Riad Abou Zahr

Dr. Riad Abou Zahr


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
SRSurendranath Reddy Veeram Reddy
Surendranath Reddy Veeram Reddy
YAYousef Arar
Yousef Arar
RZRiad Abou Zahr
Riad Abou Zahr
VGVasu Gooty
Vasu Gooty
JHJennifer Hernandez
Jennifer Hernandez
THTarique Hussain
Tarique Hussain
Today’s standard of care, in the congenital heart disease (CHD) population, involves performing cardiac catheterization under x-ray fluoroscopy and cardiac magnetic resonance (CMR) imaging separately. The unique ability of CMR to provide real-time functional imaging in multiple views without ionizing radiation exposure has the potential to be a powerful tool for diagnostic and interventional procedures. Limiting fluoroscopic radiation exposure remains a challenge for pediatric interventional cardiologists. This pilot study’s objective is to establish feasibility of right (RHC) and left heart catheterization (LHC) during invasive CMR (iCMR) procedures at our institution in the CHD population. Furthermore, we aim to improve simultaneous visualization of the catheter balloon tip, MR-conditional guidewire, and cardiac/vessel anatomy during iCMR procedures. Subjects with CHD were enrolled in a pilot study for iCMR procedures at 1.5 T with an MR-conditional guidewire. The CMR area is located adjacent to a standard catheterization laboratory. Using the interactive scanning mode for real-time control of the imaging location, a dilute gadolinium-filled balloon-tip catheter was used in combination with an MR-conditional guidewire to obtain cardiac saturations and hemodynamics. A recently developed catheter tracking technique using a real-time single-shot balanced steady-state free precession (bSSFP), flip angle (FA) 35–45°, echo time (TE) 1.3 ms, repetition time (TR) 2.7 ms, 40° partial saturation (pSAT) pre-pulse was used to visualize the gadolinium-filled balloon, MR-conditional guidewire, and cardiac structures simultaneously. MR-conditional guidewire visualization was enabled due to susceptibility artifact created by distal markers. Pre-clinical phantom testing was performed to determine the optimum imaging FA-pSAT combination. The iCMR procedure was successfully performed to completion in 31/34 (91%) subjects between August 1st, 2017 to December 13th, 2018. Median age and weight were 7.7 years and 25.2 kg (range: 3 months – 33 years and 8 – 80 kg). Twenty-one subjects had single ventricle (SV) anatomy: one subject was referred for pre-Glenn evaluation, 11 were pre-Fontan evaluations and 9 post-Fontan evaluations for protein losing enteropathy (PLE) and/or cyanosis. Thirteen subjects had bi-ventricular (BiV) anatomy, 4 were referred for coarctation of the aorta (CoA) evaluations, 3 underwent vaso-reactivity testing with inhaled nitric oxide, 3 investigated RV volume dimensions, two underwent branch PA stenosis evaluation, and the remaining subject was status post heart transplant. No catheter related complications were encountered. Average time taken for first pass RHC, LHC/aortic pull back, and to cross the Fontan fenestration was 5.2, 3.0, and 6.5 min, respectively. Total success rate to obtain required data points to complete Fick principle calculations for all patients was 331/337 (98%). Subjects were transferred to the x-ray fluoroscopy lab if further intervention was required including Fontan fenestration device closure, balloon angioplasty of pulmonary arteries/conduits, CoA stenting, and/or coiling of aortopulmonary (AP) collaterals. Starting with subject #10, an MR-conditional guidewire was used in all subsequent subjects (15 SV and 10 BiV) with a success rate of 96% (24/25). Real-time CMR-guided RHC (25/25 subjects, 100%), retrograde and prograde LHC/aortic pull back (24/25 subjects, 96%), CoA crossing (3/4 subjects, 75%) and Fontan fenestration test occlusion (2/3 subjects, 67%) were successfully performed in the majority of subjects when an MR-conditional guidewire was utilized. Feasibility for detailed diagnostic RHC, LHC, and Fontan fenestration test occlusion iCMR procedures in SV and BiV pediatric subjects with complex CHD is demonstrated with the aid of an MR-conditional guidewire. A novel real-time pSAT GRE sequence with optimized FA-pSAT angle has facilitated simultaneous visualization of the catheter balloon tip, MR-conditional guidewire, and cardiac/vessel anatomy during iCMR procedures.

