Darragh Murnane

Prof. Darragh Murnane

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2013 in International Journal of Pharmaceutics
Verified
Journal Article
Open access
SJSara Jaffari
Sara Jaffari
BFBen Forbes
Ben Forbes
ECElizabeth Collins
Elizabeth Collins
David BarlowDavid Barlow
David Barlow
GMGary P. Martin
Gary P. Martin
DMDarragh Murnane
Darragh Murnane
Understanding and controlling powder de-agglomeration is of great importance in the development of dry powder inhaler (DPI) products. Dry dispersion laser diffraction measures particle size readily under controlled dispersing conditions, but has not been exploited fully to characterise inherent powder dispersibility. The aim of the study was to utilise particle size-dispersing pressure titration curves to characterise powder cohesivity and ease of de-agglomeration. Seven inhaled drug/excipient powders (beclometasone dipropionate, budesonide, fluticasone propionate, lactohale 300, salbutamol base, salmeterol xinafoate and tofimilast) were subjected to a range of dispersing pressures (0.2-4.5 Bar) in the Sympatec HELOS/RODOS laser diffractometer and particle size measurements were recorded. Particle size-primary pressure data were used to determine the pressures required for complete de-agglomeration. The latter were employed as an index of the cohesive strength of the powder (critical primary pressure; CPP), and the curves were modelled empirically to derive the pressure required for 50% de-agglomeration (DA₅₀). The powders presented a range of CPP (1.0-3.5 Bar) and DA₅₀ (0.23-1.45 Bar) which appeared to be characteristic for different mechanisms of powder de-agglomeration. This approach has utility as a rapid pre-formulation tool to measure inherent powder dispersibility, in order to direct the development strategy of DPI products.

2 December 2014 in Analytical Chemistry
Verified
Journal Article
Closed access
SASheelan Ahmad
Sheelan Ahmad
MTMichael Tucker
Michael Tucker
NSNeil Spooner
Neil Spooner
DMDarragh Murnane
Darragh Murnane
UGUte Gerhard
Ute Gerhard

1 March 2014 in International Journal of Pharmaceutics
Verified
Journal Article
Open access
AHAllen Haddrell
Allen Haddrell
JDJames F. Davies
James F. Davies
RMRachael E.H. Miles
Rachael E.H. Miles
JRJonathan Reid
Jonathan Reid
LDLea Ann Dailey
Lea Ann Dailey
DMDarragh Murnane
Darragh Murnane
The size of aerosol particles prior to, and during, inhalation influences the site of deposition within the lung. As such, a detailed understanding of the hygroscopic growth of an aerosol during inhalation is necessary to accurately model the deposited dose. In the first part of this study, it is demonstrated that the aerosol produced by a nebulizer, depending on the airflows rates, may experience a (predictable) wide range of relative humidity prior to inhalation and undergo dramatic changes in both size and solute concentration. A series of sensitive single aerosol analysis techniques are then used to make measurements of the relative humidity dependent thermodynamic equilibrium properties of aerosol generated from four common nebulizer formulations. Measurements are also reported of the kinetics of mass transport during the evaporation or condensation of water from the aerosol. Combined, these measurements allow accurate prediction of the temporal response of the aerosol size prior to and during inhalation. Specifically, we compare aerosol composed of pure saline (150 mM sodium chloride solution in ultrapure water) with two commercially available nebulizer products containing relatively low compound doses: Breath®, consisting of a simple salbutamol sulfate solution (5 mg/2.5 mL; 1.7 mM) in saline, and Flixotide® Nebules, consisting of a more complex stabilized fluticasone propionate suspension (0.25 mg/mL; 0.5 mM in saline. A mimic of the commercial product Tobi© (60 mg/mL tobramycin and 2.25 mg/mL NaCl, pH 5.5-6.5) is also studied, which was prepared in house. In all cases, the presence of the pharmaceutical was shown to have a profound effect on the magnitude, and in some cases the rate, of the mass flux of water to and from the aerosol as compared to saline. These findings provide physical chemical evidence supporting observations from human inhalation studies, and suggest that using the growth dynamics of a pure saline aerosol in a lung inhalation model to represent nebulizer formulations may not be representative of the actual behavior of the aerosolized drug solutions.

24 November 2014 in Molecular Pharmaceutics
Verified
Journal Article
Open access
VRVasuki Ramachandran
Vasuki Ramachandran
DMDarragh Murnane
Darragh Murnane
Robert B. HammondRobert B. Hammond
Robert B. Hammond
JPJonathan Pickering
Jonathan Pickering
KRKevin J. Roberts
Kevin J. Roberts
KPKlimentina Pencheva
Klimentina Pencheva
The synthonic modeling approach provides a molecule-centered understanding of the surface properties of crystals. It has been applied extensively to understand crystallization processes. This study aimed to investigate the functional relevance of synthonic modeling to the formulation of inhalation powders by assessing cohesivity of three active pharmaceutical ingredients (APIs, fluticasone propionate (FP), budesonide (Bud), and salbutamol base (SB)) and the commonly used excipient, α-lactose monohydrate (LMH). It is found that FP (−11.5 kcal/mol) has a higher cohesive strength than Bud (−9.9 kcal/mol) or SB (−7.8 kcal/mol). The prediction correlated directly to cohesive strength measurements using laser diffraction, where the airflow pressure required for complete dispersion (CPP) was 3.5, 2.0, and 1.0 bar for FP, Bud, and SB, respectively. The highest cohesive strength was predicted for LMH (−15.9 kcal/mol), which did not correlate with the CPP value of 2.0 bar (i.e., ranking lower than FP). High FP–LMH adhesive forces (−11.7 kcal/mol) were predicted. However, aerosolization studies revealed that the FP–LMH blends consisted of agglomerated FP particles with a large median diameter (∼4–5 μm) that were not disrupted by LMH. Modeling of the crystal and surface chemistry of LMH identified high electrostatic and H-bond components of its cohesive energy due to the presence of water and hydroxyl groups in lactose, unlike the APIs. A direct comparison of the predicted and measured cohesive balance of LMH with APIs will require a more in-depth understanding of highly hydrogen-bonded systems with respect to the synthonic engineering modeling tool, as well as the influence of agglomerate structure on surface–surface contact geometry. Overall, this research has demonstrated the possible application and relevance of synthonic engineering tools for rapid pre-screening in drug formulation and design.

1 March 2006 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
DMDarragh Murnane
Darragh Murnane
GMG.P. Martin
G.P. Martin
CMC. Marriott
C. Marriott

5 February 2013 in Analytical Chemistry
Verified
Journal Article
Closed access
JBJamie Barras
Jamie Barras
DMDarragh Murnane
Darragh Murnane
KAKaspar Althoefer
Kaspar Althoefer
SASulaf Assi
Sulaf Assi
MRMichael D. Rowe
Michael D. Rowe
JSJohn A. S. Smith
John A. S. Smith