Kenneth Casey

Dr. Kenneth Casey

Texas A&M AgriLife Research
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2005 in Transactions of the ASAE
Verified
Journal Article
Closed access
PDF file
YLY. Liang
Y. Liang
HXH. Xin
H. Xin
EWE. F. Wheeler
E. F. Wheeler
Richard GatesRichard Gates
Richard Gates
HLH. Li
H. Li
FZF. J. Zajaczkowski
F. J. Zajaczkowski

1 February 2013 in Atmospheric Environment
Verified
Journal Article
Closed access
DPDavid Parker
David Parker
JHJay Ham
Jay Ham
BWBryan Woodbury
Bryan Woodbury
LCLingshuang Cai
Lingshuang Cai
MSMindy Spiehs
Mindy Spiehs
ACAndy Cole
Andy Cole

1 January 2006 in Transactions of the ASABE
Verified
Journal Article
Closed access
PDF file
EWE. F. Wheeler
E. F. Wheeler
KCKenneth Casey
Kenneth Casey
Richard GatesRichard Gates
Richard Gates
HXH. Xin
H. Xin
JZJ. L. Zajaczkowski
J. L. Zajaczkowski
APA. J. Pescatore
A. J. Pescatore

1 January 2004 in Transactions of the ASAE
Verified
Journal Article
Closed access
PDF file
Richard GatesRichard Gates
Richard Gates
KCKenneth Casey
Kenneth Casey
HXH. Xin
H. Xin
EWE. F. Wheeler
E. F. Wheeler
JSJ. D. Simmons
J. D. Simmons

1 July 2011 in Journal of Environmental Quality
Verified
Journal Article
Closed access
PDF file
Richard W. ToddRichard W. Todd
Richard W. Todd
NCN. Andy Cole
N. Andy Cole
MRMarty B. Rhoades
Marty B. Rhoades
DPDavid B. Parker
David B. Parker
KCKenneth Casey
Kenneth Casey

1 October 2005 in Journal of Applied Poultry Research
Verified
Journal Article
Open access
PDF file
Richard GatesRichard Gates
Richard Gates
HXH. Xin
H. Xin
KCKenneth Casey
Kenneth Casey
YLY. Liang
Y. Liang
EWE. F. Wheeler
E. F. Wheeler
We present a measurement method for NH3 emissions from mechanically ventilated poultry buildings, which has been successfully used in a multistate, multidisciplinary research project to establish baseline values for the United States. To accurately determine building emission rate (ER, the product of pollutant concentration and exhaust airflow rate), accurate measurements must be made over representative periods and production phases. We present an innovative, low-cost, and accurate methodology that allows multiple buildings to be sampled in sequential order, provided that appropriate biosecurity measures are taken. Direct ventilation measurement is used in broiler houses, and in some layer operations, the number of fans is few enough that each fan can be individually calibrated in situ with a fan assessment numeration system device. For larger layer buildings with more than 15 fans, building ventilation is obtained from a tracer gas balance, utilizing CO2 generated by birds and feces. Other methods to determine building ventilation rate, which do not account for mechanical condition and degree of maintenance, both of which significantly affect actual fan capacity, introduce large errors. Twenty-eight portable monitoring units were fabricated and used for field acquisition of exhaust NH3 and CO2 concentrations and building static pressure. Ammonia is measured with redundant electrochemical sensors that are cyclically purged to eliminate errors caused by saturation from continuous exposure to air laden with NH3. The redundant NH3 unit minimizes missing data due to sensor failure.