We propose a model to determine the influence of different cell properties, such as size, membrane capacitance and cytoplasm conductivity, on the impedance spectrum as measured in a microfabricated cytometer. A dielectric sphere of equivalent complex permittivity is used as a simplified model to describe a biological cell. The measurement takes place between a pair of facing microelectrodes in a microchannel filled with a saline solution. The model incorporates various cell parameters, such as dielectric properties, size and position in the channel. A 3D finite element model is used to evaluate the magnitude of the electric field in the channel and the resultant changes in charge densities at the measurement electrode boundaries as a cell flows past. The charge density is integrated on the electrode surface to determine the displacement current and the channel impedance for the computed frequency range. The complete impedance model combines the finite element model, the electrode–electrolyte interface impedance and stray impedance, which are measured from a real device. The modeled dielectric complex spectra for various cell parameters are discussed and a measurement strategy for cell discrimination with such a system is proposed. We finally discuss the amount of noise and measurement fluctuations of the sensor.
: Purpose: Assessment on enucleated pig eyes of a novel and minimally invasive method for the continuous monitoring of intraocular pressure (IOP), based on a novel wireless contact lens sensor (CLS).Methods: The wireless CLS is a disposable silicone soft contact lens with a sensor embedded in it, allowing the wireless measurement of changes in corneal curvature induced by IOP variations. A CLS was adapted and tested on enucleated pig eyes. To demonstrate the measurement principle of the device, the enucleated pig eye was cannulated, allowing precise control of IOP. The CLS signal was then compared to the imposed IOP.Results: First, the IOP of enucleated pig eyes was changed between 11 and 14 mmHg, simulating ocular pulsation. Then, IOP was changed with static steps of 1 mmHg between 20 and 30 mmHg to assess the reproducibility and linearity of the CLS. In both cases, measurements from the CLS and IOP showed very good correlation. A calibration graph shows that the CLS is capable of monitoring the IOP of each individual eye with a reproducibility of ± 0.2 mmHg (95% confidence interval).Conclusion: The wireless CLS shows a good functionality to monitor the IOP on enucleated pig eyes. The device is placed in the same way as a soft disposable contact lens. This device would allow a minimally invasive and continuous monitoring of IOP over prolonged periods of up to 24 hr, regardless of patient activity, thus opening up new diagnostic and therapeutic methods to manage glaucoma.
1 September 2004 in Investigative Ophthalmology & Visual Science
Mixing liquids at the micro-scale is difficult because the low Reynolds numbers in microchannels and in microreactors prohibit the use of conventional mixing techniques based on mechanical actuators and induce turbulence. Static mixers can be used to solve this mixing problem. This paper presents micromixers with geometries very close to conventional large-scale static mixers used in the chemical and food-processing industry. Two kinds of geometries have been studied. The first type is composed of a series of stationary rigid elements that form intersecting channels to split, rearrange and combine component streams. The second type is composed of a series of short helix elements arranged in pairs, each pair comprised of a right-handed and left-handed element arranged alternately in a pipe. Micromixers of both types have been designed by CAD and manufactured with the integral microstereolithography process, a new microfabrication technique that allows the manufacturing of complex three-dimensional objects in polymers. The realized mixers have been tested experimentally. Numerical simulations of these micromixers using the computational fluid dynamics (CFD) program FLUENT™ are used to evaluate the mixing efficiency. With a low pressure drop and good mixing efficiency these truly three-dimensional micromixers can be used for mixing of reactants or liquids containing cells in many μTAS applications.