropic wet etching. The efficient condition of the field-enhanced anodization could be obtained by changing the bias voltage and the scanning speed of the cantilever. Bending tests for micro- and millimeter-scale Si beams fabricated by a photolithography technique were also carried out using an ultraprecision hardness tester and scratch tester, respectively. Comparisons of Young's modulus and bending strength, of Si among the nano-, micro-, and millimeter scales showed that the specimen size did not have an influence on the Young's modulus in the [110] direction, whereas it produced a large effect on the bending strength. Observations of the fractured surface and calculations of the clack length from Griffith's theory made it clear that the maximum peak-to-valley distance of specimen surface caused the size effect on the bending strength.
Single-walled carbon nanotubes theoretically possess ultimate intrinsic tensile strengths in the 100–200 GPa range, among the highest in existing materials. However, all of the experimentally reported values are considerably lower and exhibit a considerable degree of scatter, with the lack of structural information inhibiting constraints on their associated mechanisms. Here, we report the first experimental measurements of the ultimate tensile strengths of individual structure-defined, single-walled carbon nanotubes. The strength depends on the chiral structure of the nanotube, with small-diameter, near-armchair nanotubes exhibiting the highest tensile strengths. This observed structural dependence is comprehensively understood via the intrinsic structure-dependent inter-atomic stress, with its concentration at structural defects inevitably existing in real nanotubes. These findings highlight the target nanotube structures that should be synthesized when attempting to fabricate the strongest materials.
Cubic silicon carbide is a promising material for Micro Electro Mechanical Systems (MEMS) applications in harsh environ-ments and bioapplications thanks to its large band gap, chemical inertness, excellent corrosion tolerance and capability of growth on a Si substrate. This paper reports the piezoresistive effect of p-type single crystalline 3C-SiC characterized at high temperatures, using anin situmeasurement method. The experimental results show that the highly doped p-type 3C-SiC possesses a relatively stable gauge factor of approximately 25 to 28 at temperatures varying from 300 K to 573 K. Thein situmethod proposed in this study also demonstrated that, the combination of the piezoresistive and thermoresistive effects can increase the gauge factor of p-type 3C-SiC to approximately 20% at 573 K. The increase in gauge factor based on the combination of these phenomena could enhance the sensitivity of SiC based MEMS mechanical sensors.
In this study, the strain-induced change in the magnetic anisotropy of perpendicularly magnetized thin metals (TbFeCo and Pt/Co/Pt) deposited on a polyethylene naphthalate flexible substrate was investigated. The in-plane uniaxial tensile strain was reversibly applied up to 2%. The magnetic anisotropy was reversibly changed in both samples with applied stress. In the TbFeCo film, a marked change in magnetic anisotropy energy of 1.2 × 105 J/m3 was observed. In the Pt/Co/Pt film, where the thickness of Co was 2–4 monolayers, the stress-induced changes in interface and volume contributions to magnetic anisotropy were individually determined.
6 February 2006 in Journal of Microelectromechanical Systems
This paper describes mechanical properties of submicron thick diamond-like carbon (DLC) films used for surface modification in MEMS devices. A new compact tensile tester operating under an atomic force microscope (AFM) is developed to measure Young's modulus, Poisson's ratio and fracture strength of single crystal silicon (SCS) and DLC coated SCS (DLC/SCS) specimens. DLC films with a thickness ranging from 0.11 /spl mu/m to 0.58 /spl mu/m are deposited on 19-/spl mu/m-thick SCS substrate by plasma-enhanced chemical vapor deposition using a hot cathode penning ionization gauge discharge. Young's moduli of the DLC films deposited at bias voltages of -100 V and -300 V are found to be constant at 102 GPa and 121 GPa, respectively, regardless of film thickness. Poisson's ratio of DLC film is also independent of film thickness, whereas fracture strength of DLC/SCS specimens is inversely proportional to thickness. Raman spectroscopy analyses are performed to examine the effect of hydrogen content in DLC films on elastic properties. Raman spectra reveal that a reduction in hydrogen content in the films leads to better elastic properties. Finally, the proposed evaluation techniques are shown to be applicable to sub-micron thick DLC films by finite element analyses.