Fung-Rong Hu

Fung-Rong Hu


Research Focus & Metrics

Academic Career Length

42Years (1985-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
WKWei-Boon Khor
Wei-Boon Khor
VPVenkatesh N. Prajna
Venkatesh N. Prajna
PGPrashant Garg
Prashant Garg
JMJodhbir S. Mehta
Jodhbir S. Mehta
LXLixin Xie
Lixin Xie
DTDonald Tiang-Hwee Tan
Donald Tiang-Hwee Tan

1 August 2001 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
SCShu-Wen Chang
Shu-Wen Chang
ITI-Lun Tsai
I-Lun Tsai
FHFung-Rong Hu
Fung-Rong Hu
LLLuke Long-Kuang Lin
Luke Long-Kuang Lin
YSYung-Feng Shih
Yung-Feng Shih
AIMS To further understand the effect of refractive error on the corneal dimensions and function. METHODS Corneal curvature, corneal thickness, and axial length measurements were performed, as well as specular microscopy and fluorophotometry, on patients with various refractive statuses. 216 subjects, mean age 22.2 (SD 4.2) years, were examined. Patients with previous contact lens wear history, external eye diseases, as well as previous ocular surgeries, were excluded. RESULTS The corneas were flatter in eyes with longer axial length (r = −0.22, p = 0.003). Eyes with more myopic spherical equivalent had longer axial length (r = −0.90, p <0.001) as well as less corneal endothelial density (r = 0.20, p = 0.037). Corneal endothelial density decreased in eyes with longer axial length (r = 0.24, p = 0.019); however, it correlated neither with corneal thickness (r= −0.06, p = 0.59) nor with corneal curvature (r = −0.07, p = 0.52). The corneas had a mean corneal thickness of 533 (SD 29) μm and were thinner in more myopic eyes (r = 0.16, p = 0.021). The corneas tended to be thinner in eyes with longer axial length. However, the correlation did not reach statistical significance (r = −0.11, p = 0.14). Besides, there was no significant correlation between the corneal thickness and the corneal curvature (r = −0.13, p = 0.093) and the endothelial permeability (r = 0.042, p = 0.69). The corneas with higher endothelial density had larger corneal transfer coefficient (r = 0.26, p = 0.024) and higher permeability to fluorescein molecules (r = 0.28, p = 0.014). Nevertheless, the corneal endothelial permeability did not correlate significantly with either the axial length (r = −0.18, p = 0.11) or the degree of myopia (r = 0.12, p = 0.26). CONCLUSION Changes in the anterior segments as the eyeball elongates in myopia progression included flatter corneal curvature, decreased corneal thickness, as well as decreased endothelial density. These factors should be considered in refractive surgery.

1 February 2004 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
CFChien-Fan Fong
Chien-Fan Fong
CTChia-Hui Tseng
Chia-Hui Tseng
FHFung-Rong Hu
Fung-Rong Hu
IWI-Jong Wang
I-Jong Wang
WCWei-Li Chen
Wei-Li Chen
YHYu-Chih Hou
Yu-Chih Hou

1 November 2014 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
CSChien-Chia Su
Chien-Chia Su
FHFung-Rong Hu
Fung-Rong Hu
TWTsing-Hong Wang
Tsing-Hong Wang
JHJehn-Yu Huang
Jehn-Yu Huang
PYPo-Ting Yeh
Po-Ting Yeh
IWI-Jong Wang
I-Jong Wang

1 September 2006 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
PCPei-Yao Chang
Pei-Yao Chang
HCHyman Carrel
Hyman Carrel
JHJen-Shang Huang
Jen-Shang Huang
IWI-Jong Wang
I-Jong Wang
YHYu-Chih Hou
Yu-Chih Hou
FHFung-Rong Hu
Fung-Rong Hu

1 April 2003 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
YLYuan-Chieh Lee
Yuan-Chieh Lee
FHFung-Rong Hu
Fung-Rong Hu
IWI-Jong Wang
I-Jong Wang
To determine the influence of pupil size and the amount of ablation on visual performance and on the patient's perception of glare or halo after laser in situ keratomileusis (LASIK). Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan. This study included a random cross-section of 50 eyes of 32 patients with "uniform" topography at least 6 months after LASIK and 51 eyes of 28 patients who had normal corneas. Each LASIK patient completed a survey rating adverse effects such as symptoms of night glare and halo. Pupil diameter and best spectacle-corrected visual acuity (BSCVA) were measured under photopic and scotopic conditions. Contrast sensitivity was measured with an MCT 8000 (Vistech Consultants, Inc.) under daytime and nighttime and with night glare conditions. A Technomed C-scan (Technomed Technology) was performed, and the potential corneal visual acuity (PCVA) was calculated after the settings for the pupil size were changed to the values measured under bright-light or dim-light conditions. No significant difference was found between the post-LASIK and normal cornea groups in photopic or scotopic BSCVA (P>.05). In cases of moderate myopia, the post-LASIK group had decreased PCVA and contrast sensitivity (P<.05). In cases of high myopia, the post-LASIK group had decreased contrast sensitivity at spatial frequencies of 1.5 cycles per degree (cpd) under daytime conditions and 3 cpd under nighttime conditions (P<.05). Glare or halo symptoms did not correlate with scotopic BSCVA, PCVA, or nighttime contrast sensitivity with or without glare (P>.05). Pupil size was not significantly correlated with glare or halo symptoms, BSCVA, or contrast sensitivity under scotopic or photopic conditions (P>.05). In moderate myopia, the amount of attempted correction of the spherical equivalent (SE) was correlated with halo symptoms (P<.05; adjusted r(2) = 0.17). In high myopia, the amount of attempted astigmatism correction was correlated with the development of glare symptoms (P<.05; adjusted r(2) = 0.16). There was a decrease in contrast sensitivity in post-LASIK eyes. The amount of attempted correction of the SE or astigmatism was correlated with the development of glare and halo symptoms. Pupil size was not significantly correlated with glare or halo symptoms, BSCVA, or contrast sensitivity in post-LASIK patients with "uniform" topography who had scotopic pupils not larger than 7.0 mm.