Noninvasive and longitudinal monitoring of tumor oxygenation status using quantitative diffuse reflectance spectroscopy is used to test whether a final treatment outcome could be estimated from early optical signatures in a murine model of head and neck cancer when treated with radiation. Implanted tumors in the flank of 23 nude mice are exposed to of radiation, while 11 animals exposed to sham irradiation serve as controls. Diffuse optical reflectance is measured from the tumors at baseline (prior to irradiation) and then serially until posttreatment. The fastest and greatest increase in baseline-corrected blood oxygen saturation levels are observed from the animals that show complete tumor regression with no recurrence postirradiation, relative to both untreated and treated animals with local recurrences. These increases in saturation are observed starting posttreatment and last up to posttreatment. This preclinical study demonstrates that diffuse reflectance spectroscopy could provide a practical method far more effective than the growth delay assay to prognosticate treatment outcome in solid tumors and may hold significant translational promise.
In reconstructive surgery, the ability to detect blood flow interruptions to grafted tissue represents a critical step in preventing postsurgical complications. We have developed and pilot tested a compact, fiber-based device that combines two complimentary modalities—diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy—to quantitatively monitor blood perfusion. We present a proof-of-concept study on an in vivo porcine model ( ). With a controllable arterial blood flow supply, occlusion studies ( ) were performed on surgically isolated free flaps while the device simultaneously monitored blood flow through the supplying artery as well as flap perfusion from three orientations: the distal side of the flap and two transdermal channels. Further studies featuring long-term monitoring, arterial failure simulations, and venous failure simulations were performed on flaps that had undergone an anastomosis procedure ( ). Additionally, benchtop verification of the DCS system was performed on liquid flow phantoms. Data revealed relationships between diffuse optical measures and state of occlusion as well as the ability to detect arterial and venous compromise. The compact construction of the device, along with its noninvasive and quantitative nature, would make this technology suitable for clinical translation.
Diffuse Correlation Spectroscopy (DCS) is a well-established optical technique that has been used for non-invasive measurement of blood flow in tissues. Instrumentation for DCS includes a correlation device that computes the temporal intensity autocorrelation of a coherent laser source after it has undergone diffuse scattering through a turbid medium. Typically, the signal acquisition and its autocorrelation are performed by a correlation board. These boards have dedicated hardware to acquire and compute intensity autocorrelations of rapidly varying input signal and usually are quite expensive. Here we show that a Raspberry Pi minicomputer can acquire and store a rapidly varying time-signal with high fidelity. We show that this signal collected by a Raspberry Pi device can be processed numerically to yield intensity autocorrelations well suited for DCS applications. DCS measurements made using the Raspberry Pi device were compared to those acquired using a commercial hardware autocorrelation board to investigate the stability, performance, and accuracy of the data acquired in controlled experiments. This paper represents a first step toward lowering the instrumentation cost of a DCS system and may offer the potential to make DCS become more widely used in biomedical applications.
An inverse Monte Carlo based model has been developed to extract intrinsic fluorescence from turbid media. The goal of this work was to experimentally validate the model to extract intrinsic fluorescence of three biologically meaningful fluorophores related to metabolism from turbid media containing absorbers and scatterers. Experimental studies were first carried out on tissue-mimicking phantoms that contained individual fluorophores and their combinations, across multiple absorption, scattering, and fluorophore concentrations. The model was then tested in a murine tumor model to determine both the kinetics of fluorophore uptake as well as overall tissue fluorophore concentration through extraction of the intrinsic fluorescence of an exogenous contrast agent that reports on glucose uptake. Results show the model can be used to recover the true intrinsic fluorescence spectrum with high accuracy () as well as accurately compute fluorophore concentration in both single and multiple fluorophores phantoms when appropriate calibration standards are available. In the murine tumor, the model-corrected intrinsic fluorescence could be used to differentiate drug dose injections between different groups. A strong linear correlation was observed between the extracted intrinsic fluorescence intensity and injected drug dose, compared with the distorted turbid tissue fluorescence.
In diffuse reflectance spectroscopy, the retrieval of the optical properties of a target requires the inversion of a measured reflectance spectrum. This is typically achieved through the use of forward models such as diffusion theory or Monte Carlo simulations, which are iteratively applied to optimize the solution for the optical parameters. In this paper, we propose a novel neural network-based approach for solving this inverse problem, and validate its performance using experimentally measured diffuse reflectance data from a previously reported phantom study. Our inverse model was developed from a neural network forward model that was pre-trained with data from Monte Carlo simulations. The neural network forward model then creates a lookup table to invert the diffuse reflectance to the optical coefficients. We describe the construction of the neural network-based inverse model and test its ability to accurately retrieve optical properties from experimentally acquired diffuse reflectance data in liquid optical phantoms. Our results indicate that the developed neural network-based model achieves comparable accuracy to traditional Monte Carlo-based inverse model while offering improved speed and flexibility, potentially providing an alternative for developing faster clinical diagnosis tools. This study highlights the potential of neural networks in solving inverse problems in diffuse reflectance spectroscopy.
Reliable, continuous and noninvasive blood flow and hemoglobin monitoring in trauma patients remains a critical, but generally unachieved goal. Two optical sensing methods - diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy (DRS) – are used to monitor and detect internal hemorrhage. Specifically, we investigate if cutaneous perfusion measurements acquired using DCS and DRS in peripheral (thighs and ear-lobe) tissues could detect severe hemorrhagic shock in a porcine model. Four animals underwent high-grade hepato-portal injury in a closed abdomen, to induce uncontrolled hemorrhage and were subsequently allowed to bleed for 10 minutes before fluid resuscitation. DRS and DCS measurements of cutaneous blood flow were acquired using fiber optical probes placed on the thigh and earlobe of the animals and were obtained repeatedly starting from 1 to 5 minutes pre-injury, up to several minutes post shock. Clear changes were observed in measured optical spectra across all animals at both sites. DCS-derived cutaneous blood flow decreased sharply during hemorrhage, while DRS-derived vascular saturation and hemoglobin paralleled cardiac output. All derived optical parameters had the steepest changes during the rapid initial hemorrhage unambiguously. This suggests that a combined DCS and DRS based device might provide an easy-to-use, non-invasive, internal-hemorrhage detection system that can be used across a wide array of clinical settings.