Ryszard Zwierzchowski

Dr. Ryszard Zwierzchowski

associated professor
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2022 in Energy
Verified
Journal Article
Open access
FAFahad Alkasmoul
Fahad Alkasmoul
MAMohammed Asaker
Mohammed Asaker
AWAleksander Widuch
Aleksander Widuch
MMMarcin Malicki
Marcin Malicki
RZRyszard Zwierzchowski
Ryszard Zwierzchowski
MWMarcin Wołowicz
Marcin Wołowicz

7 November 2017 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
RZRyszard Zwierzchowski
Ryszard Zwierzchowski
In District Heating Systems (DHS) there are significant fluctuations in demand for heat by consumers during both the heating and the summer seasons. These variations are considered primarily in the 24-hour time horizon. These problems are aggravated further if the DHS is supplied by a CHP plant, because fluctuations in heat demand adversely affect to a significant degree the stable production of electricity at high overall efficiency. Therefore, introducing Thermal Energy Storage (TES) would be highly recommended on these grounds alone. The characteristics of Large (i.e. over 10 000 m3) TES in operation in Poland are presented. Information is given regarding new projects (currently in design or construction) that apply TES technology in DHS in Poland. The paper looks at the methodology used in Poland to select the TES system for a particular DHS, i.e., procedure for calculating capacity of the TES tank and the system to prevent water stored in the tank from absorbing oxygen from atmospheric air. Implementation of TES in DHS is treated as a recommended technology in the Polish District Heating sector. This technology offers great opportunities to improve the operating conditions of DHS, cutting energy production costs and emissions of pollutants to the atmosphere.

23 February 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
RZRyszard Zwierzchowski
Ryszard Zwierzchowski
ONOlgierd Niemyjski
Olgierd Niemyjski
This paper deals with different operating conditions of a District Heating and Cooling (DHC) System and its influence on heat transportation losses of a District Heating Network (DHN). The different operating conditions of the DHC System's mean different flow rate and temperature of the network water flowing in the DHN. These different operating conditions of the DHC System result in the DHNs having variable transportation losses. The analyzed DHC System consists of the Heat Only Boilers (HOB) plant and the DHN with substations and chambers. The DHNs in Poland are usually installed as underground, traditionally insulated piping placed in concrete ducts (large diameter and main pipelines) or pre-insulated piping placed directly in the ground. The result of the analysis was used to verify calculation methods of fluid flow and heat transportation losses of the DHN, when cold for consumers is generated using either absorption or adsorption chillers. The total heat transportation losses of the DHN differ according to individual systems and depend on the size of the DHC System, its heating loads and quality of insulation of the piping. This paper presents the results of the numerical calculation of the temperature distribution in the soil around the piping channel using an FDA model. The results of the numerical simulation of water and heat flow through the DHN allow to determine the total heat transportation losses of the DHN for different operating conditions of the DHC System.

16 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
RZRyszard Zwierzchowski
Ryszard Zwierzchowski
MWMarcin Wołowicz
Marcin Wołowicz
The paper contains a simplified energy and exergy analysis of pumps and pipelines system integrated with Thermal Energy Storage (TES). The analysis was performed for a combined heat and power plant (CHP) supplying heat to the District Heating System (DHS). The energy and exergy efficiency for the Block Part of the Siekierki CHP Plant in Warsaw was estimated. CHP Plant Siekierki is the largest CHP plant in Poland and the second largest in Europe. The energy and exergy analysis was executed for the three different values of ambient temperature. It is according to operation of the plant in different seasons: winter season (the lowest ambient temperature Tex = −20 °C, i.e., design point conditions), the intermediate season (average ambient temperature Tex = 1 °C), and summer (average ambient temperature Tex = 15 °C). The presented results of the analysis make it possible to identify the places of the greatest exergy destruction in the pumps and pipelines system with TES, and thus give the opportunity to take necessary improvement actions. Detailed results of the energy-exergy analysis show that both the energy consumption and the rate of exergy destruction in relation to the operation of the pumps and pipelines system of the CHP plant with TES for the tank charging and discharging processes are low.

8 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
ONOlgierd Niemyjski
Olgierd Niemyjski
RZRyszard Zwierzchowski
Ryszard Zwierzchowski
This paper explores how water temperature changes in a district heating system (DHS) impact the monitoring of water losses. Water volume in DHS is constantly monitored, recorded, and replenished. The leakage and failure status of the DHS is often monitored through measuring the make-up water flow rate. In this paper, we present the methodology and a simplified model of the dynamics of the heating system operation, which was used to determine the profile of changes in the average temperature and density of water in the system. The mathematical model of the district heating network (DHN) was verified by comparing the results of simulation calculations, i.e., calculated values of the temperature of water returning to the heat source, with the measured values. Fluctuations in water temperature cause changes in the density and volume of water in the DHN, which affect the amount of water supplementing the system. This is particularly noticeable in a DHN with a large water volume. The study reports an analysis of measurement results of operating parameters of a major DHS in Poland (city of Szczecin). Hourly measurements were made of supply and return water temperature, water flow rate, and pressure throughout the whole of 2019. The water volume of the analyzed DHN is almost 42,000 m3 and the changes in water volume per hour are as high as 5 m3/h, representing 20–30% of the value of the make-up water flow rate. The analysis showed that systems for monitoring the tightness of the DHS and detecting failures, on the basis of measurements of the make-up water flow rate, should take into account the dynamics of water volume changes in the DHN.

19 September 2021 in Archives of Environmental Protection
Verified
Journal Article
Closed access
RZRyszard Zwierzchowski
Ryszard Zwierzchowski
EREwelina Różycka-Wrońska
Ewelina Różycka-Wrońska
This study describes the correlation between emission of gaseous pollutants to the atmosphere and the combustion parameters of a coal-fired 25 MW heating capacity water boiler with mechanical grate (boiler type WR-25) in unstable working conditions: start-up, shutdown and loads below the technical minimum. Whereas measurements were made for a specific type and size of coal-fired water boiler with mechanical grate, the measurements and calculations are applicable to WR boilers with a different heating power as well as OR type steam boilers, which have a practically identical design. In sum, there are more than 1,000 coal-fired water and steam boilers of these types in Poland. In addition, the analysis reported in this paper highlights the important role played by boilers operating in unstable conditions in terms of emission of gaseous pollutants to the atmosphere. The conclusions are relevant for other boilers fi red with gas, oil or biomass operating under conditions such as start-up, shutdown and loads below the technical minimum. This article fi lls a gap in air protection engineering practice and the literature with regard to indicators and emission standards, drawing on measurements of pollutant concentrations in the exhaust gases from unstable WR boiler working conditions. The measurements can be used to assess the emission of pollutants to the atmosphere in such boiler working conditions and their impact on air quality. The analyses presented were based on the authors’ own measurements in WR-25 boiler technical installations using portable gas analyser GASMET DX-4000, which uses the FT-IR measurement method for compounds such as SO2, NOx, HCl, HF, NH3, CH4, and CO. Concentrations of CO, NOx and SO2 in exhaust gases were determined with multiple regression with the STATISTICA statistical software and with linear regression complemented by the “smart” package in the MATLAB environment. The study provides computational models to identify pollutant concentrations in the exhaust gases in any working conditions of WR-25 boilers