Roberta Esposito

Dr. Roberta Esposito

Department of Clinical Medicine and Surgery, University of Naples Federico II, Naples, Italy
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2018 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
TSTadafumi Sugimoto
Tadafumi Sugimoto
SRSébastien Robinet
Sébastien Robinet
RDRaluca Dulgheru
Raluca Dulgheru
ABAnne Bernard
Anne Bernard
Federica IlardiFederica Ilardi
Federica Ilardi
PLPatrizio Lancellotti
Patrizio Lancellotti
To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function were 26.1%, 48.7%, and 41.4% for left atrial strain (LAS), 2D left atrial emptying fraction (LAEF), and 3D LAEF (reservoir function); 7.7%, 24.2%, and −0.53/s for LAS-active, LAEF-active, and LA strain rate during LA contraction (SRa) (pump function) and 12.0% and 21.6% for LAS-passive and LAEF-passive (conduit function). Left atrial reservoir and conduit function were decreased with age while pump function was increased. All indices of reservoir function and all LA strains had no difference in both gender and vendor. However, inter-vendor differences were observed in LA SRa despite the use of VIS. The NORRE study provides contemporary, applicable echocardiographic reference ranges for LA function. Our data highlight the importance of age-specific reference values for LA functions.

1 September 2013 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
FMFrancesco Maffessanti
Francesco Maffessanti
DMDenisa Muraru
Denisa Muraru
RERoberta Esposito
Roberta Esposito
PGPaola Gripari
Paola Gripari
DEDavide Ermacora
Davide Ermacora
LBLuigi P. Badano
Luigi P. Badano
Background—: Right ventricular (RV) volumes and ejection fraction (EF) vary significantly with demographic and anthropometric factors and are associated with poor prognosis in several cardiovascular diseases. This multicenter study was designed to (1) establish the reference values for RV volumes and EF using transthoracic three-dimensional (3D) echocardiography; (2) investigate the influence of age, sex, and body size on RV anatomy; (3) develop normative equations. Methods and Results—: RV volumes (end-diastolic volume and end-systolic volume), stroke volume, and EF were measured by 3D echocardiography in 540 healthy adult volunteers, prospectively enrolled, evenly distributed across age and sex. The relation of age, sex, and body size parameters was investigated using bivariate and multiple linear regression. Analysis was feasible in 507 (94%) subjects (260 women; age, 45±16 years; range, 18–90). Age, sex, height, and weight significantly influenced RV volumes and EF. Sex effect was significant ( P <0.01), with RV volumes larger and EF smaller in men than in women. Older age was associated with lower volumes (end-diastolic volume, −5 mLdecade; end-systolic volume, −3 mL/decade; EF, −2 mL/decade) and higher EF (+1% per decade). Inclusion of body size parameters in the statistical models resulted in improved overall explained variance for volumes (end-diastolic volume, R 2 =0.43; end-systolic volume, R 2 =0.35; stroke volume, R 2 =0.30), while EF was unaffected. Ratiometric and allometric indexing for age, sex, and body size resulted in no significant residual correlation between RV measures and height or weight. Conclusions—: The presented normative ranges and equations could help standardize the 3D echocardiography assessment of RV volumes and function in clinical practice, considering the effects of age, sex, and body size.

1 November 2010 in Journal of the American Society of Echocardiography
Verified
Journal Article
Closed access
MGMaurizio Galderisi
Maurizio Galderisi
VLVincenzo Schiano Lomoriello
Vincenzo Schiano Lomoriello
ASAlessandro Santoro
Alessandro Santoro
RERoberta Esposito
Roberta Esposito
MOMarinella Olibet
Marinella Olibet
GLGaetano Lombardi
Gaetano Lombardi

