Hans Hobbelen

Dr. Hans Hobbelen

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2011 in Ageing Research Reviews
Verified
Journal Article
Closed access
NVN.M. de Vries
N.M. de Vries
JSJ.B. Staal
J.B. Staal
CRC.D. van Ravensberg
C.D. van Ravensberg
HHHans Hobbelen
Hans Hobbelen
MRM.G.M. Olde Rikkert
M.G.M. Olde Rikkert
RSRia Nijhuis-van der Sanden
Ria Nijhuis-van der Sanden

31 January 2017 in European Journal of Ageing
Verified
Journal Article
Closed access
SBSteven Bunt
Steven Bunt
NSN. Steverink
N. Steverink
JOJ. Olthof
J. Olthof
CSC. P. van der Schans
C. P. van der Schans
HHHans Hobbelen
Hans Hobbelen

12 July 2017 in Journal of Cachexia, Sarcopenia and Muscle
Verified
Journal Article
Open access
PDF file
WNWillemke Nijholt
Willemke Nijholt
ASAldo Scafoglieri
Aldo Scafoglieri
HJHarriët Jager‐Wittenaar
Harriët Jager‐Wittenaar
HHHans Hobbelen
Hans Hobbelen
CSCees P. van der Schans
Cees P. van der Schans
This review evaluates the reliability and validity of ultrasound to quantify muscles in older adults. The databases PubMed, Cochrane, and Cumulative Index to Nursing and Allied Health Literature were systematically searched for studies. In 17 studies, the reliability (n = 13) and validity (n = 8) of ultrasound to quantify muscles in community‐dwelling older adults (≥60 years) or a clinical population were evaluated. Four out of 13 reliability studies investigated both intra‐rater and inter‐rater reliability. Intraclass correlation coefficient (ICC) scores for reliability ranged from −0.26 to 1.00. The highest ICC scores were found for the vastus lateralis, rectus femoris, upper arm anterior, and the trunk (ICC = 0.72 to 1.000). All included validity studies found ICC scores ranging from 0.92 to 0.999. Two studies describing the validity of ultrasound to predict lean body mass showed good validity as compared with dual‐energy X‐ray absorptiometry (r2 = 0.92 to 0.96). This systematic review shows that ultrasound is a reliable and valid tool for the assessment of muscle size in older adults. More high‐quality research is required to confirm these findings in both clinical and healthy populations. Furthermore, ultrasound assessment of small muscles needs further evaluation. Ultrasound to predict lean body mass is feasible; however, future research is required to validate prediction equations in older adults with varying function and health.

1 January 2012 in Ageing Research Reviews
Verified
Journal Article
Closed access
NVN.M. de Vries
N.M. de Vries
CRC.D. van Ravensberg
C.D. van Ravensberg
HHHans Hobbelen
Hans Hobbelen
MRM.G.M. Olde Rikkert
M.G.M. Olde Rikkert
JSJ.B. Staal
J.B. Staal
RSRia Nijhuis-van der Sanden
Ria Nijhuis-van der Sanden

