Studying human health in areas with industrial contamination is a serious and complex issue. In recent years, attention has increasingly focused on the health implications of large industrial complexes. A variety of potential toxic chemicals have been produced during manufacturing processes and activities in industrial complexes in South Korea. A large number of dyeing industries gathered together in Daegu dyeing industrial complex. The residents near the industrial complex could be often exposed to volatile organic compounds. This study aimed to evaluate VOCs levels in the ambient air of DDIC, to assess the impact on human health risks, and to find more convincing evidences to prove these VOCs emitted from DDIC. According to deterministic risk assessment, inhalation was the most important route. Residential indoor, outdoor and personal exposure air VOCs were measured by passive samplers in exposed area and controlled area in different seasons. Satisfaction with ambient environments and self-reported diseases were also obtained by questionnaire survey. The VOCs concentrations in exposed area and controlled area was compared by t-test. The relationships among every VOC were tested by correlation. The values of hazard quotient (HQ) and life cancer risk were estimated. The concentrations of measured VOCs were presented, moreover, the variety of concentrations according the distances from the residential settings to the industrial complex site in exposed area. The residential indoor, outdoor, and personal exposure concentrations of toluene, DMF and chloroform in exposed area were significantly higher than the corresponding concentrations in controlled area both in summer and autumn. Toluene, DMF, chloroform and MEK had significantly positive correlations with each other in indoor and outdoor, and even in personal exposure. The HQ for DMF exceeded 1, and the life cancer risk of chloroform was greater than 10− 4 in exposed area. The prevalence of respiratory diseases, anaphylactic diseases and cardiovascular diseases in exposed area were significantly higher than in controlled area. This study showed that adverse cancer and non-cancer health effects may occur by VOCs emitted from DDIC, and some risk managements are needed. Moreover, this study provides a convenient preliminarily method for pollutants source characteristics.
1 January 2016 in Journal of Korean Medical Science
This study aimed to measure lead (Pb) and cadmium (Cd) exposure levels in residents living near a zinc (Zn) smelter in Seokpo-myeon, Bonghwa-gun, South Korea, and identify factors affecting exposure. Residents aged ≥20 years living within 3 km and ≥30 km away from the smelter were classified as the exposure group (n = 549), and the control group (n = 265), respectively. Data were obtained through a questionnaire survey. Blood Pb levels in the exposure group (4.19 µg/dL) were higher than in the control group (2.70 µg/dL). The exposure group (1.32 µg/L) also had higher urinary Cd concentrations than the control group (0.80 µg/L). Male sex, older age, previous work at the smelter, smoking, and proximity to the smelter were associated with higher blood Pb levels on multivariate analysis; urinary Cd concentration was significantly higher in women, those who were older, those with experience of working in a Zn smelter or mine, those with proximity to the Zn smelter, and those who consumed locally grown vegetables. In conclusion, Zn smelters are major source of Pb and Cd pollution and require ongoing public health management to prevent potential adverse health effects.
Spatial interpolation is employed to improve exposure estimates and to assess adverse health effects associated with environmental risk factors. Since various studies have reported that high ozone (O3) concentrations can give rise to adverse effects on respiratory symptoms and lung function, we investigated the association between O3 levels and lung function using a variety of spatial interpolation techniques and evaluated how different methods for estimating exposure may influence health results for a cohort from an industrial complex (Gwangyang Bay) in South Korea in 2009. To estimate daily concentrations of O3 in each subject, four different methods were used, which include simple averaging, nearest neighbor, inverse distance weighting, and kriging. Also, to compare the association between O3 levels and lung function by age-groups, we explored ozone’s impacts on three age-related groups: children (9–14 years), adults (15–64 years), and the elderly (≥65 years). The overall change of effect size on lung function in each age group tended to show similar patterns for lag and methods for estimating exposure. A significant negative association was only observed between O3 levels and FVC and FEV1 for most of the lag and methods in children. The largest effect of O3 levels was found at the average for the lung function test day and last 2 days (0–2 days). In conclusions, the spatial interpolation methods may benefit in providing individual-level exposure with appropriate temporal resolution from ambient monitors. However, time-activity patterns of residents, monitoring site locations, methodological choices, and other factors should be considered to minimize exposure misclassification.
Nanomaterials are known to aggregate in the presence of ions. Similarly, the aggregation of zinc oxide nanoparticles (ZnO NPs) exposed to various ions such as sodium chloride and calcium chloride in water systems increases with the ionic strength. Therefore, for accurate toxicity studies, it is necessary to conduct a test using natural organic matters (NOMs) as additional dispersants that strengthen stability with increased repulsive forces. The three types of ecotoxicity tests based on the dispersion stability test using NOM showed that the toxicities of the three test samples decreased in the presence of NOM. To determine how NOM improved dispersion and reduced toxicities, we analyzed the ionization degree of ZnO NPs with and without NOM and found that the solubility was below 2 mg/L with a negligible change over time, implying that the ionization effect was low. The absolute value of the surface charge of particles increased in the presence of NOM, resulting in increased repulsive electrostatic forces and steric hindrance, causing less aggregation and more dispersion. Additionally, although the NOM used in the test is considered an effective dispersant that does not have a toxicological effect on aquatic organisms, the presence of NOM resulted in reduced toxicities and should be further investigated to establish it as a standard test method.