Victor Bocos-Bintintan

Dr. Victor Bocos-Bintintan

Faculty of Environmental Science & Engineering, Babes-Bolyai University, Str. Fantanele 30, Cluj-Napoca, RO 400294, Romania
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2009 in International Journal for Ion Mobility Spectrometry
Verified
Journal Article
Closed access
PDF file
GKGushinder Kaur-Atwal
Gushinder Kaur-Atwal
GOGavin O’connor
Gavin O’connor
AAAlexander A. Aksenov
Alexander A. Aksenov
VBVictor Bocos-Bintintan
Victor Bocos-Bintintan
CTC. L. Paul Thomas
C. L. Paul Thomas
CCColin S. Creaser
Colin S. Creaser

12 September 2011 in Journal of Breath Research
Verified
Journal Article
Closed access
RHR Huo
R Huo
Agapios AgapiouAgapios Agapiou
Agapios Agapiou
VBVictor Bocos-Bintintan
Victor Bocos-Bintintan
LBL J Brown
L J Brown
CBC Burns
C Burns
CTC L P Thomas
C L P Thomas
This experiment observed the evolution of metabolite plumes from a human trapped in a simulation of a collapsed building. Ten participants took it in turns over five days to lie in a simulation of a collapsed building and eight of them completed the 6 h protocol while their breath, sweat and skin metabolites were passed through a simulation of a collapsed glass-clad reinforced-concrete building. Safety, welfare and environmental parameters were monitored continuously, and active adsorbent sampling for thermal desorption GC-MS, on-line and embedded CO, CO(2) and O(2) monitoring, aspirating ion mobility spectrometry with integrated semiconductor gas sensors, direct injection GC-ion mobility spectrometry, active sampling thermal desorption GC-differential mobility spectrometry and a prototype remote early detection system for survivor location were used to monitor the evolution of the metabolite plumes that were generated. Oxygen levels within the void simulator were allowed to fall no lower than 19.1% (v). Concurrent levels of carbon dioxide built up to an average level of 1.6% (v) in the breathing zone of the participants. Temperature, humidity, carbon dioxide levels and the physiological measurements were consistent with a reproducible methodology that enabled the metabolite plumes to be sampled and characterized from the different parts of the experiment. Welfare and safety data were satisfactory with pulse rates, blood pressures and oxygenation, all within levels consistent with healthy adults. Up to 12 in-test welfare assessments per participant and a six-week follow-up Stanford Acute Stress Response Questionnaire indicated that the researchers and participants did not experience any adverse effects from their involvement in the study. Preliminary observations confirmed that CO(2), NH(3) and acetone were effective markers for trapped humans, although interactions with water absorbed in building debris needed further study. An unexpected observation from the NH(3) channel was the suppression of NH(3) during those periods when the participants slept, and this will be the subject of further study, as will be the detailed analysis of the casualty detection data obtained from the seven instruments used.

10 February 2010 in Analytical Chemistry
Verified
Journal Article
Open access
JRJames C Reynolds
James C Reynolds
GBG. J. Blackburn
G. J. Blackburn
CGC. Guallar-Hoyas
C. Guallar-Hoyas
VMV. H. Moll
V. H. Moll
VBVictor Bocos-Bintintan
Victor Bocos-Bintintan
CTC. L. P. Thomas
C. L. P. Thomas
A thermal desorption unit has been interfaced to an electrospray ionization-ion mobility-time-of-flight mass spectrometer. The interface was evaluated using a mixture of six model volatile organic compounds which showed detection limits of <1 ng sample loaded onto a thermal desorption tube packed with Tenax, equivalent to sampled concentrations of 4 μg L−1. Thermal desorption profiles were observed for all of the compounds, and ion mobility-mass spectrometry separations were used to resolve the probe compound responses from each other. The combination of temperature programmed thermal desorption and ion mobility improved the response of selected species against background ions. Analysis of breath samples resulted in the identification of breath metabolites, based on ion mobility and accurate mass measurement using siloxane peaks identified during the analysis as internal lockmasses.

1 August 2017 in Analytica Chimica Acta
Verified
Journal Article
Closed access
Ileana Andreea RatiuIleana Andreea Ratiu
Ileana Andreea Ratiu
VBVictor Bocos-Bintintan
Victor Bocos-Bintintan
APAdrian Patrut
Adrian Patrut
VMVictor Hugo Moll
Victor Hugo Moll
MTMatthew Turner
Matthew Turner
CTC.L. Paul Thomas
C.L. Paul Thomas

24 July 2017 in Bioanalysis
Verified
Journal Article
Closed access
Ileana Andreea RatiuIleana Andreea Ratiu
Ileana Andreea Ratiu
TLTomasz Ligor
Tomasz Ligor
VBVictor Bocos-Bintintan
Victor Bocos-Bintintan
Bogusław BuszewskiBogusław Buszewski
Bogusław Buszewski
Bacteria are the main cause of many human diseases. Typical bacterial identification methods, for example culture-based, serological and genetic methods, are time-consuming, delaying the potential for an early and accurate diagnosis and the appropriate subsequent treatment. Nevertheless, there is a stringent need for in situ tests that are rapid, noninvasive and sensitive, which will greatly facilitate timely treatment of the patients. This review article presents volatile organic metabolites emitted from various micro-organism strains responsible for common bacterial infections in humans. Additionally, the manuscript shows the application of different analytical techniques for fast bacterial identification. Details of these techniques are given, which focuses on their advantages and drawbacks in using for volatile organic components analysis.

12 September 2019 in Critical Reviews in Analytical Chemistry
Verified
Journal Article
Closed access
Ileana Andreea RatiuIleana Andreea Ratiu
Ileana Andreea Ratiu
VBVictor Bocos-Bintintan
Victor Bocos-Bintintan
FMFernanda Monedeiro
Fernanda Monedeiro
Maciej Monedeiro-MilanowskiMaciej Monedeiro-Milanowski
Maciej Monedeiro-Milanowski
TLTomasz Ligor
Tomasz Ligor
Bogusław BuszewskiBogusław Buszewski
Bogusław Buszewski
Simple tests using sniff analysis that have the ability of diagnosing and rapidly distinguishing between infections due to different bacteria are urgently required by medical community worldwide. Professionals interested in this topic wish for these tests to be simultaneously cheap, fast, easily applicable, non-invasive, robust, reliable, and sensitive. Current analytical instrumentation has already the ability for performing real time (minutes or a few dozens of minutes) analysis of volatile bacterial biomarkers (the VOCs emitted by bacteria). Although many articles are available, a review displaying an objective evaluation of the current status in the field is still needed. This review tries to present an overview regarding the bacterial biomarkers released from in vitro cultivation of various bacterial strains and also from different biological matrices investigated, over the last 10 years. We have described results of relevant studies, which used modern analytical techniques to evaluate specific biomarker profiles associated with bacterial infections. Our purpose was to present a comprehensive view of available possibilities for detection of emitted bacterial VOCs from different matrices. We intend that this review to be of general interest for both medical doctors and for all researchers preoccupied with bacterial infectious diseases and their rapid diagnosis using analytical instrumentation.