4 January 2021 in Pediatric Cardiology
Verified
Journal Article
Open access
PDF file
ATAnimesh Tandon
Animesh Tandon
NMNavina Mohan
Navina Mohan
CJCory Jensen
Cory Jensen
BBBarbara Elisabeth Ursula Burkhardt
Barbara Elisabeth Ursula Burkhardt
VGVasu D. Gooty
Vasu D. Gooty
THTarique Hussain
Tarique Hussain
Ventricular contouring of cardiac magnetic resonance imaging is the gold standard for volumetric analysis for repaired tetralogy of Fallot (rTOF), but can be time-consuming and subject to variability. A convolutional neural network (CNN) ventricular contouring algorithm was developed to generate contours for mostly structural normal hearts. We aimed to improve this algorithm for use in rTOF and propose a more comprehensive method of evaluating algorithm performance. We evaluated the performance of a ventricular contouring CNN, that was trained on mostly structurally normal hearts, on rTOF patients. We then created an updated CNN by adding rTOF training cases and evaluated the new algorithm’s performance generating contours for both the left and right ventricles (LV and RV) on new testing data. Algorithm performance was evaluated with spatial metrics (Dice Similarity Coefficient (DSC), Hausdorff distance, and average Hausdorff distance) and volumetric comparisons (e.g., differences in RV volumes). The original Mostly Structurally Normal (MSN) algorithm was better at contouring the LV than the RV in patients with rTOF. After retraining the algorithm, the new MSN + rTOF algorithm showed improvements for LV epicardial and RV endocardial contours on testing data to which it was naïve (N = 30; e.g., DSC 0.883 vs. 0.905 for LV epicardium at end diastole, p < 0.0001) and improvements in RV end-diastolic volumetrics (median %error 8.1 vs 11.4, p = 0.0022). Even with a small number of cases, CNN-based contouring for rTOF can be improved. This work should be extended to other forms of congenital heart disease with more extreme structural abnormalities. Aspects of this work have already been implemented in clinical practice, representing rapid clinical translation. The combined use of both spatial and volumetric comparisons yielded insights into algorithm errors.

1 March 2021 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
YAYousef Arar
Yousef Arar
THTarique Hussain
Tarique Hussain
RZRiad Abou Zahr
Riad Abou Zahr
VGVasu D. Gooty
Vasu D. Gooty
JGJoshua S. Greer
Joshua S. Greer
SRSurendranath Reddy Veeram Reddy
Surendranath Reddy Veeram Reddy
Cardiac catheterization and cardiovascular magnetic resonance (CMR) imaging have distinct diagnostic roles in the congenital heart disease (CHD) population. Invasive CMR (iCMR) allows for a more thorough assessment of cardiac hemodynamics at the same time under the same conditions. It is assumed but not proven that iCMR gives an incremental value by providing more accurate flow quantification. Subjects with CHD underwent real-time 1.5 T iCMR using a passive catheter tracking technique with partial saturation pulse of 40° to visualize the gadolinium-filled balloon, CMR-conditional guidewire, and cardiac structures simultaneously to aid in completion of right (RHC) and left heart catheterization (LHC). Repeat iCMR and catheterization measurements were performed to compare reliability by the Pearson (PCC) and concordance correlation coefficients (CCC). Thirty CHD (20 single ventricle and 10 bi-ventricular) subjects with a median age and weight of 8.3 years (2–33) and 27.7 kg (9.2–80), respectively, successfully underwent iCMR RHC and LHC. No catheter related complications were encountered. Time taken for first pass RHC and LHC/aortic pull back was 5.1, and 2.9 min, respectively. Total success rate to obtain required data points to complete Fick principle calculations for all patients was 321/328 (98%). One patient with multiple shunts was an outlier and excluded from further analysis. The PCC for catheter-derived pulmonary blood flow (Qp) (0.89, p < 0.001) is slightly lower than iCMR-derived Qp (0.96, p < 0.001), whereas catheter-derived systemic blood flow (Qs) (0.62, p = < 0.001) was considerably lower than iCMR-derived Qs (0.94, p < 0.001). CCC agreement for Qp at baseline (C1-CCC = 0.65, 95% CI 0.41–0.81) and retested conditions (C2-CCC = 0.78, 95% CI 0.58–0.89) were better than for Qs at baseline (C1-CCC = 0.22, 95% CI − 0.15–0.53) and retested conditions (C2-CCC = 0.52, 95% CI 0.17–0.76). This study further validates hemodynamic measurements obtained via iCMR. iCMR-derived flows have considerably higher test–retest reliability for Qs. iCMR evaluations allow for more reproducible hemodynamic assessments in the CHD population.

