This guidance document has been prepared on behalf of the International Council for Standardization in Haematology (ICSH). The aim of the document is to provide guidance and recommendations for the processing of citrated blood samples for coagulation tests in clinical laboratories in all regions of the world. The following areas are included in this document: Sample transport including use of pneumatic tubes systems; clots in citrated samples; centrifugation; primary tube storage and stability; interfering substances including haemolysis, icterus and lipaemia; secondary aliquots—transport, storage and processing; preanalytical variables for platelet function testing. The following areas are excluded from this document, but are included in an associated ICSH document addressing collection of samples for coagulation tests in clinical laboratories; ordering tests; sample collection tube and anticoagulant; preparation of the patient; sample collection device; venous stasis before sample collection; order of draw when different sample types are collected; sample labelling; blood‐to‐anticoagulant ratio (tube filling); influence of haematocrit. The recommendations are based on published data in peer‐reviewed literature and expert opinion.
Summary: The wide availability of fibrinogen estimations based on the prothrombin time (PT-Fg) has caused concern about the variability and clinical utility of fibrinogen assays. In a multi-centre study, we investigated fibrinogen assays using various reagents and analysers. Clauss assays generally gave good agreement, although one reagent gave 15–30% higher values in DIC and thrombolysis. Two commercial reference preparations had much lower potencies than the manufacturers declared, and plasma turbidity influenced parallelism in some Clauss assays. PT-Fg assays gave higher values than Clauss and showed calibrant dependent effects, the degree of disparity correlating with calibrant and test sample turbidity. Analyser and thromboplastin dependent differences were noted. The relationship between Clauss and PT-Fg assays was sigmoid, and the plateau of maximal PT-Fg differed by about 2 g/l between reagents. ELISA and immunonephelometric assays correlated well, but with a high degree of scatter. Antigen levels were higher than Clauss, but slightly lower than PT-Fg assays, which appeared to be influenced by degraded fibrinogen. Clauss assays are generally reproducible between centres, analysers and reagents, but PT-Fg assays are not reliable in clinical settings.
7 June 2021 in International Journal of Laboratory Hematology
This guidance document has been prepared on behalf of the International Council for Standardisation in Haematology (ICSH). The aim of the document is to provide guidance and recommendations for collection of blood samples for coagulation tests in clinical laboratories throughout the world. The following processes will be covered: ordering tests, sample collection tube and anticoagulant, patient preparation, sample collection device, venous stasis before sample collection, order of draw when different sample types need to be collected, sample labelling, blood‐to‐anticoagulant ratio (tube filling) and influence of haematocrit. The following areas are excluded from this document, but are included in an associated ICSH document addressing processing of samples for coagulation tests in clinical laboratories: sample transport and primary tube sample stability; centrifugation; interfering substances including haemolysis, icterus and lipaemia; secondary aliquots—transport and storage; and preanalytical variables for platelet function testing. The recommendations are based on published data in peer‐reviewed literature and expert opinion.
16 July 2020 in International Journal of Laboratory Hematology
This guidance document was prepared on behalf of the International Council for Standardization in Haematology (ICSH), by the ADAMTS13 Assay Working Group, which comprises an international group of both clinical and laboratory experts. The document provides recommendations on best practice for the performance of ADAMTS13 assays in clinical laboratories. ADAMTS13 assays support the differential diagnosis of thrombotic microangiopathies and have utility in the management of thrombotic thrombocytopenic purpura (TTP). There are three types of assay: activity, antigen and autoantibody/inhibitor assays. Methods for activity assays differ in terms of sensitivity, specificity, precision and turnaround time. The most widely used assays involve VWF peptide substrates and either chromogenic ELISA or FRET techniques, although chemiluminescence assays and rapid screening tests have recently become available. Tests for autoantibodies and inhibitors allow confirmation of acquired, immune‐mediated TTP, while antigen assays may be useful in congenital TTP and as prognostic markers. In this document, we have attempted to describe ADAMTS13 assays and the conditions that affect them, as well as: blood collection, sample processing, quality control, standardization and clinical utility; recognizing that laboratories in different parts of the world have varying levels of sophistication. The recommendations are based on expert opinion, published literature and good clinical laboratory practice.