Due the rapid expansion of frac sand production, local residents, community leaders, and state regulatory authorities have expressed concerns regarding the lack of ambient respirable crystalline silica concentration data for areas near to these facilities. Long-term average data are needed to compare the fence line concentrations against chronic reference exposure guidelines such as the one adopted by the California Office of Environmental Health Hazard Assessment (OEHHA). This paper provides comprehensive sets of 24 h respirable crystalline silica concentration measurements compiled during multi-year sampling programs at the fence lines of four Wisconsin facilities—three frac sand mines and one frac sand processing plant. The authors adapted Environmental Protection Agency (EPA) reference method PM2.5 filter-based samplers to provide respirable (PM4) filter samples. Crystalline silica content of the PM4 particulate matter samples was measured using National Institute of Occupational Safety and Health (NIOSH) Method 7500 X-ray diffraction. The respirable crystalline silica limit of quantification was 0.31 µg/m3. The geometric mean (GM) respirable crystalline silica concentrations at the fence lines of the frac sand-producing facilities were less than 10% of the 3.0 µg/m3 California OEHHA chronic exposure level and were consistent with background concentrations throughout the upper Midwest of the U.S.
1 November 2009 in Journal of the Air & Waste Management Association
The California Construction and Industrial Minerals Association and the National Stone, Sand, & Gravel Association have sponsored tests at three sand and gravel plants in California to compile crys...
Ambient respirable crystalline silica air quality is of concern to many communities near mineral processing facilities and to regulatory agencies serving these communities. Accurate air quality data are needed to compare measured respirable crystalline silica concentrations at the fencelines of mineral processing facilities with the published health effect guideline published by the California Office of Health Hazard Assessment (OEHHA). This article is a compilation and evaluation of air quality studies around a diverse set of nineteen sand producing facilities. The respirable crystalline silica air quality data compiled by Air Control Techniques, P.C. and most of the data compiled by other researchers cited in this article have been measured using EPA Reference Method samplers adjusted for respirable crystalline silica sampling and NIOSH Method 7500 X-ray diffraction analyses. The authors conclude that (1) the ambient concentrations in the diverse set of mineral processing facilities were consistently lower than the 3.0 microgram per cubic meter chronic reference exposure level (REL) adopted by OEHHA, (2) upwind-to-downwind fenceline concentration differences were small, and (3) the fenceline t concentrations were often at background concentration levels. The authors recommend additional sampling studies to better characterize background concentrations of ambient respirable crystalline silica.
This paper is part of a set of papers concerning the possible health implications of ambient respirable crystalline silica beyond the fencelines of mineral industry sources such as frac sand, construction sand, crushed stone, and specialty silica product plants. Previously published ambient respirable crystalline silica data relevant to mineral industry sources are reviewed to identify the typical and maximum downwind ambient respirable crystalline silica concentrations expected beyond facility fencelines. These typical and maximum downwind concentrations can be used in risk assessment studies. Relevant RCS facility downwind and upwind ambient data sets previously compiled by the authors, state regulatory agencies, the Agency for Toxic Substances and Disease Registration (ASTDR), and academic researchers are reviewed. Emphasis is placed on data sets compiled in multi-year sampling programs that take into account seasonal variations and facility operational variations. To the extent possible, data from different geographic areas are included to account for differing background (upwind) concentrations. The ambient RCS data are condensed to yield mean and maximum long-term average concentrations that can be used in risk assessment studies. There is a high degree of consistency in the RCS concentration data published by numerous researchers at a wide variety of mineral industry facilities. The authors recommend a mean concentration of 0.28 μg/m3 as an estimate of the long term average RCS concentration downwind of the fencelines of typical mineral industry facilities and a maximum concentration of 1.5 μg/m3 as an estimate of 95% upper confidence level of the mean RCS concentration downwind of the fencelines of especially large mineral industry facilities and/or those facilities where the very hilly terrain limit dispersion of facility emissions. The authors recommend a mean concentration of 0.22 μg/m3 as an estimate of the typical long term average background concentrations. If there are community health concerns at the RCS concentrations in the range of 0.22 to 0.28 μg/m3, new measurement procedures that provide higher 24-h sample volumes and/or more sensitive analytical techniques would be needed to provide accurate community exposure data.