21 June 2022 in Journal of Cardiac Surgery
Verified
Journal Article
Closed access
AHAbdelmonem Helal
Abdelmonem Helal
AEAhmed F. Elmahrouk
Ahmed F. Elmahrouk
SBSamia Bekheet
Samia Bekheet
HBHani I. Barnawi
Hani I. Barnawi
AJAhmed A. Jamjoom
Ahmed A. Jamjoom
RZRiad Abou Zahr
Riad Abou Zahr

1 August 2008 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Closed access
JBJames Alexander Browne
James Alexander Browne
APAlexander L. Pearson
Alexander L. Pearson
RZRiad Abou Zahr
Riad Abou Zahr
INIoana Niculescu-Duvaz
Ioana Niculescu-Duvaz
DBDeborah L Baines
Deborah L Baines
MDMark Dockrell
Mark Dockrell

29 September 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
RZRiad Abou Zahr
Riad Abou Zahr
BBBarbara Elisabeth Ursula Burkhardt
Barbara Elisabeth Ursula Burkhardt
LELubaina Ehsan
Lubaina Ehsan
APAmanda Potersnak
Amanda Potersnak
FGFranz Gerald Greil
Franz Gerald Greil
THTarique Hussain
Tarique Hussain
Background: Non-invasive determination of liver iron concentration (LIC) is a valuable tool that guides iron chelation therapy in transfusion-dependent patients. Multiple methods have been utilized to measure LIC by MRI. The purpose of this study was to compare free breathing R2* (1/T2*) to whole-liver Ferriscan R2 method for estimation of LIC in a pediatric and young adult population who predominantly have hemoglobinopathies. Methods: Clinical liver and cardiac MRI scans from April 2016 to May 2018 on a Phillips 1.5 T scanner were reviewed. Free breathing T2 and T2* weighted images were acquired on each patient. For T2, multi-slice spin echo sequences were obtained. For T2*, a single mid-liver slice fast gradient echo was performed starting at 0.6 ms with 1.2 ms increments with signal averaging. R2 measurements were performed by Ferriscan analysis. R2* measurements were performed by quantitative T2* map analysis. Results: 107 patients underwent liver scans with the following diagnoses: 76 sickle cell anemia, 20 Thalassemia, 9 malignancies and 2 Blackfan Diamond anemia. Mean age was 12.5 ± 4.5 years. Average scan time for R2 sequences was 10 min, while R2* sequence time was 20 s. R2* estimation of LIC correlated closely with R2 with a correlation coefficient of 0.94. Agreement was strongest for LIC < 15 mg Fe/g dry weight. Overall bias from Bland–Altman plot was 0.66 with a standard deviation of 2.8 and 95% limits of agreement −4.8 to 6.1. Conclusion: LIC estimation by R2* correlates well with R2-Ferriscan in the pediatric age group. Due to the very short scan time of R2*, it allows imaging without sedation or anesthesia. Cardiac involvement was uncommon in this cohort.