Young-Seok Park

Prof. Young-Seok Park

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2018 in Acta Odontologica Scandinavica
Verified
Journal Article
Closed access
HKHo-Beom Kwon
Ho-Beom Kwon
YPYoung-Seok Park
Young-Seok Park
JHJung-Suk Han
Jung-Suk Han
Augmentation reality technology offers virtual information in addition to that of the real environment and thus opens new possibilities in various fields. The medical applications of augmentation reality are generally concentrated on surgery types, including neurosurgery, laparoscopic surgery and plastic surgery. Augmentation reality technology is also widely used in medical education and training. In dentistry, oral and maxillofacial surgery is the primary area of use, where dental implant placement and orthognathic surgery are the most frequent applications. Recent technological advancements are enabling new applications of restorative dentistry, orthodontics and endodontics. This review briefly summarizes the history, definitions, features, and components of augmented reality technology and discusses its applications and future perspectives in dentistry.

18 March 2021 in Materials
Verified
Journal Article
Open access
PDF file
WMWonjoon Moon
Wonjoon Moon
SKSeihwan Kim
Seihwan Kim
BLBum-Soon Lim
Bum-Soon Lim
YPYoung-Seok Park
Young-Seok Park
RKRyan Jin Young Kim
Ryan Jin Young Kim
SCShin Hye Chung
Shin Hye Chung
With the advent of 3D printing technologies in dentistry, the optimization of printing conditions has been of great interest, so this study analyzed the accuracy of 3D-printed temporary restorations of different sizes produced by digital light processing (DLP) and liquid crystal display (LCD) printers. Temporary restorations of 2-unit, 3-unit, 5-unit, 6-unit, and full-arch cases were designed and printed from a DLP printer using NextDent C&B or an LCD printer using Mazic D Temp (n = 10 each). The restorations were scanned, and each restoration standard tessellation language (STL) file was superimposed on the reference STL file, by the alignment functions, to evaluate the trueness through whole/point deviation. In the whole-deviation analysis, the root-mean-square (RMS) values were significantly higher in the 6-unit and full-arch cases for the DLP printer and in the 5-unit, 6-unit, and full-arch cases for the LCD printer. The significant difference between DLP and LCD printers was found in the 5-unit and full-arch cases, where the DLP printer exhibited lower RMS values. Color mapping demonstrated less shrinkage in the DLP printer. In the point deviation analysis, a significant difference in direction was exhibited in all the restorations from the DLP printer but only in some cases from the LCD printer. Within the limitations of this study, 3D printing was most accurate with less deviation and shrinkage when a DLP printer was used for short-unit restorations.

13 February 2013 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
WSWon‐Jun Shon
Won‐Jun Shon
SCShin Hye Chung
Shin Hye Chung
HKHong‐Kyun Kim
Hong‐Kyun Kim
GHGeum‐Jun Han
Geum‐Jun Han
BCByeong-Hoon Cho
Byeong-Hoon Cho
YPYoung-Seok Park
Young-Seok Park

29 January 2018 in Canadian Journal of Gastroenterology and Hepatology
Verified
Journal Article
Open access
PDF file
KKKyeong-Ah Kwak
Kyeong-Ah Kwak
HCHyun-Jae Cho
Hyun-Jae Cho
JYJin-Young Yang
Jin-Young Yang
YPYoung-Seok Park
Young-Seok Park
Liver cirrhosis is a major cause of mortality and a common end of various progressive liver diseases. Since the effective treatment is currently limited to liver transplantation, stem cell-based therapy as an alternative has attracted interest due to promising results from preclinical and clinical studies. However, there is still much to be understood regarding the precise mechanisms of action. A number of stem cells from different origins have been employed for hepatic regeneration with different degrees of success. The present review presents a synopsis of stem cell research for the treatment of patients with liver cirrhosis according to the stem cell type. Clinical trials to date are summarized briefly. Finally, issues to be resolved and future perspectives are discussed with regard to clinical applications.

20 December 2015 in Stem Cells International
Verified
Journal Article
Open access
PDF file
YPYun-Jong Park
Yun-Jong Park
SCSeunghee Cha
Seunghee Cha
YPYoung-Seok Park
Young-Seok Park
Tooth derived stem cells or dental stem cells are categorized according to the location from which they are isolated and represent a promising source of cells for regenerative medicine. Originally, as one kind of mesenchymal stem cells, they are considered an alternative of bone marrow stromal cells. They share many commonalties but maintain differences. Considering their original function in development and the homeostasis of tooth structures, many applications of these cells in dentistry have aimed at tooth structure regeneration; however, the application in other than tooth structures has been attempted extensively. The availability from discarded or removed teeth can be an innate benefit as a source of autologous cells. Their origin from the neural crest results in exploitation of neurological and numerous other applications. This review briefly highlights current and future perspectives of the regenerative applications of tooth derived stem cells in areas beyond tooth regeneration.

1 August 2022 in BioMed Research International
Verified
Journal Article
Open access
PDF file
VTVan Mai Truong
Van Mai Truong
SKSoyeon Kim
Soyeon Kim
JKJaeheon Kim
Jaeheon Kim
JLJoo Won Lee
Joo Won Lee
YPYoung-Seok Park
Young-Seok Park
Miniscrew has been used widely as an effective orthodontic anchorage with reliable stationary quality, ease of insertion and removal techniques, immediate or early loading, flexibility in site insertion, less trauma, minimal patient cooperation, and lower price. Nonetheless, it is not free of complications, and they could impact not only the miniscrew success rate but also patients’ oral health. In this article, literature was searched and reviewed electronically as well as manually to evaluate the complications of orthodontic miniscrew. The selected articles are analyzed and subcategorized into complications during and after insertion, under loading, and during and after removal along with treatment if needed according to the time. In addition, the noteworthy associated factors such as the insertion and removal procedures, characteristics of both regional and local anatomic structures, and features of the miniscrew itself that play a significant role in the performance of miniscrews are also discussed based on literature evidence. Clinicians should notice these complications and their related factors to make a proper treatment plan with better outcomes.