Zhaoxiang Peng

Dr. Zhaoxiang Peng

Ningbo Medical Center Lihuili Hospital, Ningbo, Zhejiang, China
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2023 in International Journal of Biological Macromolecules
Verified
Journal Article
Closed access
LMLe Ma
Le Ma
WJWenwen Jiang
Wenwen Jiang
XXXiaowei Xun
Xiaowei Xun
MLMingzhuo Liu
Mingzhuo Liu
XHXiao Han
Xiao Han
HAHaiyong Ao
Haiyong Ao

24 April 2019 in Royal Society Open Science
Verified
Journal Article
Open access
ZPZhaoxiang Peng
Zhaoxiang Peng
JNJiahua Ni
Jiahua Ni
A highly ordered TiO 2 nanotube array has been prepared on a commercial pure titanium substrate in a hydrofluoric (HF) electrolyte using a DC power source through two-step anodic oxidation. The morphology, composition, wettability and surface energy of the nanotube array have been characterized by using a field-emission scanning electron microscope (FE-SEM), a transmission electron microscope (JEM-2010) with energy-dispersive X-ray spectrometer EDX (INCA OXFORD), X-ray diffraction method, an atomic force microscope (AFM), an optical contact angle measuring device and the Owens method with two liquids. The electrochemical behaviours of anodic oxidation films with different structures have been investigated in Sodium Lactate Ringer's Injection at 37±1°C by potentiodynamic polarization curve and electrochemical impedance spectroscopy. The formation mechanism of the nanotube array and the advantages of two-step oxidation have been discussed according to the experimental observation and the characterized results. Meanwhile, the structural changes of nanotubes are analysed according to the results of impedance spectroscopy. Cytotoxicity testing and cell adhesion and proliferation have been studied in order to evaluate the bioactivity of the nanotube array film. The diameters of nanotubes are in the range of 120–140 nm. The nanotube surface shows better wettability and higher surface energy compared to the bare substrate. The nanotube surface exhibits a wide passivation range and good corrosion resistance. The growth of the nanotube array is the result of the combined action of the anodization and field-assisted dissolution. The nanotube array by two-step oxidation becomes more regular and orderly. Moreover, the nanotube array surface is non-toxic and favourable to cell adhesion and proliferation. Such nanotube array films are expected to have significant biomedical applications.

24 May 2023 in Journal of Orthopaedic Translation
Verified
Journal Article
Open access
JDJieyang Dong
Jieyang Dong
JZJiaqi Zhong
Jiaqi Zhong
RHRuixia Hou
Ruixia Hou
XHXiaodong Hu
Xiaodong Hu
YCYujiong Chen
Yujiong Chen
ZPZhaoxiang Peng
Zhaoxiang Peng
Pure magnesium-based ortho-implants have a number of advantages. However, vital parameters like degradation rate and biocompatibility still call for significant improvement. In this study, poly (1,3-trimethylene carbonate) (PTMC) and polydopamine (PDA) bilayer and micro arc oxidation composite coatings were prepared successively on magnesium surface by immersion method and microarc oxidation. Its corrosion resistance and biocompatibility were evaluated by in vitro corrosion tests, cellular compatibility experiments, and in vivo animal experiments. In vitro experiments demonstrated that the composite coating provides excellent corrosion protection and biocompatibility. Animal studies demonstrated that the composite coating slowed the degradation of the implant and was not toxic to animal viscera. In conclusion, the inorganic-organic composite coating proposed in this study provided good corrosion resistance and enhanced biocompatibility for pure magnesium implants. The translational potential of this article is to develop an anti-corrosion composite coating on a pure magnesium surface and to verify the viability of its use in animal models. It is hoped to open up a new approach to the design of new degradable orthopedic magnesium-based implants.

