(1) Background: The ECETOC Targeted Risk Assessment (TRA) tool is widely used for estimation of worker exposure levels in the development of dossiers for REACH registration of manufactured or imported chemical substances in Europe. A number of studies have been published since 2010 in which the exposure estimates of the tool are compared with workplace exposure measurement results and in some instances an underestimation of exposure was reported. The quality and results of these studies are being reviewed by ECETOC. (2) Methods: Original exposure measurement data from published comparison studies for which six or more data points were available for each workplace scenario and a TRA estimate had been developed to create a curated database to examine under what conditions and for which applications the tool is valid or may need adaptation. (3) Results: The published studies have been reviewed for completeness and clarity and TRA estimates have been constructed based on the available information, following a set of rules. The full review findings are expected to be available in the course of 2021. (4) Conclusions: The ECETOC TRA tool developers periodically review the validity and limitations of their tool, in line with international recommendations.
4 March 2014 in Environmental Science: Processes & Impacts
In this study, 129 exposure situations (ESs) with six or more measured inhalation exposures to dust from solids or vapour from liquids in occupational settings were compared with modelled European Centre of Ecotoxicology and Toxicology of Chemicals (ECETOC) targeted risk assessment tool, version 3 (TRAv3) estimates. The measurement data were extracted from previously published studies examining TRAv3 performance and pooled into a curated database. The comparison exercise focussed on the vapour exposure scenarios, as there were too few dust scenarios for a meaningful analysis of any required model corrections. A group of experts in the exposure modelling field retrieved and reviewed the input parameters used in these ESs. Where considered appropriate, modifications were applied to better match the input parameter definitions and the scope of applicability of the TRAv3. Differences and mean absolute error (MAE) were calculated between the log-transformed modelled exposure value and the 75th percentile of each measured data set and regression analysis was performed. The results indicated that the TRAv3 overestimated 80% of the measured data sets. Both over- and underestimations were mostly by factors 1–5. The calculated MAE for liquids was 0.7, indicating that on average the difference between the 75th percentile and the TRAv3 estimate was less than one order of magnitude. A multiple linear regression showed that some input parameters such as medium volatility, certain process categories (PROC), industrial setting, and the presence of local exhaust ventilation are associated with underestimations. The results of the regression analysis can be used by TRAv3 users to review the degree of over- or underestimation in their current exposure assessments, compared to the curated database. Although multiple linear regression is an appropriate methodology to characterize the TRAv3’s performance, more data sets are still needed in view of some remaining data gaps. Nevertheless, the results of the current analysis are being used by ECETOC to further develop the tool as a suitably conservative screening tool for use in REACH chemical safety assessment of occupational exposure to chemicals.
1 November 2023 in Journal of Occupational and Environmental Hygiene
In response to increasing focus on occupational exposures to welding fume, a 10-year series of personal exposure measurements was analyzed for the two main welding processes (Shielded Metal Arc Welding or Stick and Tungsten Inert Gas welding or TIG) used in an oil refinery setting. Exposures from ancillary gouging and grinding were also analyzed. The operations were conducted under a permit-to-work system, which stipulated control measures in the form of ventilation and respiratory protective equipment (RPE) depending on the work environment, base metal, and welding process. The analysis focused on three health hazards of interest: total particulate (TP); hexavalent chromium (Cr (VI)); and manganese (Mn). The study's aims were the analysis of exposure levels related to operational conditions to verify the adequacy of required control measures and the generation of quantitative information for the development of predictive exposure models. Arithmetic mean exposures were 2.01 mg/m(3) for TP (n = 94), 13.86 mu g/m(3) for Cr (VI) (n = 160), and 0.024 mg/m(3) for Mn (n = 95). Requirements and practices for ventilation and use of RPE appeared adequate for maintaining exposure levels below maximum use concentrations. Predictive models for mean exposure levels were developed using multiple linear regression. Different patterns emerged for TP, Cr (VI), and Mn exposure determinants. Enclosed or confined work environments were associated with elevated exposure levels, regardless of the provision of local exhaust or general dilution ventilation. Carbon arc, used with gouging and grinding, contributed significantly to TP exposure (p = 0.006). The relative TP source strengths of the two main welding processes were comparable to the literature data. For Cr (VI), stick welding was associated with approximately 50-fold (p < 0.001) higher exposure potential than TIG welding. For Mn, this difference was approximately 2.5-fold. Differences were observed across the three analytes in exposure reduction efficiency of local exhaust ventilation (LEV) compared to natural ventilation, possibly due to ineffective use in confined spaces. These findings contribute to the overall understanding of TP, Cr (VI), and Mn exposures from welding and required controls in an oil refinery setting.