Grace Lin

Ms. Grace Lin

AIT-Austrian Institute of Technology

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2021 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
GLGrace Lin
Grace Lin
EKErik Küng
Erik Küng
MSMerima Smajlhodžić-Deljo
Merima Smajlhodžić-Deljo
SDSandra Domazet
Sandra Domazet
HFHeinz P. Friedl
Heinz P. Friedl
Winfried NeuhausWinfried Neuhaus
Winfried Neuhaus
C-reactive protein (CRP) is a commonly used serum biomarker for detecting sepsis in neonates. After the onset of sepsis, serial measurements are necessary to monitor disease progression; therefore, a non-invasive detection method is beneficial for neonatal well-being. While some studies have shown a correlation between serum and salivary CRP levels in septic neonates, the causal link behind this correlation remains unclear. To investigate this relationship, CRP was examined in serum and saliva samples from 18 septic neonates and compared with saliva samples from 22 healthy neonates. While the measured blood and saliva concentrations of the septic neonates varied individually, a correlation of CRP levels between serum and saliva samples was observed over time. To clarify the presence of active transport of CRP across the blood–salivary barrier (BSB), transport studies were performed with CRP using in vitro models of oral mucosa and submandibular salivary gland epithelium. The results showed enhanced transport toward saliva in both models, supporting the clinical relevance for salivary CRP as a biomarker. Furthermore, CRP regulated the expression of the receptor for advanced glycation end products (RAGE) and the addition of soluble RAGE during the transport studies indicated a RAGE-dependent transport process for CRP from blood to saliva.

23 August 2020 in Biomedicines
Verified
Journal Article
Open access
PDF file
GLGrace Lin
Grace Lin
MSMerima Smajlhodžić-Deljo
Merima Smajlhodžić-Deljo
ABAnna-Maria Bandian
Anna-Maria Bandian
HFHeinz-Peter Friedl
Heinz-Peter Friedl
TLTamara Leitgeb
Tamara Leitgeb
Winfried NeuhausWinfried Neuhaus
Winfried Neuhaus
The blood–saliva barrier (BSB) consists of the sum of the epithelial cell layers of the oral mucosa and salivary glands. In vitro models of the BSB are inevitable to investigate and understand the transport of salivary biomarkers from blood to saliva. Up to now, standardized, cell line-based models of the epithelium of the submandibular salivary gland are still missing for this purpose. Therefore, we established epithelial barrier models of the submandibular gland derived from human cell line HTB-41 (A-253). Single clone isolation resulted in five different clones (B2, B4, B9, D3, and F11). Clones were compared to the parental cell line HTB-41 using measurements of the transepithelial electrical resistance (TEER), paracellular marker permeability assays and analysis of marker expression for acinar, ductal, and myoepithelial cells. Two clones (B9, D3) were characterized to be of acinar origin, one clone (F11) to be of myoepithelial origin and one isolation (B4) derived from two cells, to be presumably a mixture of acinar and ductal origin. Clone B2, presumably of ductal origin, showed a significantly higher paracellular barrier compared to other clones and parental HTB-41. The distinct molecular identity of clone B2 was confirmed by immunofluorescent staining, qPCR, and flow cytometry. Experiments with ferritin, a biomarker for iron storage, demonstrated the applicability of the selected model based on clone B2 for transport studies. In conclusion, five different clones originating from the submandibular gland cell line HTB-41 were successfully characterized and established as epithelial barrier models. Studies with the model based on the tightest clone B2 confirmed its suitability for transport studies in biomarker research.

25 July 2018 in bioRxiv
Verified
Preprint
Open access
PDF file
ARAnja Patricia Ramme
Anja Patricia Ramme
LKLeopold Koenig
Leopold Koenig
THTobias Hasenberg
Tobias Hasenberg
CSChristine Schwenk
Christine Schwenk
CMCorinna Magauer
Corinna Magauer
EDEva-Maria Dehne
Eva-Maria Dehne
Microphysiological systems are fundamental for progressing towards a global paradigm shift in drug development through the generation of patient-on-a-chip models. An increasing number of single- and multi-organ systems have been adopted by the pharmaceutical and cosmetic industries for predictive substance testing. These models run on heterogeneous tissues and cell types from different donors. However, a patient is an individual. Therefore, patient-on-a-chip systems need to be built from tissues from one autologous source. Individual on-chip organ differentiation from a single induced pluripotent stem cell source could provide a solution to this challenge. We designed a four-organ chip based on human physiology. It enables the interconnection of miniaturized human intestine, liver, brain and kidney equivalents. All four organ models were predifferentiated from induced pluripotent stem cells from the same healthy donor and integrated into the microphysiological system. The cross talk led to further differentiation over a 14-day cultivation period under pulsatile blood flow conditions in one common medium deprived of growth factors. This model platform will pave the way for disease induction and subsequent drug testing.