Latifa Nabila Harfiya

Ms. Latifa Nabila Harfiya

National Central University
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Yung-Hui LiYung-Hui Li
Yung-Hui Li
Latifa Nabila HarfiyaLatifa Nabila Harfiya
Latifa Nabila Harfiya
KPKartika Purwandari
Kartika Purwandari
Yue-Der LinYue-Der Lin
Yue-Der Lin
Blood pressure monitoring is one avenue to monitor people’s health conditions. Early detection of abnormal blood pressure can help patients to get early treatment and reduce mortality associated with cardiovascular diseases. Therefore, it is very valuable to have a mechanism to perform real-time monitoring for blood pressure changes in patients. In this paper, we propose deep learning regression models using an electrocardiogram (ECG) and photoplethysmogram (PPG) for the real-time estimation of systolic blood pressure (SBP) and diastolic blood pressure (DBP) values. We use a bidirectional layer of long short-term memory (LSTM) as the first layer and add a residual connection inside each of the following layers of the LSTMs. We also perform experiments to compare the performance between the traditional machine learning methods, another existing deep learning model, and the proposed deep learning models using the dataset of Physionet’s multiparameter intelligent monitoring in intensive care II (MIMIC II) as the source of ECG and PPG signals as well as the arterial blood pressure (ABP) signal. The results show that the proposed model outperforms the existing methods and is able to achieve accurate estimation which is promising in order to be applied in clinical practice effectively.

23 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Latifa Nabila HarfiyaLatifa Nabila Harfiya
Latifa Nabila Harfiya
CCChing-Chun Chang
Ching-Chun Chang
Yung-Hui LiYung-Hui Li
Yung-Hui Li
Monitoring continuous BP signal is an important issue, because blood pressure (BP) varies over days, minutes, or even seconds for short-term cases. Most of photoplethysmography (PPG)-based BP estimation methods are susceptible to noise and only provides systolic blood pressure (SBP) and diastolic blood pressure (DBP) prediction. Here, instead of estimating a discrete value, we focus on different perspectives to estimate the whole waveform of BP. We propose a novel deep learning model to learn how to perform signal-to-signal translation from PPG to arterial blood pressure (ABP). Furthermore, using a raw PPG signal only as the input, the output of the proposed model is a continuous ABP signal. Based on the translated ABP signal, we extract the SBP and DBP values accordingly to ease the comparative evaluation. Our prediction results achieve average absolute error under 5 mmHg, with 70% confidence for SBP and 95% confidence for DBP without complex feature engineering. These results fulfill the standard from Association for the Advancement of Medical Instrumentation (AAMI) and the British Hypertension Society (BHS) with grade A. From the results, we believe that our model is applicable and potentially boosts the accuracy of an effective signal-to-signal continuous blood pressure estimation.

4 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
BHBill, Yan-Cheng Hsu
Bill, Yan-Cheng Hsu
Yung-Hui LiYung-Hui Li
Yung-Hui Li
CCChing-Chun Chang
Ching-Chun Chang
Latifa Nabila HarfiyaLatifa Nabila Harfiya
Latifa Nabila Harfiya
Due to the growing public awareness of cardiovascular disease (CVD), blood pressure (BP) estimation models have been developed based on physiological parameters extracted from both electrocardiograms (ECGs) and photoplethysmograms (PPGs). Still, in order to enhance the usability as well as reduce the sensor cost, researchers endeavor to establish a generalized BP estimation model using only PPG signals. In this paper, we propose a deep neural network model capable of extracting 32 features exclusively from PPG signals for BP estimation. The effectiveness and accuracy of our proposed model was evaluated by the root mean square error (RMSE), mean absolute error (MAE), the Association for the Advancement of Medical Instrumentation (AAMI) standard and the British Hypertension Society (BHS) standard. Experimental results showed that the RMSEs in systolic blood pressure (SBP) and diastolic blood pressure (DBP) are 4.643 mmHg and 3.307 mmHg, respectively, across 9000 subjects, with 80.63% of absolute errors among estimated SBP records lower than 5 mmHg and 90.19% of absolute errors among estimated DBP records lower than 5 mmHg. We demonstrated that our proposed model has remarkably high accuracy on the largest BP database found in the literature, which shows its effectiveness compared to some prior works.