31 March 2017 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
CSCiro Santoro
Ciro Santoro
GAGrazia Arpino
Grazia Arpino
RERoberta Esposito
Roberta Esposito
MLMaria Lembo
Maria Lembo
IPImmacolata Paciolla
Immacolata Paciolla
MGMaurizio Galderisi
Maurizio Galderisi
2D echocardiography is limited for identifying chemotherapy-related cardiotoxicity. This study compared standard echo, 2D, and 3D speckle tracking echocardiography (STE) for detection of subclinical anthracycline (ANT) cardiotoxicity in breast cancer patients. One-hundred consecutive breast cancer patients free of cardiac symptoms were treated by multiple protocols including ANT and cyclophosphamide and/or 5-fluorouracil for 3–4 cycles. Both before and after treatment, patients underwent standard echo, 2D STE-derived left ventricular (LV) global longitudinal strain (GLS), 3D volumetric echo and 3D STE with measurements of GLS, global circumferential strain (GCS), global area strain (GAS), and global radial strain (GRS). The follow-up period from the beginning of cancer therapy was 129 ± 18 days. All patients completed the chemotherapy cycles, without experiencing symptoms/signs of heart failure. 2D ejection fraction (EF) was not significantly changed after treatment, whereas E/e’ ratio was higher than baseline (from 6.9 ± 2.2 to 7.3 ± 2.1, P = 0.006). 2D GLS was reduced after treatment (from −22.2 ± 2.3% to − 20.1 ± 6.6%, P = 0.004). 3D derived LV end-systolic volume was increased (P < 0.01) and 3D EF (from 62.4 ± 6.5% to 60.3 ± 7.3%, P < 0.01), 3D GLS (P < 0.001) GRS (P < 0.002), GCS, and GAS (both P < 0.0001) were reduced after ANT. Post-ANT 2D GLS was feasible in 90%, 3D EF in 66%, and 3D STE in 60% of patients. Our study demonstrates potential superiority but also suboptimal feasibility of 3D EF and 3D strain in diagnosing subclinical ANT cardiotoxicity in breast cancer patients. 2D GLS is superior to standard echo and presents a good feasibility. E/e’ ratio also offers advantages in revealing cardiotoxicity.

26 November 2010 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
MGMaurizio Galderisi
Maurizio Galderisi
ASAlessandro Santoro
Alessandro Santoro
MVMarco Versiero
Marco Versiero
VLVincenzo Schiano Lomoriello
Vincenzo Schiano Lomoriello
RERoberta Esposito
Roberta Esposito
GSGiovanni de Simone
Giovanni de Simone
Miniaturization has evolved in the creation of a pocket-size imaging device which can be utilized as an ultrasound stethoscope. This study assessed the additional diagnostic power of pocket size device by both experts operators and trainees in comparison with physical examination and its appropriateness of use in comparison with standard echo machine in a non-cardiologic population.

9 February 2012 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
MGMaurizio Galderisi
Maurizio Galderisi
RERoberta Esposito
Roberta Esposito
VSVincenzo Schiano-Lomoriello
Vincenzo Schiano-Lomoriello
ASAlessandro Santoro
Alessandro Santoro
RIRenato Ippolito
Renato Ippolito
GSGiovanni de Simone
Giovanni de Simone
The present study aimed to test the capability of real-time three-dimensional echocardiography (RT3DE) in characterizing early abnormalities of left ventricular (LV) structure and function in native, untreated hypertensive patients. Thirty-eight newly diagnosed, never-treated hypertensives (H) and 38 healthy controls (C) underwent both standard echo-Doppler and RT3DE assessment. LV volumes and ejection fraction (EF), sphericity index, LV mass index (LVMi), global longitudinal strain (GLS), global circumferential strain (GCS), global area strain (GAS), and global radial strain (GRS) were calculated by RT3DE. The two groups were comparable for age and heart rate. Body mass index and blood pressure (BP) were significantly higher in H. LV volumes, EF, and sphericity index calculated by RT3DE did not differ significantly between the two groups, while LVMi was higher in H than in C (P< 0.0001). GAS (−29.1 ± 2.5% in H vs. −33.6 ± 3.4% in C), GLS, and GRS (all P< 0.0001) were lower in H, but GCS was not significantly different between the two groups. Among the different 3D strain components, GAS showed the best independent associations with mean BP (β = −0.502, P< 0.0001) and LVMi (β = −0.385, P< 0.001; cumulative R2 = 0.55, P< 0.0001) in the pooled population. RT3DE identifies early functional LV changes in native hypertensive patients. GAS is precociously reduced, and longitudinal and radial strain impaired, while circumferential strain is still preserved, supporting a normal LV chamber systolic function. Reduction of GAS is independently associated with both pressure overload and magnitude of the LV mass.