Jürgen Hartler

Prof. Jürgen Hartler

University of Graz
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2010 in Bioinformatics
Verified
Journal Article
Open access
PDF file
Jürgen HartlerJürgen Hartler
Jürgen Hartler
MTMartin Trötzmüller
Martin Trötzmüller
CCChandramohan Chitraju
Chandramohan Chitraju
FSFriedrich Spener
Friedrich Spener
Harald KöfelerHarald Köfeler
Harald Köfeler
GTGerhard G. Thallinger
Gerhard G. Thallinger
Motivation: The accurate measurement of the lipidome permits insights into physiological and pathological processes. Of the present high-throughput technologies, LC-MS especially bears potential of monitoring quantitative changes in hundreds of lipids simultaneously. In order to extract valuable information from huge amount of mass spectrometry data, the aid of automated, reliable, highly sensitive and specific analysis algorithms is indispensable. Results: We present here a novel approach for the quantitation of lipids in LC-MS data. The new algorithm obtains its analytical power by two major innovations: (i) a 3D algorithm that confines the peak borders in m/z and time direction and (ii) the use of the theoretical isotopic distribution of an analyte as selection/exclusion criterion. The algorithm is integrated in the Lipid Data Analyzer (LDA) application which additionally provides standardization, a statistics module for results analysis, a batch mode for unattended analysis of several runs and a 3D viewer for the manual verification. The statistics module offers sample grouping, tests between sample groups and export functionalities, where the results are visualized by heat maps and bar charts. The presented algorithm has been applied to data from a controlled experiment and to biological data, containing analytes distributed over an intensity range of 106. Our approach shows improved sensitivity and an extremely high positive predictive value compared with existing methods. Consequently, the novel algorithm, integrated in a user-friendly application, is a valuable improvement in the high-throughput analysis of the lipidome. Implementation and availability: The Java application is freely available for non-commercial users at http://genome.tugraz.at/lda. Raw data associated with this manuscript may be downloaded from ProteomeCommons.org Tranche using the following hash: ZBh3nS5bXk6I/Vn32tB5Vh0qnMpVIW71HByFFQqM0RmdF4/4Hcn H3Wggh9kU2teYVOtM1JWwHIeMHqSS/bc2yYNFmyUAAAAAAACl DQ == Contact:Gerhard.Thallinger@tugraz.at Supplementary information: Supplementary data are available from Bioinformatics online.

1 October 2014 in Molecular & Cellular Proteomics
Verified
Journal Article
Open access
PDF file
JGJohannes Griss
Johannes Griss
AJAndrew R. Jones
Andrew R. Jones
TSTimo Sachsenberg
Timo Sachsenberg
MWMathias Walzer
Mathias Walzer
LGLaurent Gatto
Laurent Gatto
HHHenning Hermjakob
Henning Hermjakob
The HUPO Proteomics Standards Initiative has developed several standardized data formats to facilitate data sharing in mass spectrometry (MS)-based proteomics. These allow researchers to report their complete results in a unified way. However, at present, there is no format to describe the final qualitative and quantitative results for proteomics and metabolomics experiments in a simple tabular format. Many downstream analysis use cases are only concerned with the final results of an experiment and require an easily accessible format, compatible with tools such as Microsoft Excel or R. We developed the mzTab file format for MS-based proteomics and metabolomics results to meet this need. mzTab is intended as a lightweight supplement to the existing standard XML-based file formats (mzML, mzIdentML, mzQuantML), providing a comprehensive summary, similar in concept to the supplemental material of a scientific publication. mzTab files can contain protein, peptide, and small molecule identifications together with experimental metadata and basic quantitative information. The format is not intended to store the complete experimental evidence but provides mechanisms to report results at different levels of detail. These range from a simple summary of the final results to a representation of the results including the experimental design. This format is ideally suited to make MS-based proteomics and metabolomics results available to a wider biological community outside the field of MS. Several software tools for proteomics and metabolomics have already adapted the format as an output format. The comprehensive mzTab specification document and extensive additional documentation can be found online.

