Despina Moschou

Dr. Despina Moschou

Department of Electronic and Electrical Engineering, University of Bath, Bath BA2 7AY, UK
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2017 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
DMDespina Moschou
Despina Moschou
Angeliki TserepiAngeliki Tserepi
Angeliki Tserepi
Commercialization of lab-on-a-chip devices is currently the “holy grail” within the μTAS research community. While a wide variety of highly sophisticated chips which could potentially revolutionize healthcare, biology, chemistry and all related disciplines are increasingly being demonstrated, very few chips are or can be adopted by the market and reach the end-users. The major inhibition factor lies in the lack of an established commercial manufacturing technology. The lab-on-printed circuit board (lab-on-PCB) approach, while suggested many years ago, only recently has re-emerged as a very strong candidate, owing to its inherent upscaling potential: the PCB industry is well established all around the world, with standardized fabrication facilities and processes, but commercially exploited currently only for electronics. Owing to these characteristics, complex μTASs integrating microfluidics, sensors, and electronics on the same PCB platform can easily be upscaled, provided more processes and prototypes adapted to the PCB industry are proposed. In this article, we will be reviewing for the first time the PCB-based prototypes presented in the literature to date, highlighting the upscaling potential of this technology. The authors believe that further evolution of this technology has the potential to become a much sought-after standardized industrial fabrication technology for low-cost μTASs, which could in turn trigger the projected exponential market growth of μTASs, in a fashion analogous to the revolution of Si microchips via the CMOS industry establishment.

2 April 2022 in Microchimica Acta
Verified
Journal Article
Open access
PDF file
KBKatarzyna Białas
Katarzyna Białas
DMDespina Moschou
Despina Moschou
FMFrank Marken
Frank Marken
Pedro EstrelaPedro Estrela
Pedro Estrela
Biosensors have attracted a great deal of attention, as they allow for the translation of the standard laboratory-based methods into small, portable devices. The field of biosensors has been growing, introducing innovations into their design to improve their sensing characteristics and reduce sample volume and user intervention. Enzymes are commonly used for determination purposes providing a high selectivity and sensitivity; however, their poor shelf-life is a limiting factor. Researchers have been studying the possibility of substituting enzymes with other materials with an enzyme-like activity and improved long-term stability and suitability for point-of-care biosensors. Extra attention is paid to metal and metal oxide nanoparticles, which are essential components of numerous enzyme-less catalytic sensors. The bottleneck of utilising metal-containing nanoparticles in sensing devices is achieving high selectivity and sensitivity. This review demonstrates similarities and differences between numerous metal nanoparticle-based sensors described in the literature to pinpoint the crucial factors determining their catalytic performance. Unlike other reviews, sensors are categorised by the type of metal to study their catalytic activity dependency on the environmental conditions. The results are based on studies on nanoparticle properties to narrow the gap between fundamental and applied research. The analysis shows that the catalytic activity of nanozymes is strongly dependent on their intrinsic properties (e.g. composition, size, shape) and external conditions (e.g. pH, type of electrolyte, and its chemical composition). Understanding the mechanisms behind the metal catalytic activity and how it can be improved helps designing a nanozyme-based sensor with the performance matching those of an enzyme-based device.Graphical abstract

1 August 2014 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
DMDespina Moschou
Despina Moschou
NVNikolaos Vourdas
Nikolaos Vourdas
GKGeorge Kokkoris
George Kokkoris
GPGeorge Papadakis
George Papadakis
JPJohn Parthenios
John Parthenios
ATAngeliki Tserepi
Angeliki Tserepi

4 September 2020 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
Rosalia MoredduRosalia Moreddu
Rosalia Moreddu
MEMohamed Elsherif
Mohamed Elsherif
HAHadie Adams
Hadie Adams
DMDespina Moschou
Despina Moschou
MCM Francesca Cordeiro
M Francesca Cordeiro
AYAli K. Yetisen
Ali K. Yetisen
In this article, using the integration of paper microfluidics within laser-inscribed commercial contact lenses, we demonstrate the multiplexed detection of clinically relevant analytes including hydrogen ions, proteins, glucose, nitrites and L-ascorbic acid, all sampled directly from model tears. In vitro measurements involved the optimization of colorimetric assays, with readouts collected, stored and analyzed using a bespoke Tears Diagnostics smartphone application prototype. We demonstrate the potential of the device to perform discrete measurements either for medical diagnosis or disease screening in the clinic or at the point-of-care (PoC), with future applications including monitoring of ocular infections, uveitis, diabetes, keratopathies and assessing oxidative stress.

12 February 2021 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
UZUroš Zupančič
Uroš Zupančič
PJPawan Jolly
Pawan Jolly
Pedro EstrelaPedro Estrela
Pedro Estrela
DMDespina Moschou
Despina Moschou
DIDonald E Ingber
Donald E Ingber

1 January 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
PJPawan Jolly
Pawan Jolly
JRJoshua Rainbow
Joshua Rainbow
Anna RegoutzAnna Regoutz
Anna Regoutz
Pedro EstrelaPedro Estrela
Pedro Estrela
DMDespina Moschou
Despina Moschou
We report the development of a Lab-on-PCB DNA diagnostic platform, exploiting peptide nucleic acid (PNA) sequences as probes. The study demonstrates the optimization and characterization of two commercial PCB manufacturing gold electroplating processes for biosensing applications. Using an optimized ratio of PNA with a spacer molecule (MCH), the lowest limit of detection (LoD) to date for PCB-based DNA biosensors of 57 fM is reported. The study also showcases a fully integrated Lab-on-PCB microsystem designed for rapid detection, which employs PCB-integrated sample delivery, achieving DNA quantification in the 0.1-100 pM range for 5 μL samples analyzed within 5 min under continuous flow. The demonstrated biosensor proves the capability of PCB-based DNA biosensors for high sensitivity and paves the way for their integration in Lab-on-PCB DNA diagnostic microsystems.