In this study, a single stage thermoelectric cooler (TER, of size: 21 × 14.2 × 13.5 cm) with thermoelectric module (TEM, of type inbc1-127. 05 with size 40 × 40 × 4.0 mm) and applied electrical power of 30 W and current of 2.5 A, was adopted to estimate the coefficient of performance (COP) of thermoelectric refrigerator (TER). The TER uses a fan to cool the heat exchange region of the TEM. The temperature of the fruit/vegetable samples used in this study was taken before and after cooling for a specific period. The temperatures at both the hot and cold sides of the TEM were also taken at every specific cooling period. The experimented TER can cool vegetable/fruit from about 27 to 5°C within 3 h. The aim of this study is to determine the COP of TER to ascertain the possible applications. The temperature gradient at the heat exchange section of TEM was used to estimate the average theoretical COP to be 0.99, the heat extracted from the cooling chamber and the power supplied was used to estimate the average practical cooling COP to be 0.52; which is within 0.4–0.7 standard COP for a single stage type of TER.
1 March 2021 in Journal of Material Cycles and Waste Management
Waste-to-energy (WTE) management method, has been considered as the best option; because, it reduces the quantity of waste generated by about 71 %, and ensure energy recovery for efficient waste management. In this study, physical, chemical and the heating properties of the waste components, generated in Ilorin were determined. The heating value was modelled against the physicochemical properties of MSW components to ascertain their correlation. The electrical power rating potential of the MSW was determined using Dulong’s model. The regression model developed on the correlation analysis was used to predict the effect of the physicochemical properties on the heating value and the power generation potential. It was concluded that 1 % increase in fixed carbon and volatile matter, total carbon and Nitrogen content, increases electrical power rating by 8 %, 37 %, 21 % and 10.80 % respectively; while 1 % increase in moisture and hydrogen content, reduces the electrical power rating by 11 % and 69.3 % respectively.
In energy recovery technology, via municipal solid waste (MSW) as an energy resource; the capacity of the power plant required can be designed, if the potentials of the heat and electrical energy of the waste to be combusted has been established. Conversely, in this research, the amount of power potential of the waste required as fuel, is determined through the design for the capacity of the steam power plant that will utilize municipal solid waste as an energy resource. The capacity of the power plant is designed, using single reheat Rankine cycle. The pressure and temperature selected for the design of the boiler is 30 bar and 400 °C, the pressure at the reheat tube is 6 bar, and the pressure at the condenser is 0.032 bar. The heat supplied to the boiler is calculated to be 3639.2 kJ/kg, the total work-output of the turbine is 1451.4 kJ/kg and the heat rejected at the condenser is 2187.6 kJ/kg. The quantity of MSW required is predicted to be 418 MJ/kg based on the calorific value of 20 MJ/kg, and its heat energy and electrical power potentials is predicted to be 2.3 GWh and 29 MW respectively while the grid to power is 20 MW.