Andrew Feola

Dr. Andrew Feola


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2009 in European Journal of Obstetrics & Gynecology and Reproductive Biology
Verified
Journal Article
Closed access
SASteven Abramowitch
Steven Abramowitch
AFAndrew Feola
Andrew Feola
ZJZegbeh Jallah
Zegbeh Jallah
PMPamela A. Moalli
Pamela A. Moalli

14 December 2012 in BJOG: An International Journal of Obstetrics & Gynaecology
Verified
Journal Article
Open access
PDF file
RLR Liang
R Liang
SAS Abramowitch
S Abramowitch
KKK Knight
K Knight
SPS Palcsey
S Palcsey
ANA Nolfi
A Nolfi
PMPa Moalli
Pa Moalli
Objective: To compare the impact of the prototype prolapse mesh Gynemesh PS with that of two new‐generation lower stiffness meshes, UltraPro and SmartMesh, on vaginal morphology and structural composition.Design: A mechanistic study employing a nonhuman primate model.Setting: Magee‐Womens Research Institute at the University of Pittsburgh.Population: Parous rhesus macaques, with similar age, weight, parity and Pelvic Organ Prolapse‐Questionnaire scores.Methods: Following Institutional Animal Care Use Committee approval, 50 rhesus macaques were implanted with Gynemesh PS (n = 12), UltraPro with its blue line perpendicular to the longitudinal axis of vagina (n = 10), UltraPro with its blue line parallel to the longitudinal axis of vagina (n = 8) or SmartMesh (n = 8) via sacrocolpopexy following hysterectomy. Sham‐operated animals (n = 12) served as controls.Main outcome measures: The mesh–vagina complex was removed after 12 weeks and analysed for histomorphology, in situ cell apoptosis, total collagen, elastin, glycosaminoglycan content and total collagenase activity. Appropriate statistics and correlation analyses were performed accordingly.Results: Relative to sham and the two lower stiffness meshes, Gynemesh PS had the greatest negative impact on vaginal histomorphology and composition. Compared with sham, implantation with Gynemesh PS caused substantial thinning of the smooth muscle layer (1557 ± 499 μm versus 866 ± 210 μm, P = 0.02), increased apoptosis particularly in the area of the mesh fibres (P = 0.01), decreased collagen and elastin content (20%, P = 0.03 and 43%, P = 0.02, respectively) and increased total collagenase activity (135%, P = 0.01). Glycosaminoglycan, a marker of tissue injury, was highest with Gynemesh PS compared with sham and other meshes (P = 0.01).Conclusion: Mesh implantation with the stiffer mesh Gynemesh PS induced a maladaptive remodelling response consistent with vaginal degeneration.

14 December 2012 in BJOG: An International Journal of Obstetrics & Gynaecology
Verified
Journal Article
Open access
PDF file
AFAndrew Feola
Andrew Feola
SAS Abramowitch
S Abramowitch
ZJZ Jallah
Z Jallah
SSS Stein
S Stein
WBW Barone
W Barone
PMP Moalli
P Moalli
Objective: To define the impact of prolapse mesh on the biomechanical properties of the vagina by comparing the prototype Gynemesh PS (Ethicon) to two new‐generation lower stiffness meshes, SmartMesh (Coloplast) and UltraPro (Ethicon).Design: A study employing a nonhuman primate model.Setting: University of Pittsburgh, PA, USA.Population: Forty‐five parous rhesus macaques.Methods: Meshes were implanted via sacrocolpopexy after hysterectomy and compared with sham. Because its stiffness is highly directional, UltraPro was implanted in two directions: UltraPro Perpendicular (less stiff) and UltraPro Parallel (more stiff), with the indicated direction referring to the position of the blue orientation lines relative to the longitudinal axis of the vagina. The mesh–vaginal complex (MVC) was excised in toto after 3 months.Main outcome measures: Active mechanical properties were quantified as the contractile force generated in the presence of 120 mmol/l KCl. Passive mechanical properties (a tissue's ability to resist an applied force) were measured using a multiaxial protocol.Results: Vaginal contractility decreased by 80% following implantation with the Gynemesh PS (P = 0.001), 48% after SmartMesh (P = 0.001), 68% after UltraPro Parallel (P = 0.001) and was highly variable after UltraPro Perpendicular (P = 0.16). The tissue contribution to the passive mechanical behaviour of the MVC was drastically reduced for Gynemesh PS (P = 0.003), but not for SmartMesh (P = 0.9) or UltraPro independent of the direction of implantation (P = 0.68 and P = 0.66, respectively).Conclusions: Deterioration of the mechanical properties of the vagina was highest following implantation with the stiffest mesh, Gynemesh PS. Such a decrease associated with implantation of a device of increased stiffness is consistent with findings from other systems employing prostheses for support.

