Guanglu Wu

Dr. Guanglu Wu

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
SCSophie Coffey
Sophie Coffey
VTVictor Timmers
Victor Timmers
RLRui Li
Rui Li
GWGuanglu Wu
Guanglu Wu
Agusti Egea AlvarezAgusti Egea Alvarez
Agusti Egea Alvarez
This paper presents a complete review of MVDC applications and their required technologies. Four main MVDC applications were investigated: rail, shipboard systems, distribution grids, and offshore collection systems. For each application, the voltage and power levels, grid structures, converter topologies, and protection and control structure were reviewed. Case studies of the varying applications as well as the literature were analyzed to ascertain the common trends and to review suggested future topologies. For rail, ship, and distribution systems, the technology and ability to implement MVDC grids is available, and there are already a number of case studies. Offshore wind collection systems, however, are yet able to be implemented. Across the four applications, the MVDC voltages ranged from 5–50 kV DC and tens of MW, with some papers suggesting an upper limit of 100 kV DC and hundreds of MV for distribution networks and offshore wind farm applications. This enables the use of varying technologies at both the lower and high voltage ranges, giving flexibility in the choice of topology that is required required.

17 July 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
GWGuanglu Wu
Guanglu Wu
HSHuadong Sun
Huadong Sun
XZXi Zhang
Xi Zhang
Agusti Egea AlvarezAgusti Egea Alvarez
Agusti Egea Alvarez
BZBing Zhao
Bing Zhao
XZXiaoxin Zhou
Xiaoxin Zhou
This paper studies the dynamic behaviors of weak-grid-tied VSCs with simplified transfer functions, which provides an accurate stability analysis and useful indications for tuning system parameters. A reduced-order multi-input multi-output (MIMO) transfer function that contains four single-input single-output (SISO) transfer functions for the weak-grid-tied VSC is first presented. It is found that the four SISO transfer functions share the same equivalent open-loop transfer function, i.e., the same stability conclusion. The Bode plots of the equivalent open-loop transfer function show that the inner current loop behaves as a band-pass filter whose maximum gain is approximately at the frequency of the PLL's bandwidth. By stability criterion, the harmonic amplification and instability occur when its maximum gain exceeds 0dB caused by high PLL's bandwidth, large grid impedance or high active power. It is also found that the target system is less stable when it works as an inverter than as a rectifier, due to the risk of the local positive feedback in the inverter mode. An effective criterion is further proposed to guide the selection of a proper PLL's bandwidth to ensure the stability of the VSC system. Simulation results validate the correctness of the analysis and the efficacy of the criterion.

22 September 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
YLYingbiao Li
Yingbiao Li
XWXiongfei Wang
Xiongfei Wang
JGJianbo Guo
Jianbo Guo
HWHeng Wu
Heng Wu
BZBing Zhao
Bing Zhao
TWTiezhu Wang
Tiezhu Wang
This article analyzes the transient stability of an offshore wind farm connected via modular multilevel converter (MMC)-based high-voltage direct-current transmission system. The wind farm is composed by full-scale type-4 wind turbines, whereas short-circuit faults occurring in between the MMC and wind farm are considered. The MMC tends to be switched to the current limiting mode or the overmodulation mode during the ac-side fault, which further interacts with the control systems of wind turbines, complicating the transient stability problem of the system. Hence, in this work the parametric impacts of the phase-locked loop of wind turbine converters and over-current/-modulation limiters of the MMC are revealed analytically, and further corroborated by time-domain simulations.

26 July 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
GWGuanglu Wu
Guanglu Wu
HSHuadong Sun
Huadong Sun
BZBing Zhao
Bing Zhao
SXShiyun Xu
Shiyun Xu
XZXi Zhang
Xi Zhang
XZXiaoxin Zhou
Xiaoxin Zhou
Low-frequency oscillations have been reported in several weak-grids-connected voltage-source-converter(VSC) systems. Although efforts have been devoted to understanding the parametric and sensitivity impact of the VSC controller gains, a general formulation of the oscillation mechanism is still missing. Using transfer function dynamic modelling approach, we find that the outer loop active power control's bandwidth mainly determines the oscillation frequency. The PLL introduces a large phase lag around the frequency of the PLL bandwidth in weak grids which decreases the oscillation damping. A simple but effective PI+Clegg integrator (CI) compensator is proposed to replace the standard outer loop active power controller compensating the PLL's phase delay and increasing the oscillation damping. The results are verified in a real time digital simulator.

29 October 2020 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
GWGuanglu Wu
Guanglu Wu
BZBing Zhao
Bing Zhao
XZXi Zhang
Xi Zhang
SWShanshan Wang
Shanshan Wang
Agusti Egea AlvarezAgusti Egea Alvarez
Agusti Egea Alvarez
XZXiaoxin Zhou
Xiaoxin Zhou
Right-half-plain (RHP) zeros can significantly deteriorate a control system's dynamic performances as it exhibits non-minimum-phase behaviors. In this paper, we investigate the occurrence mechanism of RHP zeros in weak-grid-tied VSCs as well as provide guidance for minimizing their effects. A reduced-order multi-input multi-output (MIMO) transfer function of the weak-grid-tied VSC is firstly obtained. Then, the single-input single-output (SISO) transfer function to study the impact of the RHP zeros on the power response is further derived. The existence of RHP zeros is examined by applying the Routh criterion on the numerator of the SISO open-loop transfer function. We find that RHP zeros can exist either when the VSC works as an inverter or a rectifier. Furthermore, large grid impedance values as well as operation points with high active power values can result in a non-minimum-phase system. It is also shown that RHP zeros limit the minimum PLL bandwidth. Simulation results and RTDS experiments validate the correctness of the analysis and the conclusions obtained.

29 January 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YLYingbiao Li
Yingbiao Li
JGJianbo Guo
Jianbo Guo
HWHeng Wu
Heng Wu
XWXiongfei Wang
Xiongfei Wang
BZBing Zhao
Bing Zhao
GWGuanglu Wu
Guanglu Wu
This paper presents a design-oriented analysis on the voltage stability and the transient fault current limitation of voltage-controlled modular multilevel converter (MMC) with L-filters. First, a dual-loop voltage control based on the L-filter plant is systematically designed, where the upper limits of controller parameters for ensuring the small-signal stability are identified. Then, considering the transient fault current limitation during faults, the lower boundaries of the inner current controller parameters are derived. Within the region of allowed controller parameters, the optimization is further made to minimize the closed-loop output impedance of MMC, which enhances the robustness of MMC output voltage against the load current disturbance. Lastly, the time-domain simulations corroborate the theoretical analysis.