Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Unidad Mixta Universitat Politècnica de València—Universitat de València, Camí de Vera s/n, 46022 Valencia, Spain
Dr. Nicolás Laguarda-Miró
Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Unidad Mixta Universitat Politècnica de València—Universitat de València, Camí de Vera s/n, 46022 Valencia, Spain
This paper reports on the fabrication of a capacitive-type relative humidity (RH) sensor using screen printing processes for electrode film deposition. The applied measurement method based on microcontrollers is also reported. In this specific case, the microcontroller is used to measure RH by means of a capacitive sensor with a simple low-cost electronic system. In addition, a comparison between two different types of polyester substrates [Melinex (DuPont) and CG3460 (3M)] is shown. Both polyester substrates have similar properties, and only the thickness is different (175 μm for Melinex and 100 μm for CG3460). A nonlineal response has been obtained in this type of sensors. In order to linearize the response and reduce the external hardware, an artificial neural network embedded into the microcontroller has been used.
1 December 2011 in Sensors and Actuators A: Physical
A new electronic tongue to monitor the presence of glyphosate (a non-selective systemic herbicide) has been developed. It is based on pulse voltammetry and consists in an array of three working electrodes (Pt, Co and Cu) encapsulated on a methacrylate cylinder. The electrochemical response of the sensing array was characteristic of the presence of glyphosate in buffered water (phosphate buffer 0.1 mol·dm−3, pH 6.7). Rotating disc electrode (RDE) studies were carried out with Pt, Co and Cu electrodes in water at room temperature and at pH 6.7 using 0.1 mol·dm−3 of phosphate as a buffer. In the presence of glyphosate, the corrosion current of the Cu and Co electrodes increased significantly, probably due to the formation of Cu2+ or Co2+ complexes. The pulse array waveform for the voltammetric tongue was designed by taking into account some of the redox processes observed in the electrochemical studies. The PCA statistical analysis required four dimensions to explain 95% of variance. Moreover, a two-dimensional representation of the two principal components differentiated the water mixtures containing glyphosate. Furthermore, the PLS statistical analyses allowed the creation of a model to correlate the electrochemical response of the electrodes with glyphosate concentrations, even in the presence of potential interferents such as humic acids and Ca2+. The system offers a PLS prediction model for glyphosate detection with values of 098, −2.3 × 10−5 and 0.94 for the slope, the intercept and the regression coefficient, respectively, which is in agreement with the good fit between the predicted and measured concentrations. The results suggest the feasibility of this system to help develop electronic tongues for glyphosate detection.
Lemon is the most sensitive citrus fruit to cold. Therefore, it is of capital importance to detect and avoid temperatures that could damage the fruit both when it is still in the tree and in its subsequent commercialization. In order to rapidly identify frost damage in this fruit, a system based on the electrochemical impedance spectroscopy technique (EIS) was used. This system consists of a signal generator device associated with a personal computer (PC) to control the system and a double-needle stainless steel electrode. Tests with a set of fruits both natural and subsequently frozen-thawed allowed us to differentiate the behavior of the impedance value depending on whether the sample had been previously frozen or not by means of a single principal components analysis (PCA) and a partial least squares discriminant analysis (PLS-DA). Artificial neural networks (ANNs) were used to generate a prediction model able to identify the damaged fruits just 24 hours after the cold phenomenon occurred, with sufficient robustness and reliability (CCR = 100%).
1 October 2014 in Sensors and Actuators B: Chemical
This study focuses on the analysis and early detection of freeze-damage in tangerines using a specific double-needle sensor and Electrochemical Impedance Spectroscopy (EIS). Freeze damage may appear in citrus fruits both in the field and in postharvest processes resulting in quality loss and a difficult commercialization of the fruit. EIS has been used to test a set of homogeneous tangerine samples both fresh and later frozen to analyze electrochemical and biological differences. A double-needle electrode associated to a specifically designed electronic device and software has been designed and used to send an AC electric sinusoidal signal 1 V in amplitude and frequency range [100Hz to 1MHz] to the analyzed samples and then receive the electrochemical impedance response. EIS measurements lead to distinct values of both impedance module and phase of fresh and frozen samples over a wide frequency range. Statistical treatment of the received data set by Principal Components Analysis (PCA) and Partial Least Squares Discriminant Analysis (PLS-DA) shows a clear classification of the samples depending on the experienced freeze phenomenon, with high sensitivity (1.00), specificity (≥ 0.95) and confidence level (95%). Later Artificial Neural Networks (ANN) analysis based on 20-3-1 architecture has allowed to create a mathematical prediction model able to correctly classify 100% of the analyzed samples (CCR =100% for training, validation and test phases, and overall classification), being fast, easy, robust and reliable, and an interesting alternative method to the traditional laboratory analyses.