The increased integration of cyber and communication networks in microgrids for obtaining measurements and relaying controls results in a Cyber-Physical Microgrid (CPM) that paves the way for many essential applications. One of these applications is the Load Frequency Control (LFC), which is more challenging due to the stochastic behavior of renewable generation. The CPM also facilitates the participation of Electric Vehicle (EV) batteries in LFC. These information and communication technologies provide a myriad of advantages but also lead to a close synergy between heterogeneous physical and cyber components unlocking access points for cyber intrusions. A cyber intrusion camouflages and may present itself as uncertainty, eventually leading to astray controls and remedial actions. This leads to a need for an observer-based control strategy that can observe stochastic dynamic encumbrances and remunerate for them through a two-layer controller. The proposed controller is also investigated for its efficacy through Hardware-In-the-Loop (HIL) simulations in OPAL-RT that integrates the fidelity of physical simulations with the flexibility of numerical simulations.
Most power systems’ approaches are currently tending towards stochastic and probabilistic methods due to the high variability of renewable sources and the stochastic nature of loads. Conventional power flow (PF) approaches such as forward-backward sweep (FBS) and Newton-Raphson require a high number of iterations to solve non-linear PF equations making them computationally very intensive. PF is the most important study performed by utility, required in all stages of the power system, especially in operations and planning. This paper discusses the applications of deep learning (DL) to predict PF solutions for three-phase unbalanced power distribution grids. Three deep neural networks (DNNs); Radial Basis Function Network (RBFnet), Multi-Layer Perceptron (MLP), and Convolutional Neural Network (CNN), are proposed in this paper to predict PF solutions. The strength of the proposed DNN models over the traditional iterative-based PF solvers is that these models can capture the nonlinear relationships in PF calculations to accurately predict the solutions. The PF problem is formulated as a multi-output regression model where two or more output values are predicted based on the inputs. The training and testing data are generated through the OpenDSS-MATLAB COM interface. These methods are completely data-driven where the training relies on reducing the mismatch at each node without the need for the knowledge of the system. The novelty of the proposed methodology is that the models can accurately predict the PF solutions for the unbalanced distribution grids with mutual coupling and are robust to different R/X ratios, topology changes as well as generation and load variability introduced by the integration of distributed energy resources (DERs) and electric vehicles (EVs). To test the efficacy of the DNN models, they are applied to IEEE 4-node and 123-node test cases, and the American Electric Power (AEP) feeder model. The PF results for RBFnet, MLP, and CNN models are discussed in this paper which demonstrate that all three DNN models provide highly accurate results in predicting PF solutions.
Low‐frequency oscillations in power system degrade power quality and may trigger blackouts. This study identifies the source location of these oscillations using measurements from phasor measurement unit (PMU), offline credibility estimation and classification models. The performance of these classification models is ranked for each reported feature to use highly ranked models during the online stage. This proposed framework named as credibility search ensemble learning was tested and validated with promising results using western interconnection power system in North America (WECC‐179). The reliability and robustness of the proposed framework were checked against measurement errors in PMUs as well as for practical topology change scenarios. Experimental results and performance comparison with average weight‐based approach proved that the proposed approach is capable enough to predict the source location of oscillations with good accuracy. An interfacing tool, for MATLAB‐WEKA, was developed and employed in this work for validation and testing of the proposed approach.
As the penetration of renewable energy, generally, uncertainties, increase in microgrids, a more dynamic and complex system is emerging that makes the load frequency control (LFC) of islanded microgrids more challenging due to their stochastic dynamic nature. This stochastic nature can create oscillatory frequency response, which eventually leads to deteriorating control function and instability even under primary and traditional secondary controllers. Due to the uncertainties, the measurements and microgrid states are continually perturbed; hence, they cannot be directly utilized for feedback control. Therefore, it is required to utilize an observer-based stochastic feedback control that correctly recognizes these uncertainties and sieves incorrect states, frequency deviation here, and can properly maintain the balance between the energy sources and the demand. This article develops an optimal observer-based secondary control for LFC, framed in two layers that are the stochastic unknown input observer (SUIO) and linear quadratic regulator. The proposed SUIO not only can address the uncertainties, e.g., renewable energy, load, and measurement noise, with efficient control effort but also performs robust against parameter changes of the microgrid. The simulation results confirm the efficacy of this proposed control as compared to the traditional secondary control method.
Inverter-based energy resource is a fast emerging technology for microgrids. Operation of micorgrids with integration of these resources, especially in an islanded operation mode, is challenging. To effectively capture microgrid dynamics and also control these resources in islanded microgrids, a heavy cyber and communication infrastructure is required. This high reliance of microgrids on cyber interfaces makes these systems prone to cyber-disruptions. Hence, the hierarchical control of microgrids, including primary, secondary, and tertiary control, needs to be developed to operate resiliently. This paper shows the vulnerability of microgrid control in the presence of False Data Injection (FDI) attack, which is one type of cyber-disruption. Then, this paper focuses on designing a resilient secondary control based on Unknown Input Observer (UIO) against FDI. The simulation results show the superior performance of the proposed controller over other standard controllers.
18 August 2021 in IEEE Transactions on Industrial Informatics
This article presents a novel real-time attack monitoring framework to locate various attacks and identify postattack operating conditions (OCs) using enormous data measured by phasor measurement units (PMU's). Data Mining based online divisive-agglomerative time-series data stream clustering along with data reduction and classification techniques are employed to detect attacks and determine their location by monitoring a minimal number of measuring units. Attack severity and criticality indices are formulated to assess the severity of the attack and identify postattack critical elements in the system to prevent the attack resulting in a large failure. The proposed methodology is tested on IEEE 24 Bus reliability test system and 118 Bus test systems using simulated data considering attacks on different system elements under varying OCs. Additionally, the robustness and real-time applicability of the proposed attack detection methodology is verified, and its strengths and limitations are discussed.