Arindam Ghosh

Arindam Ghosh


Research Focus & Metrics

Academic Career Length

43Years (1984-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2002
Verified
Book
Closed access
AGArindam Ghosh
Arindam Ghosh
GLGerard Ledwich
Gerard Ledwich

1 June 2017 in IEEE Access
Verified
Journal Article
Open access
DKDinesh Dinesh Kumar
Dinesh Dinesh Kumar
FZFiruz Zare
Firuz Zare
AGArindam Ghosh
Arindam Ghosh
To meet the fast-growing energy demand and, at the same time, tackle environmental concerns resulting from conventional energy sources, renewable energy sources are getting integrated in power networks to ensure reliable and affordable energy for the public and industrial sectors. However, the integration of renewable energy in the ageing electrical grids can result in new risks/challenges, such as security of supply, base load energy capacity, seasonal effects, and so on. Recent research and development in microgrids have proved that microgrids, which are fueled by renewable energy sources and managed by smart grids (use of smart sensors and smart energy management system), can offer higher reliability and more efficient energy systems in a cost-effective manner. Further improvement in the reliability and efficiency of electrical grids can be achieved by utilizing dc distribution in microgrid systems. DC microgrid is an attractive technology in the modern electrical grid system because of its natural interface with renewable energy sources, electric loads, and energy storage systems. In the recent past, an increase in research work has been observed in the area of dc microgrid, which brings this technology closer to practical implementation. This paper presents the state-of-the-art dc microgrid technology that covers ac interfaces, architectures, possible grounding schemes, power quality issues, and communication systems. The advantages of dc grids can be harvested in many applications to improve their reliability and efficiency. This paper also discusses benefits and challenges of using dc grid systems in several applications. This paper highlights the urgent need of standardizations for dc microgrid technology and presents recent updates in this area.

30 October 2009 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
RMRitwik Majumder
Ritwik Majumder
BCBalarko Chaudhuri
Balarko Chaudhuri
AGArindam Ghosh
Arindam Ghosh
RMRajat Majumder
Rajat Majumder
GLGerard Ledwich
Gerard Ledwich
FZFiruz Zare
Firuz Zare
This paper investigates the problem of appropriate load sharing in an autonomous microgrid. High gain angle droop control ensures proper load sharing, especially under weak system conditions. However, it has a negative impact on overall stability. Frequency-domain modeling, eigenvalue analysis, and time-domain simulations are used to demonstrate this conflict. A supplementary loop is proposed around a conventional droop control of each DG converter to stabilize the system while using high angle droop gains. Control loops are based on local power measurement and modulation of the d-axis voltage reference of each converter. Coordinated design of supplementary control loops for each DG is formulated as a parameter optimization problem and solved using an evolutionary technique. The supplementary droop control loop is shown to stabilize the system for a range of operating conditions while ensuring satisfactory load sharing.

8 September 2010 in IET Renewable Power Generation
Verified
Journal Article
Closed access
HBHassan Bevrani
Hassan Bevrani
AGArindam Ghosh
Arindam Ghosh
GLGerard Ledwich
Gerard Ledwich
As the use of renewable energy sources (RESs) increases worldwide, there is a rising interest on their impacts on power system operation and control. An overview of the key issues and new challenges on frequency regulation concerning the integration of renewable energy units into the power systems is presented. Following a brief survey on the existing challenges and recent developments, the impact of power fluctuation produced by variable renewable sources (such as wind and solar units) on system frequency performance is also presented. An updated LFC model is introduced, and power system frequency response in the presence of RESs and associated issues is analysed. The need for the revising of frequency performance standards is emphasised. Finally, non-linear time-domain simulations on the standard 39-bus and 24-bus test systems show that the simulated results agree with those predicted analytically.

1 August 2017 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
FBFlorian Barbieri
Florian Barbieri
SRSumedha Rajakaruna
Sumedha Rajakaruna
AGArindam Ghosh
Arindam Ghosh

24 November 2009 in IEEE Transactions on Power Systems
Verified
Journal Article
Open access
RMRitwik Majumder
Ritwik Majumder
AGArindam Ghosh
Arindam Ghosh
GLGerard Ledwich
Gerard Ledwich
FZFiruz Zare
Firuz Zare
This paper proposes a method for power flow control between utility and microgrid through back-to-back converters, which facilitates desired real and reactive power flow between utility and microgrid. In the proposed control strategy, the system can run in two different modes depending on the power requirement in the microgrid. In mode-1, specified amount of real and reactive power are shared between the utility and the microgrid through the back-to-back converters. Mode-2 is invoked when the power that can be supplied by the distributed generators (DGs) in the microgrid reaches its maximum limit. In such a case, the rest of the power demand of the microgrid has to be supplied by the utility. An arrangement between DGs in the microgrid is proposed to achieve load sharing in both grid connected and islanded modes. The back-to-back converters also provide total frequency isolation between the utility and the microgrid. It is shown that the voltage or frequency fluctuation in the utility side has no impact on voltage or power in microgrid side. Proper relay-breaker operation coordination is proposed during fault along with the blocking of the back-to-back converters for seamless resynchronization. Both impedance and motor type loads are considered to verify the system stability. The impact of dc side voltage fluctuation of the DGs and DG tripping on power sharing is also investigated. The efficacy of the proposed control arrangement has been validated through simulation for various operating conditions. The model of the microgrid power system is simulated in PSCAD.