Sunghyun So

Mr. Sunghyun So

Yonsei University, Seoul, South Korea
+1

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSSunghyun So
Sunghyun So
NJNakwon Jeong
Nakwon Jeong
ASAran Song
Aran Song
JHJungho Hwang
Jungho Hwang
DKDaehae Kim
Daehae Kim
CLChangyeop Lee
Changyeop Lee
It is important to monitor the temperature and H2O concentration in a large combustion environment in order to improve combustion (and thermal) efficiency and reduce harmful combustion emissions. However, it is difficult to simultaneously measure both internal temperature and gas concentration in a large combustion system because of the harsh environment with rapid flow. In regard, tunable diode laser absorption spectroscopy, which has the advantages of non-intrusive, high-speed response, and in situ measurement, is highly attractive for measuring the concentration of a specific gas species in the combustion environment. In this study, two partially overlapped H2O absorption signals were used in the tunable diode laser absorption spectroscopy (TDLAS) to measure the temperature and H2O concentration in a premixed CH4/air flame due to the wide selection of wavelengths with high temperature sensitivity and advantages where high frequency modulation can be applied. The wavelength regions of the two partially overlapped H2O absorptions were 1.3492 and 1.34927 μm. The measured signals separated the multi-peak Voigt fitting. As a result, the temperature measured by TDLAS based on multi-peak Voigt fitting in the premixed CH4/air flame was the highest at 1385.80 K for an equivalence ratio of 1.00. It also showed a similarity to those tendencies to the temperature measured by the corrected R-type T/C. In addition, the H2O concentrations measured by TDLAS based on the total integrated absorbance area for various equivalent ratios were consistent with those calculated by the chemical equilibrium simulation. Additionally, the H2O concentration measured at an equivalence ratio of 1.15 was the highest at 18.92%.

16 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
SSSunghyun So
Sunghyun So
JPJiyeon Park
Jiyeon Park
ASAran Song
Aran Song
JHJungho Hwang
Jungho Hwang
MYMiyeon Yoo
Miyeon Yoo
CLChangyeop Lee
Changyeop Lee
In a combustion reaction of hydrocarbon fuel, carbon monoxide (CO) is a gas species that is closely related to air pollution generation and combustion efficiency. It has a trade-off with nitrogen oxide and increases rapidly in case of incomplete combustion or in fuel-rich (Φ > 1) environments. Therefore, it is essential to measure CO concentration in order to optimize the combustion condition. In the case of a steel annealing system, the combustion environment is maintained in a deoxidation atmosphere to prevent the formation of an oxide layer on the steel sheet surface. However, it is difficult to measure the CO concentration in a combustion furnace in real-time because of the harsh environment in the furnace. Tunable diode laser absorption spectroscopy, which has the advantages of non-invasiveness, fast response, and in situ measurement-based optical measurement, is highly attractive for measuring the concentration of a certain gas species in a combustion environment. In this study, a combustion system of a partially premixed flamed burner was designed to control the equivalence ratio for fuel-rich conditions. CO concentration was measured using a distributed feedback laser with a wavenumber of 4300.7 cm−1 in the mid-infrared region. The results showed that the CO concentration measured at an equivalence ratio of 1.15 to 1.50 was 0.495% to 6.139%. The detection limit in the combustion environment was analyzed at a path length of 190 cm and an internal temperature of 733 K. The ranges of the peak absorbance were derived as 0.064 and 0.787, which were within the theoretical bounds of 10−3 and 0.80 when the equivalence ratio was varied from 1.15 to 1.50.