1 April 2016 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
AFAndrew Feola
Andrew Feola
JMJerry G. Myers
Jerry G. Myers
JRJulia Raykin
Julia Raykin
LMLealem Mulugeta
Lealem Mulugeta
ENEmily S. Nelson
Emily S. Nelson
CEC. Ross Ethier
C. Ross Ethier
Purpose: Visual impairment and intracranial pressure (VIIP) syndrome is a health concern for long-duration spaceflight, and a proposed risk factor is elevation of intracranial pressure (ICP). Our goal was to use finite element modeling to simulate how elevated ICP and interindividual differences affect tissue deformation within the optic nerve head (ONH). Methods: We considered three ICP conditions: the upright and supine position on earth and an elevated ICP assumed to occur in chronic microgravity. Within each condition we used Latin hypercube sampling to consider a range of pressures and ONH tissue mechanical properties, determining the influence of each input on the following outcome measures: peak strains in the prelaminar tissue, lamina cribrosa, and retrolaminar optic nerve. Elevated strains can alter cell phenotype and induce tissue remodeling. Results: Elevating ICP increased the strains in the retrolaminar optic nerve. Variations in IOP, ICP, and in optic nerve and lamina cribrosa stiffness had the strongest influence on strains within the ONH. We predicted that 5% to 47% of individuals in microgravity would experience peak strains in the retrolaminar optic nerve larger than expected on earth. Having a soft optic nerve or pia mater and elevated ICP were identified as risk factors for these “extreme” strains. Conclusions: Intracranial pressure and mechanical properties of the ONH influence the risk for experiencing extreme strains in the retrolaminar optic nerve. These extreme strains may activate mechanosensitive cells that induce tissue remodeling and are a risk factor for the development of VIIP. Future studies must also consider variations in ONH anatomy.

1 May 2016 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
BCBaptiste Coudrillier
Baptiste Coudrillier
ICIan C. Campbell
Ian C. Campbell
ARA. Thomas Read
A. Thomas Read
DGDiogo M. Geraldes
Diogo M. Geraldes
NVNghia T. Vo
Nghia T. Vo
CEC. Ross Ethier
C. Ross Ethier
Purpose: Scleral stiffening has been proposed as a treatment for glaucoma to protect the lamina cribrosa (LC) from excessive intraocular pressure–induced deformation. Here we experimentally evaluated the effects of moderate stiffening of the peripapillary sclera on the deformation of the LC. Methods: An annular sponge, saturated with 1.25% glutaraldehyde, was applied to the external surface of the peripapillary sclera for 5 minutes to stiffen the sclera. Tissue deformation was quantified in two groups of porcine eyes, using digital image correlation (DIC) or computed tomography imaging and digital volume correlation (DVC). In group A (n = 14), eyes were subjected to inflation testing before and after scleral stiffening. Digital image correlation was used to measure scleral deformation and quantify the magnitude of scleral stiffening. In group B (n = 5), the optic nerve head region was imaged using synchrotron radiation phase-contrast microcomputed tomography (PC μCT) at an isotropic spatial resolution of 3.2 μm. Digital volume correlation was used to compute the full-field three-dimensional deformation within the LC and evaluate the effects of peripapillary scleral cross-linking on LC biomechanics. Results: On average, scleral treatment with glutaraldehyde caused a 34 ± 14% stiffening of the peripapillary sclera measured at 17 mm Hg and a 47 ± 12% decrease in the maximum tensile strain in the LC measured at 15 mm Hg. The reduction in LC strains was not due to cross-linking of the LC. Conclusions: Peripapillary scleral stiffening is effective at reducing the magnitude of biomechanical strains within the LC. Its potential and future utilization in glaucoma axonal neuroprotection requires further investigation.

26 November 2011 in International Urogynecology Journal
Verified
Journal Article
Closed access
PDF file
JSJonathan P. Shepherd
Jonathan P. Shepherd
AFAndrew Feola
Andrew Feola
SASteven D. Abramowitch
Steven D. Abramowitch
PMPamela A. Moalli
Pamela A. Moalli