1 January 2021 in Wireless Communications and Mobile Computing
Verified
Journal Article
Open access
PDF file
Yung-Hui LiYung-Hui Li
Yung-Hui Li
Latifa Nabila HarfiyaLatifa Nabila Harfiya
Latifa Nabila Harfiya
CCChing-Chun Chang
Ching-Chun Chang
Continuous blood pressure (BP) acquisition is critical to health monitoring of an individual. Photoplethysmography (PPG) is one of the most popular technologies in the last decade used for measuring blood pressure noninvasively. Several approaches have been carried out in various ways to utilize features extracted from PPG. In this study, we develop a continuous systolic and diastolic blood pressure (SBP and DBP) estimation mechanism without the need for any feature engineering. The raw PPG signal only got preprocessed before being fed to our model which mainly consists of one‐dimensional convolutional neural network (CNN) and bidirectional long short‐term memory (BiLSTM) network. We evaluate the resulting SBP and DBP value by the root‐mean‐squared error (RMSE) and mean absolute error (MAE). This study addresses the effectiveness of the model by outperforming the previous feature engineering‐based methods. We achieve RMSE of 11.503 and 6.525 for SBP and DBP, respectively, and MAE of 7.849 and 4.418 for SBP and DBP, respectively. The proposed method is expected to substantially enhance the current efficiency of healthcare IoT (Internet of Things) devices in BP monitoring using PPG signals only.

1 September 2021 in IEICE Transactions on Information and Systems
Verified
Journal Article
Closed access
PDF file
YLYung-Hui Li
Yung-Hui Li
Muhammad Saqlain AslamMuhammad Saqlain Aslam
Muhammad Saqlain Aslam
Latifa Nabila HarfiyaLatifa Nabila Harfiya
Latifa Nabila Harfiya
CCChing-Chun Chang
Ching-Chun Chang
The recent development of deep learning-based generative models has sharply intensified the interest in data synthesis and its applications. Data synthesis takes on an added importance especially for some pattern recognition tasks in which some classes of data are rare and difficult to collect. In an iris dataset, for instance, the minority class samples include images of eyes with glasses, oversized or undersized pupils, misaligned iris locations, and iris occluded or contaminated by eyelids, eyelashes, or lighting reflections. Such class-imbalanced datasets often result in biased classification performance. Generative adversarial networks (GANs) are one of the most promising frameworks that learn to generate synthetic data through a two-player minimax game between a generator and a discriminator. In this paper, we utilized the state-of-the-art conditional Wasserstein generative adversarial network with gradient penalty (CWGAN-GP) for generating the minority class of iris images which saves huge amount of cost of human labors for rare data collection. With our model, the researcher can generate as many iris images of rare cases as they want and it helps to develop any deep learning algorithm whenever large size of dataset is needed.

1 November 2017
Verified
Conference Paper
Closed access
Latifa Nabila HarfiyaLatifa Nabila Harfiya
Latifa Nabila Harfiya
AWAgus Wahyu Widodo
Agus Wahyu Widodo
RWRandy Cahya Wihandika
Randy Cahya Wihandika
In this paper, we consider the problem of forgery and misuse of signatures that happen oftentimes. We propose a framework for offline signature verification using pyramid histogram of oriented gradient (PHOG) as a feature. The PHOG feature is extracted from a binary image of a signature of the same size that does not have much noise and therefore before it is extracted, a preprocessing image is performed. There are various parameters that may affect the extraction of PHOG characteristics such as number of bin, level, angular range, and amount of training data used. Using the best obtained parameters of PHOG descriptor and modified K-nearest neighbor (MKNN) classifier we get a 1.5% false rejection rate on the dataset of the Indonesian signature image that we obtain and 3% on the Persian signature image dataset, while false acceptance rate obtained on the Indonesian signature image dataset is 14.499% and 39.5% on the Persian signature image dataset.