Electrochemical anodisation techniques are regularly used to modify carbon fiber surfaces as a means of improving electrochemical performance. A detailed study of the effects of oxidation (+ 2 V) in alkaline media has been conducted and Raman, XPS and SEM analyses of the modification process have been tallied with the resulting electrochemical properties. The co-application of ultrasound during the oxidative process has also been investigated to determine if the cavitational and mass transport features influence both the physical and chemical nature of the resulting fibers. Marked discrepancies between anodisation with and without ultrasound is evident in the C1s spectra with variations in the relative proportions of the electrogenerated carbon-oxygen functionalities. Mechanisms that could account for the variation in surface species are considered. Graphic
Catheter related blood stream infection is an ever present hazard for those patients requiring venous access and particularly for those requiring long term medication. The implementation of more rigorous care bundles and greater adherence to aseptic techniques have yielded substantial reductions in infection rates but the latter is still far from acceptable and continues to place a heavy burden on patients and healthcare providers. While advances in engineering design and the arrival of functional materials hold considerable promise for the development of a new generation of catheters, many challenges remain. The aim of this review is to identify the issues that presently impact catheter performance and provide a critical evaluation of the design considerations that are emerging in the pursuit of these new catheter systems.
A carbon-loaded polyethylene film was modified through a combination of laser ablation and electrochemical anodisation to yield a mechanically flexible yet electroanalytically sensitive mesh. A custom flavin derivative bearing a pendant phenol substituent was electropolymerised onto the substrate, and its electrochemical properties were investigated. The reversible flavin electrochemistry was retained (Ep = −0.374 V vs. Ag/AgCl, pH 7), and the peak position was found to shift by 60 mV/pH over a range covering pH 2.55 to pH 8.12. The stability of the resulting composite has been evaluated, and the analytical applicability towards the voltammetric measurement of pH in human urine was critically assessed.
The use of coliforms and Escherichia coli as indicator species for assessing the quality of water is well established and a large variety of methods based on β-galactosidase (B-GAL) activity, inherent to the microbes within this classification, have arisen to enable their detection and enumeration. Chlorophenol red (CPR) is widely used as a chromogenic label, but its capacity for translation to electroanalytical devices has yet to be fully explored. The CPR moiety is capable of undergoing oxidation at carbon substrates (+0.7 V) giving rise to a variety of phenolic intermediates. Electrochemical, XPS and enzymatic techniques were employed to characterise the underpinning chemistry and the intermediate identified as a 1,2-quinone derivative in which the chlorine substituent is retained. The latter was found to accumulate at the electrode and, in contrast to the parent CPR, was found to be detected at a significantly less positive potential (+0.3 V). Bacterial hydrolysis of a CPR labelled substrate was demonstrated with the 1,2-quinone oxidation product found to accumulate at the electrode and detected using square wave voltammetry. Proof of concept for the efficacy of the alternative electrode pathway was established through the detection of E.coli after an incubation time of 2.5 h with no interference from the labelled substrates.
Background: Catheter line infection is a common complication within clinical environments, and there is a pressing need for technological options to aid in reducing the possibility of sepsis. The early identification of contamination could be pivotal in reducing cases and improving outcomes. Method: A sensing rationale based on a riboflavin-modified electrode system integrated within a modified 3D-printed catheter needle-free connector is proposed, which can monitor changes in pH brought about by bacterial contamination. Results: Riboflavin, vitamin B2, is a biocompatible chemical that possesses a redox-active flavin core that is pH dependent. The oxidation peak potential of the adsorbed riboflavin responds linearly to changes in pH with a near-Nernstian behavior of 63 mV/pH unit and is capable of accurately monitoring the pH of an authentic IV infusate. Conclusions: The proof of principle is demonstrated with an electrode-printed hub design offering a valuable foundation from which to explore bacterial interactions within the catheter lumen with the potential of providing an early warning of contamination.