Jian Sun

Dr. Jian Sun


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2024 in Energy and Buildings
Verified
Journal Article
Closed access
Pengtao WangPengtao Wang
Pengtao Wang
SKSteve Kowalski
Steve Kowalski
ZGZhiming Gao
Zhiming Gao
JSJian Sun
Jian Sun
CYCheng-Min Yang
Cheng-Min Yang
KNKashif Nawaz
Kashif Nawaz

3 October 2024 in Scientific Data
Verified
Journal Article
Open access
PDF file
JSJian Sun
Jian Sun
ZGZhiming Gao
Zhiming Gao
DGDavid Grant
David Grant
KNKashif Nawaz
Kashif Nawaz
PWPengtao Wang
Pengtao Wang
SHShean Huff
Shean Huff
The Hewlett Packard Enterprise–Cray EX Frontier is the world’s first and fastest exascale supercomputer, hosted at the Oak Ridge Leadership Computing Facility in Tennessee, United States. Frontier is a significant electricity consumer, drawing 8–30 MW; this massive energy demand produces significant waste heat, requiring extensive cooling measures. Although harnessing this waste heat for campus heating is a sustainability goal at Oak Ridge National Laboratory (ORNL), the 30 °C–38 °C waste heat temperature poses compatibility issues with standard HVAC systems. Heat pump systems, prevalent in residential settings and some industries, can efficiently upgrade low-quality heat to usable energy for buildings. Thus, heat pump technology powered by renewable electricity offers an efficient, cost-effective solution for substantial waste heat recovery. However, a major challenge is the absence of benchmark data on high-performance computing (HPC) heat generation and waste heat profiles. This paper reports power demand and waste heat measurements from an ORNL HPC data centre, aiming to guide future research on optimizing waste heat recovery in large-scale data centres, especially those of HPC calibre.

2 March 2022 in Scientific Data
Verified
Journal Article
Open access
PDF file
JSJian Sun
Jian Sun
MZMingkan Zhang
Mingkan Zhang
AGAnthony Gehl
Anthony Gehl
BFBrian Fricke
Brian Fricke
KNKashif Nawaz
Kashif Nawaz
DBDavid Brisson
David Brisson
Most COVID-19 vaccines require temperature control for transportation and storage. Two types of vaccine have been developed by manufacturers (Pfizer and Moderna). Both vaccines are based on mRNA and lipid nanoparticles requiring low temperature storage. The Pfizer vaccine requires ultra-low temperature storage (−80 °C to −60 °C), while the Moderna vaccine requires −30 °C storage. However, the last stage of distribution is quite challenging, especially for rural or suburban areas, where local towns, pharmacy chains and hospitals may not have the infrastructure required to store the vaccine at the required temperature. In addition, there is limited data available to address ancillary challenges of the distribution framework for both transportation and storage stages, including safety concerns due to human exposure to large amounts of CO2 from dry-ice sublimation, issues due to the pressure increase caused by dry-ice sublimation, and the potential issue caused by non-uniform cryogenic temperatures. As such, there is a need for test dataset to assist the development of a quick, effective, secure, and safe solution to mitigate the challenges faced by vaccine distribution logistics.

1 September 2019
Verified
Report
Closed access
PDF file
BCBorui Cui
Borui Cui
JJJaewan Joe
Jaewan Joe
JMJeffrey Munk
Jeffrey Munk
JSJian Sun
Jian Sun
TKTeja Kuruganti
Teja Kuruganti
The U.S. Department of Energy's Office of Scientific and Technical Information

27 May 2021 in Scientific Data
Verified
Journal Article
Open access
PDF file
JSJian Sun
Jian Sun
PIPiljae Im
Piljae Im
YBYeonjin Bae
Yeonjin Bae
JMJeff Munk
Jeff Munk
TKTeja Kuruganti
Teja Kuruganti
BFBrian Fricke
Brian Fricke
HVAC and refrigeration system fault detection and diagnostics (FDD) has attracted extensive studies for decades; however, FDD of supermarket refrigeration systems has not gained significant attention. Supermarkets consume around 50 kWh/ft2 of electricity annually. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40%–60% of its total electricity usage and is equivalent to about 2%–3% of the total energy consumed by commercial buildings in the United States. Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Reducing refrigerant usage or using environmentally friendly alternatives can result in significant climate benefits. A challenge is the lack of publicly available data sets to benchmark the system performance and record the faulted performance. This paper identifies common faults of supermarket refrigeration systems and conducts an experimental study to collect the faulted performance data and analyze these faults. This work provides a foundation for future research on the development of FDD methods and field automated FDD implementation.

1 June 2021 in International Journal of Refrigeration
Verified
Journal Article
Closed access
JSJian Sun
Jian Sun
TKTeja Kuruganti
Teja Kuruganti
JMJeff Munk
Jeff Munk
JDJin Dong
Jin Dong
BCBorui Cui
Borui Cui