Anthea Raisis

Dr. Anthea Raisis

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2005 in Veterinary Anaesthesia and Analgesia
Verified
Journal Article
Closed access
PDF file
ARAnthea Raisis
Anthea Raisis

1 May 2007 in Veterinary Anaesthesia and Analgesia
Verified
Journal Article
Closed access
PDF file
ARAnthea Raisis
Anthea Raisis
ELElizabeth A Leece
Elizabeth A Leece
SPSimon R Platt
Simon R Platt
VAVicki Jean Adams
Vicki Jean Adams
FCFederico Corletto
Federico Corletto
JBJackie Brearley
Jackie Brearley

10 May 2021 in Animals
Verified
Journal Article
Open access
PDF file
BCBenedetta Crivellari
Benedetta Crivellari
ARAnthea Raisis
Anthea Raisis
GHGiselle Hosgood
Giselle Hosgood
AWAndreas D. Waldmann
Andreas D. Waldmann
DMDavid Murphy
David Murphy
MMMartina Mosing
Martina Mosing
This study explores the application of electric impedance tomography (EIT) to estimate tidal volume (VT) by measuring impedance change per breath (∆Zbreath). Seventeen healthy horses were anaesthetised and mechanically ventilated for elective procedures requiring dorsal recumbency. Spirometric VT (VTSPIRO) and ∆Zbreath were recorded periodically; up to six times throughout anaesthesia. Part 1 assessed these variables at incremental delivered VT of 10, 12 and 15 mL/kg. Part 2 estimated VT (VTEIT) in litres from ∆Zbreath at three additional measurement points using a line of best fit obtained from Part 1. During part 2, VT was adjusted to maintain end-tidal carbon dioxide between 45–55 mmHg. Linear regression determined the correlation between VTSPIRO and ∆Zbreath (part 1). Estimated VTEIT was assessed for agreement with measured VTSPIRO using Bland Altman analysis (part 2). Marked variability in slope and intercepts was observed across horses. Strong positive correlation between ∆Zbreath and VTSPIRO was found in each horse (R2 0.9–0.99). The agreement between VTEIT and VTSPIRO was good with bias (LOA) of 0.26 (−0.36–0.88) L. These results suggest that, in anaesthetised horses, EIT can be used to monitor and estimate VT after establishing the individual relationship between these variables.

1 March 2015 in Veterinary Anaesthesia and Analgesia
Verified
Journal Article
Closed access
PDF file
ARAnthea Raisis
Anthea Raisis
LSLisa Smart
Lisa Smart
EDEleanor Drynan
Eleanor Drynan
GHGiselle Hosgood
Giselle Hosgood

1 December 2017 in Research in Veterinary Science
Verified
Journal Article
Closed access
PTPhilomena P. Tuohy
Philomena P. Tuohy
ARAnthea Raisis
Anthea Raisis
EDEleanor A. Drynan
Eleanor A. Drynan

1 November 2005 in Veterinary Anaesthesia and Analgesia
Verified
Journal Article
Closed access
PDF file
ARAnthea Raisis
Anthea Raisis