1 July 2015 in BMC Geriatrics
Verified
Journal Article
Open access
PDF file
RARenske Van Abbema
Renske Van Abbema
MGMathieu De Greef
Mathieu De Greef
CCCeline Crajé
Celine Crajé
WKWim Krijnen
Wim Krijnen
HHHans Hobbelen
Hans Hobbelen
CSCees Van Der Schans
Cees Van Der Schans
Improved preferred gait speed in older adults is associated with increased survival rates. There are inconsistent findings in clinical trials regarding effects of exercise on preferred gait speed, and heterogeneity in interventions in the current reviews and meta-analyses. Objective: to determine the meta-effects of different types or combinations of exercise interventions from randomized controlled trials on improvement in preferred gait speed. Data sources: A literature search was performed; the following databases were searched for studies from 1990 up to 9 December 2013: PubMed, EMBASE, EBSCO (AMED, CINAHL, ERIC, Medline, PsycInfo, and SocINDEX), and the Cochrane Library. Study eligibility criteria: Randomized controlled trials of exercise interventions for older adults ≥ 65 years, that provided quantitative data (mean/SD) on preferred gait speed at baseline and post-intervention, as a primary or secondary outcome measure in the published article were included. Studies were excluded when the PEDro score was ≤4, or if participants were selected for a specific neurological or neurodegenerative disease, Chronic Obstructive Pulmonary Disease, cardiovascular disease, recent lower limb fractures, lower limb joint replacements, or severe cognitive impairments. The meta-effect is presented in Forest plots with 95 % confidence Study appraisal and synthesis methods: intervals and random weights assigned to each trial. Homogeneity and risk of publication bias were assessed. Twenty-five studies were analysed in this meta-analysis. Data from six types or combinations of exercise interventions were pooled into sub-analyses. First, there is a significant positive meta-effect of resistance training progressed to 70-80 % of 1RM on preferred gait speed of 0.13 [CI 95 % 0.09-0.16] m/s. The difference between intervention- and control groups shows a substantial meaningful change (>0.1 m/s). Secondly, a significant positive meta-effect of interventions with a rhythmic component on preferred gait speed of 0.07 [CI 95 % 0.03-0.10] m/s was found. Thirdly, there is a small significant positive meta-effect of progressive resistance training, combined with balance-, and endurance training of 0.05 [CI 95 % 0.00-0.09] m/s. The other sub-analyses show non-significant small positive meta-affects. Progressive resistance training with high intensities, is the most effective exercise modality for improving preferred gait speed. Sufficient muscle strength seems an important condition for improving preferred gait speed. The addition of balance-, and/or endurance training does not contribute to the significant positive effects of progressive resistance training. A promising component is exercise with a rhythmic component. Keeping time to music or rhythm possibly trains higher cognitive functions that are important for gait. Limitations: The focus of the present meta-analysis was at avoiding as much heterogeneity in exercise interventions. However heterogeneity in the research populations could not be completely avoided, there are probably differences in health status within different studies.

1 October 2018 in Journal of Geriatric Physical Therapy
Verified
Journal Article
Closed access
PDF file
BDBieke Van Deun
Bieke Van Deun
HHHans Hobbelen
Hans Hobbelen
BCBarbara Cagnie
Barbara Cagnie
BEBirgit Van Eetvelde
Birgit Van Eetvelde
NNNele Van Den Noortgate
Nele Van Den Noortgate
DCDirk Cambier
Dirk Cambier
Background and purpose: The MyotonPRO is a portable device that measures muscle tone and biomechanical muscle properties objectively. MyotonPRO has already proven to be effective in measuring muscle properties in healthy and diseased populations. However, to the best of our knowledge, it has never been tested in individuals suffering from paratonia, a form of hypertonia frequently accompanying dementia. The aims of the present study were to (1) compare muscle tone, elasticity, and stiffness between 3 different subpopulations of young and old healthy adults and individuals with paratonia, and (2) investigate the intra- and interrater reproducibility of MyotonPRO measurements of the biceps brachii (BB) muscle in each subpopulation. Methods: MyotonPRO measurements of muscle tone, elasticity, and dynamic stiffness were carried out by 2 investigators on 2 different days over the BB muscles of 54 participants (18 healthy young adults, 20 healthy older adults, and 16 older individuals with paratonia). Muscle properties were compared between subpopulations using ANOVA/Welch and post hoc tests. Reliability (intraclass correlation coefficient) and agreement parameters (standard error of measurement and the minimal detectable change) were calculated. Results: Statistically significant differences between subpopulations were found in all parameters, except for stiffness between healthy elderly and individuals with paratonia. In the healthy subpopulations, (a) intrarater reliability was very high and intrarater agreement was good between 2 consecutive series, (b) between days intrarater reliability was low to high and intrarater agreement was variable, (c) interrater reliability was high to very high and interrater agreement was good. In individuals with paratonia, (a) intrarater reliability was moderate to high and agreement was variable between series, (b) between days intrarater reliability was poor to moderate and agreement was poor, (c) interrater reliability ranged from low to high with poor agreement. Conclusions: MyotonPRO measurements of the BB muscle showed good reproducibility in both healthy subpopulations, particularly for measurements performed within the same day. In individuals with paratonia, reliability and agreement were substantially lower. MyotonPRO can be used in clinical assessment and research. However, in individuals with paratonia, careful interpretation of results is required. Research in a larger sample of persons with paratonia at different stages of disease severity is recommended.