Grahame Douglas

Dr. Grahame Douglas

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2022 in Fire
Verified
Journal Article
Open access
PDF file
MHMd Delwar Hossain
Md Delwar Hossain
Md Kamrul HassanMd Kamrul Hassan
Md Kamrul Hassan
MAMahmoud Akl
Mahmoud Akl
Sameera Wijesiri PathiranaSameera Wijesiri Pathirana
Sameera Wijesiri Pathirana
Payam RahnamayiezekavatPayam Rahnamayiezekavat
Payam Rahnamayiezekavat
Saha SwapanSaha Swapan
Saha Swapan
The energy efficiency of buildings drives the replacement of traditional construction materials with lightweight insulating materials. However, energy-efficient but combustible insulation might contribute to the building’s fire load. Therefore, it is necessary to analyse the reaction-to-fire properties of various insulating materials to provide a better understanding of designing a fire-safe structure. In this study, reaction-to-fire tests were carried out to assess the fire behaviour of lightweight polystyrene insulating panels commonly employed in high-rise buildings. The flammability characteristics of expanded polystyrene (EPS) and extruded polystyrene (XPS) were determined using a cone calorimeter under two distinct external irradiance regimes, 35 kW/m2 and 50 kW/m2, to approximate small to medium fire exposure situations. To investigate the effect of a fire-rated (FR) foil layer on a sandwich panel, three distinct test configurations were used: (i) sample without FR layer (standard sample), (ii) sample with FR layer (FR foil), and (iii) damaged layer (foil and vent) for EPS. Except for the smoke toxicity index (STI), the overall fire performance of EPS is superior to that of XPS. The findings of this study are useful in analysing fire performance and fire safety design for lightweight insulation panels.

19 January 2023 in Fire
Verified
Journal Article
Open access
PDF file
KFKyle Farrell
Kyle Farrell
Md Kamrul HassanMd Kamrul Hassan
Md Kamrul Hassan
MHMd Delwar Hossain
Md Delwar Hossain
Bulbul AhmedBulbul Ahmed
Bulbul Ahmed
Payam RahnamayiezekavatPayam Rahnamayiezekavat
Payam Rahnamayiezekavat
Saha SwapanSaha Swapan
Saha Swapan
Interest in water mist fire suppression has increased within the fire protection industry due to its ability to control the spread and development of fire without using environmentally damaging agents. Water mist fire suppression has been used for many years in various applications such as machinery spaces, combustion turbine enclosures, and onboard passenger sea vessels. Now there is a demand to use this firefighting method to protect other fire risks such as cooking areas, commercial buildings, residential buildings, electrical equipment, road tunnels, bushfire (wildland fire) protection, and nuclear power generation facilities. To support this industry demand, this review covers the fundamentals of water mist, its suppression mechanisms, areas of application, existing research and development, and the codes and standards related to design. This comprehensive review provides a clear history of water mist suppression. It is able to identify the issues and challenges related to the technology to help pave the way for future research and development that will improve these systems to a level so that they are suitable for these new applications and meet the industry demand for nontoxic fire suppression systems.

21 August 2023 in Fire
Verified
Journal Article
Open access
PDF file
Md Kamrul HassanMd Kamrul Hassan
Md Kamrul Hassan
NHNazra Hameed
Nazra Hameed
MHMd Delwar Hossain
Md Delwar Hossain
Md Rayhan HasnatMd Rayhan Hasnat
Md Rayhan Hasnat
GDGrahame Douglas
Grahame Douglas
Saha SwapanSaha Swapan
Saha Swapan
Electric Vehicles (EVs) offer a promising solution to reduce the environmental impact compared to internal combustion engine vehicles. However, EV adoption in Australia has been hindered by concerns over fire safety. This study aims to comprehensively analyse EV fire risks and trends in Australia, including those related to charging stations and lithium-ion batteries. The research utilises secondary data from various reputable sources to develop statistical forecasting models, which estimate that Australia will have approximately 1.73 million EVs by 2030 and 15.8 million by 2050. The study reveals an average EV fire frequency of six fires per million EVs in Australia, aligning with the global average. Consequently, Australia is expected to experience 9 to 10 EV fire incidents annually in 2030, 37 to 42 EV fire incidents annually in 2040, and 84 to 95 EV fire incidents annually in 2050. To address these risks, an EV fire risk control framework is considered to identify and recommend appropriate measures for life safety, lithium-ion batteries, charging, EV handling, and EV locations. This research provides vital evidence for regulators, policymakers, and the fire industry to effectively manage EV fire risks and enhance preparedness for the growing EV market in Australia.