10 September 2022 in Journal of Orthopaedic Translation
Verified
Journal Article
Open access
YCYudie Chen
Yudie Chen
YSYu Sun
Yu Sun
Xinhui WuXinhui Wu
Xinhui Wu
JLJie Lou
Jie Lou
XZXiaonong Zhang
Xiaonong Zhang
ZPZhaoxiang Peng
Zhaoxiang Peng
Rotator cuff tear has become one of the diseases affecting people's living quality. Conventional anchor materials such as titanium alloy and poly-lactic acid can lead to postoperative complications like bone defects and aseptic inflammation. Magnesium (Mg)-based implants are biodegradable and biocompatible, with strong potential to be applied in orthopaedics. In this study, we developed a high-purity (HP) Mg suture anchor and studied its mechanical properties and degradation behavior in vitro. Furthermore, we described the use of high-purity Mg to prepare suture anchor for the rotator cuff repair in sheep. The in vitro tests showed that HP Mg suture anchor possess proper degradation behavior and appropriate mechanical property. Animal experiment indicated that HP Mg suture anchor provided reliable anchoring function in 12 weeks and showed no toxic effect on animal organs. In summary, the HP Mg anchor presented in this study had favorable mechanical property and biosecurity. The translational potential of this article: The translational potential of this article is to use high-purity Mg to develop a degradable suture anchor and verify the feasibility of the application in animal model. This study provides a basis for further research on the clinical application of biodegradable high-purity Mg suture anchor.

20 March 2022 in Coatings
Verified
Journal Article
Open access
PDF file
XWXinhui Wu
Xinhui Wu
HAHaiyong Ao
Haiyong Ao
ZHZhaoru He
Zhaoru He
QWQun Wang
Qun Wang
ZPZhaoxiang Peng
Zhaoxiang Peng
In the past few decades, titanium and its alloys have been widely used in the orthopaedic field. However, because titanium is bioinert and lacks antibacterial properties, infection may happen when bacteria attach to implant surfaces and form biofilms. It has been studied that some naturally existing micron-scale topographies can reduce bacterial attachment such as cicada wings and gecko skins. The aim of this in vitro study was to find an implant with good biocompatibility and antimicrobial properties by the modification of micron-scale topographies. In this paper, a femtosecond laser was used to provide microtopography coatings on Ti substrates. The surface morphology of Ti substrates was observed by scanning electron microscopy (SEM). XPS was used to fulfil the chemical compositional analysis. The surface wettability was measured by contact angle measurement system. The effect of microtopography coatings with different surface microstructures on bacterial activities and bone marrow mesenchymal stem cells (BMSC) functions was investigated. The results of in vitro study revealed that microtopography coatings restrain the adhesion of Staphylococcus aureus (S. aureus) and Staphylococcus epidermidis (S. epidermidis), which are common pathogens of orthopaedic implant infections. In addition, microtopography coatings stimulated BMSC adhesion and proliferation. Our studies suggest that a microtopography-coated sample modified by femtosecond laser showed promising antibacterial properties and favourable biocompatibility. The femtosecond laser technique provides an accurate and valid way to produce microtopography coatings with outstanding biocompatibility and antimicrobial properties, and could be widely used to modify the surface of orthopaedic metal implants with great potential.

29 February 2024 in Frontiers in Artificial Intelligence
Verified
Journal Article
Open access
ZZZhewei Zhang
Zhewei Zhang
CKChunhai Ke
Chunhai Ke
ZZZhibin Zhang
Zhibin Zhang
YCYujiong Chen
Yujiong Chen
HWHangbin Weng
Hangbin Weng
ZPZhaoxiang Peng
Zhaoxiang Peng
The application of artificial intelligence technology in the medical field has become increasingly prevalent, yet there remains significant room for exploration in its deep implementation. Within the field of orthopedics, which integrates closely with AI due to its extensive data requirements, rotator cuff injuries are a commonly encountered condition in joint motion. One of the most severe complications following rotator cuff repair surgery is the recurrence of tears, which has a significant impact on both patients and healthcare professionals. To address this issue, we utilized the innovative EV-GCN algorithm to train a predictive model. We collected medical records of 1,631 patients who underwent rotator cuff repair surgery at a single center over a span of 5 years. In the end, our model successfully predicted postoperative re-tear before the surgery using 62 preoperative variables with an accuracy of 96.93%, and achieved an accuracy of 79.55% on an independent external dataset of 518 cases from other centers. This model outperforms human doctors in predicting outcomes with high accuracy. Through this methodology and research, our aim is to utilize preoperative prediction models to assist in making informed medical decisions during and after surgery, leading to improved treatment effectiveness. This research method and strategy can be applied to other medical fields, and the research findings can assist in making healthcare decisions.