Joanna Taczała

Ms. Joanna Taczała

Institute of Materials Science and Engineering, Lodz University of Technology,
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2020 in Materials
Verified
Journal Article
Open access
PDF file
JTJoanna Taczała
Joanna Taczała
Jacek SawickiJacek Sawicki
Jacek Sawicki
Joanna PietrasikJoanna Pietrasik
Joanna Pietrasik
The mechanical properties of dental acrylic resins have to be improved in the case of a thin denture plate. This can be achieved by cellulose addition, playing the role of active filler. But to provide the excellent dispersion of cellulose microfibres within the hydrophobic polymer matrix, its surface has to be modified. Cellulose microfibres with average length from 8 to 30 μm were modified with octyltriethoxysilane and (3-methacryloxypropyl)methyldimethoxysilane. The latter also participated in the polymerisation reaction of methyl methacrylate. Dental composites were prepared following the general procedure provided by the supplier. The successful modification of the microfibres led to the improved compatibility of the cellulose and poly(methyl methacrylate). The fibres after modification were uniformly distributed within the matrix, resulting in the improved mechanical performance of obtained materials. Cellulose microfibres are good candidates for the dental materials to be used as the active filler. The simple and straightforward approach for the cellulose modifications with silanes provides good potential for its future practical application.

2 September 2018 in Journal of Achievements in Materials and Manufacturing Engineering
Verified
Journal Article
Closed access
JTJoanna Taczała
Joanna Taczała
Jacek SawickiJacek Sawicki
Jacek Sawicki
Purpose: The purpose of this paper is to analyse attempts at improving the bond between acrylic artificial teeth and the denture base plate - considered in the context of single incisors in framework denture. Design/methodology/approach: It is a review article focusing on the analysis of state of the art in the field of the bond between the polymerised acrylic (teeth) and the polymerising acrylic resin during the production of denture (denture plate). Previous works regard the issue of individual incisor teeth (both upper and lower) breaking off from the metal partial denture. Findings: The bond between artificial acrylic teeth and the acrylic denture plate of the prosthesis was discussed. Ways of improving this bond were also presented. Although researchers and companies offer many methods for improving this bond, none of them refer directly to the issue discussed in this article. In conclusion- the hitherto scientific achievements work well in the case of acrylic prostheses without a metal frame, which constitutes an obstacle for achieving the effect required. In this work, it is suggested that further research would not only develop and provide more detail on the issue of the bond between artificial teeth and the denture plate, but also solve the problem appearing in cases of metal partial denture. Originality/value: This article shows a significant problem that hasn’t been discussed in detail in the past.

1 February 2023 in Archives of Materials Science and Engineering
Verified
Journal Article
Closed access
JTJoanna Taczała
Joanna Taczała
SPSylwester Pawęta
Sylwester Pawęta
The purpose of this article was to present in a concise and organized way the available knowledge about ferritic nitrocarburizing in low-pressure. The authors aimed to indicate the research gap, and the whole article is a starting point for further research.The research method was the analysis of available literature, patent database and industry notes from manufacturers of modern furnaces.The ferritic nitrocarburizing process has many advantages in line with the market demand and the lack of solutions. The article summarizes the knowledge in the field of the ferritic nitrocarburizing process as a systematization of knowledge and a starting point for further research.The information described in the article requires further laboratory research.The information collected by the authors was the basis for developing the technology discussed in the LIDER/3/0025/L-12/20/NCBR/2021 project.Research on this type of treatment will enable the development of technology and will meet the expectations and needs of the industry. It will also provide benefits in the form of a better understanding of the processes and the determination of the relationship between the parameters and the properties of the obtained surface layers.

14 July 2021 in Materials
Verified
Journal Article
Open access
PDF file
JTJoanna Taczała
Joanna Taczała
KRKatarzyna Rak
Katarzyna Rak
Jacek SawickiJacek Sawicki
Jacek Sawicki
MKMichał Krasowski
Michał Krasowski
The creation of acrylic dentures involves many stages. One of them is to prepare the surfaces of artificial teeth for connection with the denture plates. The teeth could be rubbed with a chemical reagent, the surface could be developed, or retention hooks could be created. Preparation of the surface is used to improve the bond between the teeth and the plate. Choosing the right combination affects the length of denture use. This work focuses on a numerical analysis of grooving. The purpose of this article is to select the shape and size of the grooves that would most affect the quality of the bond strength. Two types of grooves in different dimensional configurations were analyzed. The variables were groove depth and width, and the distance between the grooves. Finally, 24 configurations were obtained. Models were analyzed in terms of their angular position to the loading force. Finite element method (FEM) analysis was performed on the 3D geometry created, which consisted of two polymer bodies under the shear process. The smallest values of the stresses and strains were characterized by a sample with parallel grooves with the grooving dimensions width 0.20 mm, thickness 0.10 mm, and distance between the grooves 5.00 mm, placed at an angle of 90°. The best dimensions from the parallel (III) and cross (#) grooves were compared experimentally. Specimens with grooving III were not damaged in the shear test. The research shows that the shape of the groove affects the distribution of stresses and strains. Combining the selected method with an adequately selected chemical reagent can significantly increase the strength of the connection.


Verified
Journal Article
Open access
PDF file
JTJoanna Taczała
Joanna Taczała
Jacek SawickiJacek Sawicki
Jacek Sawicki
MKMichał Krasowski
Michał Krasowski
JSJerzy Sokołowski
Jerzy Sokołowski
Patients who require dental prosthetic restoration using frame dentures in the front part of the mouth very frequently report that teeth fall out of their dentures. However, the available scientific papers are insufficient to compare the various methods of improving the connection between the denture base and the artificial tooth and choosing the best solution. This paper focuses on providing all parameters, enabling the reproduction of tests, and accounting for all variables. The paper uses an original method of creating grooves, sandpaper, sandblasting, and cutting the acrylate layer with a burr in one and two directions. Developed surfaces were additionally subjected to detailed examination. This study used 180 specimens divided into three groups and subjected to various environments (dry, artificial saliva, and thermocycles). Shearing and tensile strength tests were performed. The best results were obtained with a carbide burr. The increase in connection durability was as follows in the case of the shear test: 116.47% in dry samples, 155.38% in samples soaked in artificial saliva, and 46.59% in samples after thermocycles. The increase in tensile resistance was: 198.96% in a dry environment, 88.10% before being soaked in artificial saliva, and 94.04% after thermocycles.