26 September 2022 in Fire
Verified
Journal Article
Open access
PDF file
Md Kamrul HassanMd Kamrul Hassan
Md Kamrul Hassan
MHMd Delwar Hossain
Md Delwar Hossain
MGMichael Gilvonio
Michael Gilvonio
Payam RahnamayiezekavatPayam Rahnamayiezekavat
Payam Rahnamayiezekavat
GDGrahame Douglas
Grahame Douglas
Saha SwapanSaha Swapan
Saha Swapan
This paper investigates aluminium composite panels (ACPs) to understand the fire behaviour of combustible cladding systems under different fire scenarios. A fire dynamics simulator (FDS) is used to develop the numerical model of full-scale fire tests of combustible cladding systems using the procedures of the British BS 8414.1 standards. The results obtained from the FDS models are verified with test data. Seven test scenarios are investigated with four distinct parameters, i.e., cavity barrier, air-cavity gap, panel mounting (with and without joining gaps between the panels), and material combustibility qualities. A critical air-cavity gap (50–100 mm) is established at which maximum fire spread is noticed. Furthermore, variations in the cavity barrier, panel mounting, and material combustibility significantly impact the rapid fire spread of ACP cladding systems and the internal failure criterion. The results from the present study can serve as a basis for future research on the full-scale fire-test development of combustible ACPs.

22 February 2023 in Fire
Verified
Journal Article
Open access
PDF file
Md Kamrul HassanMd Kamrul Hassan
Md Kamrul Hassan
Md Rayhan HasnatMd Rayhan Hasnat
Md Rayhan Hasnat
KLKai Png Loh
Kai Png Loh
MHMd Delwar Hossain
Md Delwar Hossain
Payam RahnamayiezekavatPayam Rahnamayiezekavat
Payam Rahnamayiezekavat
Saha SwapanSaha Swapan
Saha Swapan
Laminated glass is prominently used nowadays as building construction material in the façade and architectural glazing of high-rise buildings. On the other hand, the fire safety of the high-rise building with laminated glass is also receiving more attention from the fire safety regulatory authorities and researchers due to recent fire incidents. Different interlayer polymeric materials are used in modern laminated glass to prevent the breakage of the glass façade, which can also increase the fire risk through a lower ignition time, and higher heat release and smoke production. Therefore, further research is required to understand the fire behaviour of laminated glass. In this study, the fire performance of the laminated glass has been investigated using cone calorimeter testing and the effect of different parameters such as glass thickness (6, 10, 12 mm), interlayer materials (PVB, SGP and EVA) and heat flux (25, 50 and 75 kW/m2) on the fire behaviour of laminated glass has been studied. It is found that the glass thickness, interlayer material and heat flux can significantly influence the reaction-to-fire properties such as peak heat release rate (pHRR), total heat release, time to ignition, and smoke production of laminated glass. In addition, total smoke production (TSP) is also very high for PVB (3.146 m2) and SGP (3.898 m2) laminated glass compared to EVA (0.401 m2) laminated glass and it is affected by these parameters. Finally, a simplified equation is developed to predict the pHRR of laminated glass by correlating the mass loss and external heat flux.

1 January 2014 in Fire Safety Science
Verified
Journal Article
Closed access
PDF file
GDGrahame Douglas
Grahame Douglas
YHY. He
Y. He
YXY. Xiang
Y. Xiang
EME. Charles Morris
E. Charles Morris