The purpose of the research is to present a brief review of voltage source converter (VSC) topologies with their operating principles for energy applications, such as high voltage dc transmission (HVDC) and flexible ac transmission system (FACTS), which can be employed in the field of electric power generation, transmission and distribution systems. In this paper, several commonly used VSC-based high-power energy consumer topologies are presented and discussed, including the neutral-point-clamped (NPC), flying-capacitor (FC), cascaded H-bridge (CHB) and modular multilevel converters (MMC). A list of available industrial VSC-based high-power energy consumers is included. The most common and relevant energy applications of these converters are provided. At last, the directions of their future development are addressed. Each selection of converter topology and control method is closely related to each specific application, so that there are many options for different energy applications, depending on their own special technical specifications like system stability, dynamic performance, and total expenditure.
The existing publications on the analysis of power quality indicators in modern electric power supply systems are void of a comprehensive approach to improving these indicators in power systems by implementing multipulse connections. To the authors’ knowledge, this paper is the first to analyze current harmonic distortions in an 18-pulse connection of three-level active front-ends (AFE) featuring a programmed PWM. Raw data were obtained from, and current quality was analyzed for the power circuit of the main electric drive actuating the rolls in the rolling stand of a plate mill. The key feature of such circuitry is that the synchronous motor of each work roll is connected to the grid with an 18-pulse connection that uses three phase-shift transformers, where the phase shifts are 0° (delta/delta), 20° (delta/polygon) and −20° (delta/polygon). The circuitry connects three frequency converters (FC) with the AFEs in parallel. Phase-shift transformers were found to periodically overheat in the process. When overheating occurred, a programmed PWM voltage waveform was applied where harmonics 17 and 19 were eliminated. The goal and objectives were to analyze why the transformer would overheat and to find out how the issue could be addressed. The authors developed a simulation model of the research object in order to assess power quality parameters. Simulation results obtained in Matlab/Simulink were used to estimate the total harmonic distortions (THD) and individual harmonic factors for up to the 50th secondary transformer winding and grid harmonic with four different programmed AFE PWM voltage waveforms. The results helped find the best such waveform to prevent phase-shift transformers from overheating; one with harmonics 5, 7, 17 and 19 eliminated. The experimental and mathematical modeling results in the paper were confirmed by positive effects after industrial implementation of the system. Research performed directly on the operating equipment has been classified by the company and is not publicly available. These results are highly versatile and could be used in similar research on other circuitries to ensure the electromagnetic compatibility of nonlinear power-consuming devices.
Considering the development of the hybrid wind and solar photovoltaic generation and smart grid, Active Front-End (AFE) converters for high-power applications are facing significant opportunities and challenges related to power quality and efficiency. The Pre-programmed Pulse-Width Modulation (PPWM) techniques can strictly control the harmonic spectrum of a specified voltage or current waveform generated by a high-power AFE converters, and have been extensively applied to reduce or even eliminate the harmonic distortion with low switching losses for high-power converters in order to deal with these issues aforementioned. For the PPWM techniques with low switching frequency, Selective Harmonic Elimination (SHE) and Selective Harmonic Mitigation (SHM) have been the prevailing solutions and gain widespread popularity, among which SHM can provide further control of the harmonic spectrum in cases of similar switching losses to SHE. Over the past several decades, the applications of SHE and SHM have been extended to high-power AFE converters. Thus, the aim of this study is to provide a comprehensive literature review regarding their various formulations, solving algorithms, and existing problems to high-power AFE converters. In addition, the suggestions for future applications of PPWM in high-power AFE converters are also discussed.
Harmonic elimination of multilevel inverters is a complicated optimization issue involving constrained nonlinear transcendental equations with multiple solutions. A method to the selective harmonic elimination (SHE) technique by applying a particle swarm optimization (PSO) based on varied inertia weight in the iterative procedure is presented in this paper, which can avoid falling into the local optimum and improve the algorithm robustness so as to acquire the global optimum of the solution space. The proposed scheme can quickly obtain diverse solutions of switching patterns, while it is hard to determine them through conventional approaches like iterative techniques and resultant theory. Here, considering the elimination of low-order harmonics, these switching angles are calculated offline by computer. Theoretical results are analyzed and verified by simulations for a three-level neutral point clamped (3L-NPC) inverter. Simulation results show that the above mentioned approach effectively eliminates the specified lower order harmonics, whereas the switching angle trajectory and total harmonic distortion (THD) of output voltage are different.
1 December 2019 in International Journal of Power Electronics and Drive Systems (IJPEDS)
This paper presents a hybrid pulse width modulation (HPWM) strategy based on different switching patterns of selective harmonic elimination pulse width modulation (SHEPWM) for the three-level neutral point clamped (3L-NPC) converter. Specific low-order harmonics can be eliminated by SHEPWM at low switching frequency, while the remaining high-order harmonics can be selected to be simply filtered by additional hardware. Large oscillation waveform usually occurs in the transition instant between two diverse modulation situations, therefore switching between distinct switching patterns can be problematic if no effective means is taken, especially when the effect of smooth and fast transition at any time is considerable. A universal and valid control strategy, which maintains the high-quality output voltage and current, is proposed and implemented in this paper to address this issue. Simulation results obtained from MATLAB/SIMULINK are presented to analyze the performance and validate the feasibility and effectiveness of this control scheme.
Preprogrammed pulse width modulation (PPWM) techniques are drawing a great deal of interest due to their strong harmonic performance. However, there have not yet been any systematic studies or elaboration of the influence of different grid powers on current and voltage THD using PPWM. Therefore, this article focuses on a comparative analysis of current and voltage THD in a system with a three-phase, three-level active front-end (AFE) at different grid powers by applying PPWM. A six-pulse electric drive power circuit and one laboratory measurement platform were designed and set up to achieve the above goals. The comparative results were calculated up to the 50th (THD50) and 100th (THD100) harmonics against the frequency of the PPWM, ranging between 150 Hz and 750 Hz. The grid power and AFE power ratio was between 30 and 230 under three different AFE-consumed currents. The experimental results were analyzed and compared, and they demonstrated for the first time how the grid power and AFE power ratio with different PPWM patterns can influence current and voltage THD. The research results suggest that it is necessary to review the existing calculation methods for current and voltage THD using modern electric power quality standards. The results presented in this article also provide a reference point for researchers and engineers when considering the electromagnetic compatibility (EMC) of nonlinear consumers in the design of similar circuits.