Arun Arjunan

Prof. Arun Arjunan

School of Engineering, University of Wolverhampton, Wolverhampton TF29NT, UK
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in International Journal of Thermofluids
Verified
Journal Article
Open access
Ahmad BaroutajiAhmad Baroutaji
Ahmad Baroutaji
Arun ArjunanArun Arjunan
Arun Arjunan
MRMohamad Ramadan
Mohamad Ramadan
JRJohn Robinson
John Robinson
AAAbed Alaswad
Abed Alaswad
AOAbdul-Ghani Olabi
Abdul-Ghani Olabi

29 January 2024 in Building and Environment
Verified
Journal Article
Open access
Arun ArjunanArun Arjunan
Arun Arjunan
ABAhmad Baroutaji
Ahmad Baroutaji
JRJohn Robinson
John Robinson
AVAaron Vance
Aaron Vance
AAAbul Arafat
Abul Arafat

1 February 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Arun ArjunanArun Arjunan
Arun Arjunan
MDMarios Demetriou
Marios Demetriou
Ahmad BaroutajiAhmad Baroutaji
Ahmad Baroutaji
CWChang Jiang Wang
Chang Jiang Wang

1 January 2021 in Engineering Structures
Verified
Journal Article
Closed access
ABAhmad Baroutaji
Ahmad Baroutaji
Arun ArjunanArun Arjunan
Arun Arjunan
MSMark Stanford
Mark Stanford
JRJohn Robinson
John Robinson
AOAbdul Ghani Olabi
Abdul Ghani Olabi

1 February 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Arun ArjunanArun Arjunan
Arun Arjunan
SZSuhaib Zahid
Suhaib Zahid
Ahmad BaroutajiAhmad Baroutaji
Ahmad Baroutaji
JRJohn Robinson
John Robinson

1 July 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
KBKlaudio Bari
Klaudio Bari
Arun ArjunanArun Arjunan
Arun Arjunan
Lattice structure based morphologically matched scaffolds is rapidly growing facilitated by developments in Additive Manufacturing. These porous structures are particularly promising due to their potential in reducing stress shielding and maladapted stress concentration. Accordingly, this study presents Extra Low Interstitial (ELI) Titanium alloy based morphological scaffolds featuring three different porous architecture. All scaffolds were additively manufactured using Selective Laser Melting from Ti6Al4V ELI with porosities of 73.85, 60.53 and 55.26% with the global geometry dictated through X-Ray Computed Tomography. The elastic and plastic performance of both the scaffold prototypes and the bone section being replaced were evaluated through uniaxial compression testing. Comparing the data, the suitability of the Maxwell criterion in evaluating the stiffness behaviour of fully porous morphological scaffolds are carried out. The outcomes show that the best performing scaffolds presented in this study have high strength (169 MPa) and low stiffness (5.09 GPa) suitable to minimise stress shielding. The matching morphology in addition to high porosity allow adequate space for flow circulation and has the potential to reduce maladapted stress concentration. Finally, the Electron Diffraction X-ray analysis revealed a small difference in the composition of aluminium between the particle and the bonding material at the scaffold surface.