23 October 2017 in Nature Methods
Verified
Journal Article
Closed access
PDF file
Jürgen HartlerJürgen Hartler
Jürgen Hartler
ATAlexander Triebl
Alexander Triebl
AZAndreas Ziegl
Andreas Ziegl
MTMartin Trötzmüller
Martin Trötzmüller
GRGerald N. Rechberger
Gerald N. Rechberger
GTGerhard G. Thallinger
Gerhard G. Thallinger

1 December 2011 in Journal of Lipid Research
Verified
Journal Article
Open access
AFAlexander Fauland
Alexander Fauland
Harald KöfelerHarald Köfeler
Harald Köfeler
MTMartin Trötzmüller
Martin Trötzmüller
AKAstrid Knopf
Astrid Knopf
Jürgen HartlerJürgen Hartler
Jürgen Hartler
FSFriedrich Spener
Friedrich Spener
This work aims to combine chromatographic retention, high mass resolution and accuracy, MS/MS spectra, and a package for automated identification and quantitation of lipid species in one platform for lipidomic analysis. The instrumental setup elaborated comprises reversed-phase HPLC coupled to a Fourier transform ion cyclotron resonance mass spectrometer (LTQ-FT), and Lipid Data Analyzer (LDA) software. Data analysis for lipid species quantification in this platform is based on retention time, mass resolution of 200,000, and mass accuracy below 2 ppm. In addition, automatically generated MS/MS spectra provide structural information at molecular level. This LC/MS technology allows analyzing complex biological samples in a quantitative manner as shown here paradigmatically for murine lipid droplets having a huge surplus of triacylglycerol species. Chromatographic preseparation of the bulk lipid class alleviates the problem of ion suppression of lipid species from other classes. Extension of 1D to 2D chromatography is possible, yet time consuming. The platform affords unambiguous detection of lipid species as low as 0.1‰ within major lipid classes. Taken together, a novel lipidomic LC/MS platform based on chromatographic retention, high mass resolution and accuracy, MS/MS analysis, and quantitation software enables analysis of complex samples as demonstrated for lipid droplets.

21 November 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JPJosch K. Pauling
Josch K. Pauling
MHMartin Hermansson
Martin Hermansson
Jürgen HartlerJürgen Hartler
Jürgen Hartler
KCKlaus Christiansen
Klaus Christiansen
SGSandra Fernandez Gallego
Sandra Fernandez Gallego
CEChrister S. Ejsing
Christer S. Ejsing
Advances in mass spectrometry-based lipidomics have in recent years prompted efforts to standardize the annotation of the vast number of lipid molecules that can be detected in biological systems. These efforts have focused on cataloguing, naming and drawing chemical structures of intact lipid molecules, but have provided no guidelines for annotation of lipid fragment ions detected using tandem and multi-stage mass spectrometry, albeit these fragment ions are mandatory for structural elucidation and high confidence lipid identification, especially in high throughput lipidomics workflows. Here we propose a nomenclature for the annotation of lipid fragment ions, describe its implementation and present a freely available web application, termed ALEX123 lipid calculator, that can be used to query a comprehensive database featuring curated lipid fragmentation information for more than 430,000 potential lipid molecules from 47 lipid classes covering five lipid categories. We note that the nomenclature is generic, extendable to stable isotope-labeled lipid molecules and applicable to automated annotation of fragment ions detected by most contemporary lipidomics platforms, including LC-MS/MS-based routines.

1 May 2017 in Journal of Chromatography B
Verified
Journal Article
Closed access
ATAlexander Triebl
Alexander Triebl
MTMartin Trötzmüller
Martin Trötzmüller
Jürgen HartlerJürgen Hartler
Jürgen Hartler
TSTatjana Stojakovic
Tatjana Stojakovic
Harald KöfelerHarald Köfeler
Harald Köfeler