Yang Li

Dr. Yang Li


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2014 in Sensors
Verified
Journal Article
Open access
PDF file
FWFangfang Wang
Fangfang Wang
JTJianhua Tong
Jianhua Tong
YLYang Li
Yang Li
Bian ChaoBian Chao
Bian Chao
SJSun Jizhou
Sun Jizhou
SXShanhong Xia
Shanhong Xia
This work describes the fabrication, characterization, and application of a gold microband array electrode (MAE) for the determination of phosphate in fresh water samples. The working principle of this MAE is based on the reduction of a molybdophosphate complex using the linear sweep voltammetric (LSV) method. The calibration of this microsensor was performed with standard phosphate solutions prepared with KH2PO4 and pH adjusted to 1.0. The microsensor consists of a platinum counter electrode, a gold MAE as working electrode, and an Ag/AgCl electrode as reference electrode. The microelectrode chips were fabricated by the Micro Electro-Mechanical System (MEMS) technique. To improve the sensitivity, gold nanoparticles (AuNPs) were electrodeposited on the working electrode. With a linear range from 0.02 to 0.50 mg P/L, the sensitivity of the unmodified microsensor is 2.40 µA per (mg P/L) (R2 = 0.99) and that of the AuNPs-modified microsensor is 7.66 µA per (mg P/L) (R2 = 0.99). The experimental results showed that AuNPs-modified microelectrode had better sensitivity and a larger current response than the unmodified microelectrode.

26 December 2014 in Sensors
Verified
Journal Article
Open access
PDF file
JWJinfen Wang
Jinfen Wang
Bian ChaoBian Chao
Bian Chao
JTJianhua Tong
Jianhua Tong
SJSun Jizhou
Sun Jizhou
YLYang Li
Yang Li
SXShanhong Xia
Shanhong Xia
This paper investigated two different modification methods of graphene (GN) on ultramicroelectrode array (UMEA) and applied the GN modified UMEA for the determination of dissolved oxygen (DO). The UMEAs were fabricated by Micro Electro-Mechanical System (MEMS) technique and the radius of each ultramicroelectrode is 10 μm. GN-NH2 and GN-COOH were modified on UMEA by using self-assembling method. Compared with GN-NH2 modified UMEA, the GN-COOH modified UMEA showed better electrochemical reduction to DO, owing to better dispersing and more active sites. The GN-COOH on UMEA was electroreduced to reduced GN-COOH (rGN-COOH) to increase the conductivity and the catalysis performance. Finally, the palladium nanoparticles/rGN-COOH composite was incorporated into DO microsensor for the detection of DO.