jianlin Li

Dr. jianlin Li

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2018 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
RLRui Liu
Rui Liu
WLWei Li
Wei Li
TCTingting Cai
Tingting Cai
YDYang Deng
Yang Deng
ZDZhi Ding
Zhi Ding
JLjianlin Li
jianlin Li

18 October 2017 in Analytical Chemistry
Verified
Journal Article
Closed access
PSPeng Shen
Peng Shen
WLWei Li
Wei Li
YLYan Liu
Yan Liu
ZDZhi Ding
Zhi Ding
YDYang Deng
Yang Deng
TZTiesong Zheng
Tiesong Zheng

16 September 2021 in Journal of Agricultural and Food Chemistry
Verified
Journal Article
Closed access
JSJialong Sun
Jialong Sun
WLWei Li
Wei Li
XZXuerui Zhu
Xuerui Zhu
SJSaisai Jiao
Saisai Jiao
YCYunwei Chang
Yunwei Chang
JLjianlin Li
jianlin Li

23 May 2023 in Food Chemistry
Verified
Journal Article
Closed access
XWXiu Wang
Xiu Wang
WLWei Li
Wei Li
SDShijie Dai
Shijie Dai
MDMenghua Dou
Menghua Dou
SJSaisai Jiao
Saisai Jiao
JLjianlin Li
jianlin Li

12 April 2022 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
SWSiwei Wang
Siwei Wang
RSRui Shao
Rui Shao
WLWeiwei Li
Weiwei Li
XLXiang Li
Xiang Li
JSJialong Sun
Jialong Sun
JLjianlin Li
jianlin Li

29 November 2013 in The Analyst
Verified
Journal Article
Closed access
PDF file
KXKun Xu
Kun Xu
YSYue Sun
Yue Sun
WLWei Li
Wei Li
JXJie Xu
Jie Xu
BCBin Cao
Bin Cao
DPDaodong Pan
Daodong Pan
A novel multiplex chemiluminescent mycotoxin immunoassay suspension array system was developed by combining the silica photonic crystal microspheres (SPCMs) encoding technique and a chemiluminescent immunoassay (CLIA) method. The SPCMs were used as a carrier of the suspension array and encoded by their reflectance peak positions, which overcome fluorescence photobleaching, and the potential interference between the encoding fluorescence and detection fluorescence. Aflatoxin B1 (AFB1), fumonisin B1 (FB1) and ochratoxin A (OTA) artificial antigens were immobilized on the surfaces of SPCMs by using 3-glycidoxypropyltrimethoxysilane as a linker. Horseradish peroxidase (HRP) was used as a labeling enzyme for the secondary antibody in the enzyme-catalyze H2O2–luminol chemiluminescence system. The CLIA detection system was easily integrated with a multifunctional microplate reader and displayed a two to three orders of magnitude dynamic linear detection range from 0.001 to 1, 0.001 to 1, and 0.01 to 1 ng mL−1 for AFB1, FB1 and OTA with 50% inhibitory concentrations (IC50) of 0.01, 0.036, and 0.04 ng mL−1, respectively. The recovery rates are in the range of 63.5 to 121.6% for the three mycotoxins in three kinds of spiked cereal samples. The results of detection in 12 naturally contaminated cereal samples were consistent with that of the classic enzyme-linked immunosorbent assay (ELISA) method. This proposed system is simple, rapid, low cost and high throughput for multiplex mycotoxin assay.