MEI KO

Dr. MEI KO

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2001 in Neuroscience Letters
Verified
Journal Article
Closed access
MKMEI KO
MEI KO
DHDan-Ning Hu
Dan-Ning Hu
RRRobert Ritch
Robert Ritch
SSS.C Sharma
S.C Sharma
CCChau-Fong Chen
Chau-Fong Chen

1 August 2005 in Free Radical Biology and Medicine
Verified
Journal Article
Closed access
MKMEI KO
MEI KO
PPPai-Huei Peng
Pai-Huei Peng
MMMing-Chieh Ma
Ming-Chieh Ma
RRRobert Ritch
Robert Ritch
CCChau-Fong Chen
Chau-Fong Chen

26 August 2010 in Current Eye Research
Verified
Journal Article
Closed access
PDF file
MKMEI KO
MEI KO
PPPai-Huei Peng
Pai-Huei Peng
SHShens-Yao Hsu
Shens-Yao Hsu
CCChau-Fong Chen
Chau-Fong Chen
Purpose: Investigate the effect of dietary vitamin E (Vit E) on the retinas of a rat model of induced glaucoma, in which surgically induced elevation of intraocular pressure (IOP) is associated with an increase in reactive oxygen species. Methods: Rats were fed a standard chow, Vit E-supplemented diet, or Vit E-deficient diet and subjected to surgically induced IOP elevation (or sham surgery) for five weeks. The retinal ganglion cells (RGCs) were subjected to retrograde fluorescent tracer labeling. Results: The mean number of RGCs of rats on the standard chow, Vit E-supplemented diet, and Vit E-deficient diet were 79.6%, 78.6%, and 71.3% of controls, respectively. Lipid peroxidation of the retinas of rats given a Vit E-deficient diet were significantly higher after IOP elevation for three days (14.42 ± 0.25 μM, P = 0.016) and five weeks (10.46 ± 0.11 μM, p = 0.042), compared to rats given standard chow (11.37 ± 0.31 μM; 8.95 ± 0.16 μM). Compared with rats given standard chow, rats given a Vit E-deficient diet had significantly elevated concentrations of glutathione (p = 0.032), but no significant differences in the levels of total superoxide dismutase (SOD), Cu/Zn SOD, or catalase activities three days after IOP elevation. Conclusions: Rats fed a Vit E-deficient diet with surgically induced IOP elevation experience significantly more RGC death than rats fed a normal diet. This phenomenon may be related to the increased level of lipid peroxidation in Vit E-deficient rats.

24 November 2022 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
WLWee Shin Lim
Wee Shin Lim
HHHeng-Yen Ho
Heng-Yen Ho
HHHeng-Chen Ho
Heng-Chen Ho
YCYan-Wu Chen
Yan-Wu Chen
CLChih-Kuo Lee
Chih-Kuo Lee
MKMEI KO
MEI KO
Background: Glaucoma is one of the major causes of blindness; it is estimated that over 110 million people will be affected by glaucoma worldwide by 2040. Research on glaucoma detection using deep learning technology has been increasing, but the diagnosis of glaucoma in a large population with high incidence of myopia remains a challenge. This study aimed to provide a decision support system for the automatic detection of glaucoma using fundus images, which can be applied for general screening, especially in areas of high incidence of myopia. Methods: A total of 1,155 fundus images were acquired from 667 individuals with a mean axial length of 25.60 ± 2.0 mm at the National Taiwan University Hospital, Hsinchu Br. These images were graded based on the findings of complete ophthalmology examinations, visual field test, and optical coherence tomography into three groups: normal (N, n = 596), pre-perimetric glaucoma (PPG, n = 66), and glaucoma (G, n = 493), and divided into a training-validation (N: 476, PPG: 55, G: 373) and test (N: 120, PPG: 11, G: 120) sets. A multimodal model with the Xception model as image feature extraction and machine learning algorithms [random forest (RF), support vector machine (SVM), dense neural network (DNN), and others] was applied. Results: The Xception model classified the N, PPG, and G groups with 93.9% of the micro-average area under the receiver operating characteristic curve (AUROC) with tenfold cross-validation. Although normal and glaucoma sensitivity can reach 93.51% and 86.13% respectively, the PPG sensitivity was only 30.27%. The AUROC increased to 96.4% in the N + PPG and G groups. The multimodal model with the N + PPG and G groups showed that the AUROCs of RF, SVM, and DNN were 99.56%, 99.59%, and 99.10%, respectively; The N and PPG + G groups had less than 1% difference. The test set showed an overall 3%–5% less AUROC than the validation results. Conclusion: The multimodal model had good AUROC while detecting glaucoma in a population with high incidence of myopia. The model shows the potential for general automatic screening and telemedicine, especially in Asia. Trial registration: The study was approved by the Institutional Review Board of the National Taiwan University Hospital, Hsinchu Branch (no. NTUHHCB 108-025-E).

1 September 2000
Verified
Journal Article
Closed access
MKMEI KO
MEI KO
DHD N Hu
D N Hu
RRR Ritch
R Ritch
SSS C Sharma
S C Sharma

1 November 2020 in Chemico-Biological Interactions
Verified
Journal Article
Closed access
HCHsin-Yi Chen
Hsin-Yi Chen
YHYiJung Ho
YiJung Ho
HCHsiu-Chuan Chou
Hsiu-Chuan Chou
ELEn-Chi Liao
En-Chi Liao
YTYi-Ting Tsai
Yi-Ting Tsai
HCHong-Lin Chan
Hong-Lin Chan