Aiming at the problem of low accuracy of robot joint fault diagnosis, a fault diagnosis method of robot joint based on BP neural network is designed. In this paper, the UR10 robot is taken as the research object, and the end pose data of the robot are collected in real time. By injecting different joint errors and changing the sampling frequency, the joint fault database is collected and established, and the BP neural network is used for training to obtain the robot neural network fault diagnosis model. The fault diagnosis model can output the joint fault of the input end pose data. And we analyzed the influence of different joint angle errors and different training sets on the accuracy of joint fault diagnosis of the robot. The results show that when the sampling frequency is 250 Hz, the simulation result of joint fault diagnosis accuracy with the fault degree of 0.5° is 99.17%, and the experimental result is 97.87%. Compared with traditional data-driven methods, it has higher accuracy and diagnostic efficiency, and compared with existing machine learning methods, it also achieves a high accuracy while reducing the network complexity. The effectiveness of the BP neural network robot joint fault diagnosis method is verified by experiments.
As an important index to quantitatively measure the motion performance of a manipulator, motion reliability is affected by many factors, such as joint clearance. The present research utilized a UR10 manipulator as the research object. A factor mapping model for influencing the motion reliability was established. The link flexibility factor, joint flexibility factor, joint clearance factor, and Denavit–Hartenberg (DH) parameters were comprehensively considered in this model. The coupling relationship among the various factors was concisely expressed. Subsequently, the nonlinear response surface method was used to calculate the reliability and sensitivity of the manipulator, which provided an applicable reference for its trajectory planning and motion control. In addition, a data-driven fault diagnosis method based on the kernel principal component analysis (KPCA) was used to verify the motion accuracy and sensitivity of the manipulator, and joint rotation failure was considered as an example to verify the accuracy of the KPCA method. This study on the motion reliability of the manipulator is of great significance for the current motion performance, adjusting the control strategy and optimizing the completion effect of the motion task of a manipulator.
6 January 2021 in International Journal of Computer Assisted Radiology and Surgery