Shun-Hsi Hsu

Dr. Shun-Hsi Hsu

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2017 in Sensors
Verified
Journal Article
Open access
PDF file
JCJin-Chern Chiou
Jin-Chern Chiou
SHShun-Hsi Hsu
Shun-Hsi Hsu
YHYu-Chieh Huang
Yu-Chieh Huang
GYGuan-Ting Yeh
Guan-Ting Yeh
WLWei-Ting Liou
Wei-Ting Liou
CKCheng-Kai Kuei
Cheng-Kai Kuei
This study presented a wireless smart contact lens system that was composed of a reconfigurable capacitive sensor interface circuitry and wirelessly powered radio-frequency identification (RFID) addressable system for sensor control and data communication. In order to improve compliance and reduce user discomfort, a capacitive sensor was embedded on a soft contact lens of 200 μm thickness using commercially available bio-compatible lens material and a standard manufacturing process. The results indicated that the reconfigurable sensor interface achieved sensitivity and baseline tuning up to 120 pF while consuming only 110 μW power. The range and sensitivity tuning of the readout circuitry ensured a reliable operation with respect to sensor fabrication variations and independent calibration of the sensor baseline for individuals. The on-chip voltage scaling allowed the further extension of the detection range and prevented the implementation of large on-chip elements. The on-lens system enabled the detection of capacitive variation caused by pressure changes in the range of 2.25 to 30 mmHg and hydration level variation from a distance of 1 cm using incident power from an RFID reader at 26.5 dBm.

1 April 2015
Verified
Conference Paper
Closed access
JCJin-Chern Chiou
Jin-Chern Chiou
SHShun-Hsi Hsu
Shun-Hsi Hsu
CKCheng-Kai Kuei
Cheng-Kai Kuei
TWTsung-Wei Wu
Tsung-Wei Wu
In this paper, an addressable UHF EPCGlobal Class1 Gen2 sensor IC for wireless intraocular pressure (IOP) monitoring on contact lens sensor device is proposed. The proposed sensor IC consists of RFID Analog/RF Front End, capacitive sensor readout circuit, and digital processing unit. RFID Analog/RF front end is used for power management and data transmission. Sensor Readout Circuit will convert the measured capacitor value to digital format for digital processing unit. Digital processing unit is used as processor not only for sensor value processing obtained from the sensor readout circuit, but also for bidirectional communication between RFID reader and sensor IC. This sensor IC architecture combined with specific sensor and corresponding sensor readout circuit can be widely used as noninvasive biomedical sensor devices and systems. Wireless communication and sensor data transmission are implemented with UHF RFID technology, providing much flexibility and can reduce self-developed firmware effort for this architecture in the future.

15 January 2024 in IEEJ Transactions on Electrical and Electronic Engineering
Verified
Journal Article
Closed access
CTCheng‐Wei Tsai
Cheng‐Wei Tsai
SHShun-Hsi Hsu
Shun-Hsi Hsu
GYGuan‐Ting Yeh
Guan‐Ting Yeh
YHYu‐Hsuan Huang
Yu‐Hsuan Huang
CHCheng‐Yu Hsu
Cheng‐Yu Hsu
JCJin‐Chern Chiou
Jin‐Chern Chiou