2 April 2019 in Energies
Verified
Journal Article
Open access
PDF file
AWArif Widiatmojo
Arif Widiatmojo
SCSasimook Chokchai
Sasimook Chokchai
ITIsao Takashima
Isao Takashima
YUYohei Uchida
Yohei Uchida
KYKasumi Yasukawa
Kasumi Yasukawa
PCPunya Charusiri
Punya Charusiri
The cooling of spaces in tropical regions, such as Southeast Asia, consumes a lot of energy. Additionally, rapid population and economic growth are resulting in an increasing demand for space cooling. The ground-source heat pump has been proven a reliable, cost-effective, safe, and environmentally-friendly alternative for cooling and heating spaces in various countries. In tropical countries, the presumption that the ground-source heat pump may not provide better thermal performance than the normal air-source heat pump arises because the difference between ground and atmospheric temperatures is essentially low. This paper reports the potential use of a ground-source heat pump with horizontal heat exchangers in a tropical country—Thailand. Daily operational data of two ground-source heat pumps and an air-source heat pump during a two-month operation are analyzed and compared. Life cycle cost analysis and CO2 emission estimation are adopted to evaluate the economic value of ground-source heat pump investment and potential CO2 reduction through the use of ground-source heat pumps, in comparison with the case for air-source heat pumps. It was found that the ground-source heat pumps consume 17.1% and 18.4% less electricity than the air-source heat pump during this period. Local production of heat pumps and heat exchangers, as well as rapid regional economic growth, can be positive factors for future ground-source heat pump application, not only in Thailand but also southeast Asian countries.

6 September 2018 in Energies
Verified
Journal Article
Open access
PDF file
SCSasimook Chokchai
Sasimook Chokchai
Srilert ChotpantaratSrilert Chotpantarat
Srilert Chotpantarat
ITIsao Takashima
Isao Takashima
YUYouhei Uchida
Youhei Uchida
AWArif Widiatmojo
Arif Widiatmojo
PCPunya Charusiri
Punya Charusiri
In order to reduce electricity consumption, the vertical loop geothermal heat pump (GHP) system coupled with a normal air conditioner was installed in an experimental room in the Parot Racha Building, Chulalongkorn University, Bangkok, Thailand for a comparative, long-term measurement program. The decrease in electricity consumption was approximately 30%. On the basis of the data derived from our measurements, the underground temperature seemed to be consistent and lower than the average outside air temperature, over two years. The underground system consisted mainly of two 50-m-long drilling wells and pipes with a total length of 170 m. The well performance was not examined, but both soil and groundwater aquifer (Bangkok aquifer) at 25 to 50 m. could be utilized for the cooling operation. Moreover, the major controlling factors of electricity consumption were found to be the outside air temperatures and the underground water circulation temperatures. In addition, we considered the geology, underground temperature, and aquifer of Bangkok concluding that almost all Bangkok areas are suitable for GHP installation, except for those where the subsurface temperature is too high compared with the outside air temperature.

8 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
SRSorranat Ratchawang
Sorranat Ratchawang
Srilert ChotpantaratSrilert Chotpantarat
Srilert Chotpantarat
SCSasimook Chokchai
Sasimook Chokchai
ITIsao Takashima
Isao Takashima
YUYouhei Uchida
Youhei Uchida
PCPunya Charusiri
Punya Charusiri
Ground source heat pump (GSHP) systems have been used worldwide in buildings because of their advantages of highly efficient performance in terms of energy and environment for space cooling and heating; however, cooling demand is predominant in tropical climates. This paper reviews of the GSHP systems applications in Southeast Asia; several applications of GSHP in Thailand, Indonesia, Malaysia, Singapore, and Vietnam have been addressed. Experiments were initiated in 2006 in Kamphaengphet; the latest experiment found in the Scopus searching tool is the GSHP simulation in Kuantan in 2019 using EnergyPlus using the ground loop design software. GSHP systems have the potential to be used in Southeast Asia despite the dominance of cooling demand, leading to a thermal imbalance within the subsurface. This imbalance can reduce the performance of the system; however, groundwater flow is considered as a key factor in preventing the effect of thermal distribution owing to GSHP operation. These results suggest that the GSHP has the potential to reduce emissions and electricity consumption within areas having tropical climates, such as Southeast Asia, for sustainability and future generation.

6 January 2020 in Energies
Verified
Journal Article
Open access
PDF file
YSYutaro Shimada
Yutaro Shimada
YUYouhei Uchida
Youhei Uchida
ITIsao Takashima
Isao Takashima
Srilert ChotpantaratSrilert Chotpantarat
Srilert Chotpantarat
AWArif Widiatmojo
Arif Widiatmojo
KTKoji Tokimatsu
Koji Tokimatsu
The deployment of highly efficient cooling equipment is expected to promote energy savings and greenhouse gas emissions reductions in the tropics. A ground source heat pump (GSHP) has high energy-savings potential for use in Bangkok, Thailand. This study aimed to elucidate the operational conditions of a GSHP when used in Bangkok which was expected to achieve a higher efficiency than an air source heat pump (ASHP) over the long term. An operational experiment on a pilot facility in Bangkok and a simulation over a three-year GSHP operation were conducted. As a result of the operational experiment and simulation, the proposed operational condition was that the 90th percentile value of the hourly heat pump (HP) inlet temperature did not exceed 5 °C above that of the hourly annual ambient temperature during the third year of operation. When a GSHP designed based on this condition was utilized for a small government building, the required number of boreholes were 24, 4, and 3 for air-conditioned areas of 200, 40, and 25 m2, respectively, which achieved 40% energy savings. Thus, a small-scale GSHP in Bangkok designed based on the proposed condition can achieve high efficiency within space limitations.

15 August 2020 in Preprints.org
Verified
Preprint
Open access
PDF file
DYDwi Fitri Yudiantoro
Dwi Fitri Yudiantoro
BIBambang Agus Irawan
Bambang Agus Irawan
IHIntan Paramita Haty
Intan Paramita Haty
DSDewi Sri Sayudi
Dewi Sri Sayudi
ASArum Suproboriniaru
Arum Suproboriniaru
ITIsao Takashima
Isao Takashima
The Ijen volcano has Pleistocene age (294.00 ± 0.03 Ma), and this stratovolcano was very acidic crater water with a pH of 0-1. The acidic crater water seeps into the Banyupait river flow. Asembagus is a research area located on the northern slope of the Ijen volcano, and the Banyupait River drains this. The acidic river water flows from the Ijen Crater Lake, so the pH of the water river was very acidic. This study used several different analytic methodologies with some previous researchers, namely using the method of geological mapping, pH measurement, spectrophotometry, IRMS (Isotope Ratio Mass Spectrometer), and the technique of Induced Coupled Mass Spectrometry (ICP-MS). Besides, the petrographic analysis is used to determine the composition of rock minerals due to rocks interacting with acidic water. Banyupait River water in the Asembagus area has a pH of river water around 3-7.3, SO4 (220-683 ppm), and the type of water is meteoric water. Also, concentrations of Ca, K, Mg in the west Banyupait river irrigation water flow showed higher levels when compared to the eastern Banyupait River water flow. Likewise, REE elements from the Asembagus region showed lower concentrations compared to Ijen Crater water. This change in the level of chemical elements is caused by the acidity of the Banyupait River being diluted or mixed with water from other water. However, the spring was not affected by acidic water. The process of acidic water interaction with rocks can also be observed from rocks traversed by the Banyupait River flow. Chalcedony and hematite replace the primary minerals of basaltic rocks. This research is expected to improve the quality of water needed by the Asembagus community so that people can live healthily.