Serafina Calarco

Dr. Serafina Calarco

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SCSerafina Calarco
Serafina Calarco
BFB Leticia Fernandez-Carballo
B Leticia Fernandez-Carballo
TKThomas Keller
Thomas Keller
SWStephan Weber
Stephan Weber
MJMeike Jakobi
Meike Jakobi
SDSabine Dittrich
Sabine Dittrich
Accurate and precise point-of-care (POC) testing for C-reactive protein (CRP) can help support healthcare providers in the clinical management of patients. Here, we compared the analytical performance of 17 commercially available POC CRP tests to enable more decentralized use of the tool. The following CRP tests were evaluated. Eight quantitative tests: QuikRead go (Aidian), INCLIX (Sugentech), Spinit (Biosurfit), LS4000 (Lansionbio), GS 1200 (Gensure Biotech), Standard F200 (SD Biosensor), Epithod 616 (DxGen), IFP-3000 (Xincheng Biological); and nine semi-quantitative tests: Actim CRP (ACTIM), NADAL Dipstick (nal von minden), NADAL cassette (nal von minden), ALLTEST Dipstick (Hangzhou Alltest Biotech), ALLTEST Cassette cut-off 10-40-80 (Hangzhou Alltest Biotech), ALLTEST Cassette cut-off 10–30 (Hangzhou Alltest Biotech), Biotest (Hangzhou Biotest Biotech), BTNX Quad Line (BTNX), BTNX Tri Line (BTNX). Stored samples (n = 660) had previously been tested for CRP using Cobas 8000 Modular analyzer (Roche Diagnostics International AG, Rotkreuz, Switzerland (reference standards). CRP values represented the clinically relevant range (10–100 mg/L) and were grouped into four categories ( 80mg/L) for majority of the semi-quantitative tests. Among the eight quantitative POC tests evaluated, QuikRead go and Spinit exhibited better agreement with the reference method, showing slopes of 0.963 and 0.921, respectively. Semi-quantitative tests with the four categories showed a poor percentage agreement for the intermediate categories and higher percentage agreement for the lower and upper limit categories. Analytical performance varied considerably for the semi-quantitative tests, especially among the different categories of CRP values. Our findings suggest that quantitative tests might represent the best choice for a variety of use cases, as they can be used across a broad range of CRP categories.

19 September 2020 in Cells
Verified
Journal Article
Open access
PDF file
SGSujay Guha
Sujay Guha
SCSerafina Calarco
Serafina Calarco
MGM. Salomé Gachet
M. Salomé Gachet
Jürg GertschJürg Gertsch
Jürg Gertsch
In eukaryotes, the C20:4 polyunsaturated fatty acid arachidonic acid (AA) plays important roles as a phospholipid component, signaling molecule and precursor of the endocannabinoid-prostanoid axis. Accordingly, the absence of AA causes detrimental effects. Here, compensatory mechanisms involved in AA deficiency in Caenorhabditis elegans were investigated. We show that the ω-3 C20:4 polyunsaturated fatty acid juniperonic acid (JuA) is generated in the C. elegans fat-3(wa22) mutant, which lacks Δ6 desaturase activity and cannot generate AA and ω-3 AA. JuA partially rescued the loss of function of AA in growth and development. Additionally, we observed that supplementation of AA and ω-3 AA modulates lifespan of fat-3(wa22) mutants. We described a feasible biosynthetic pathway that leads to the generation of JuA from α-linoleic acid (ALA) via elongases ELO-1/2 and Δ5 desaturase which is rate-limiting. Employing liquid chromatography mass spectrometry (LC-MS/MS), we identified endocannabinoid-like ethanolamine and glycerol derivatives of JuA and ω-3 AA. Like classical endocannabinoids, these lipids exhibited binding interactions with NPR-32, a G protein coupled receptor (GPCR) shown to act as endocannabinoid receptor in C. elegans. Our study suggests that the eicosatetraenoic acids AA, ω-3 AA and JuA share similar biological functions. This biosynthetic plasticity of eicosatetraenoic acids observed in C. elegans uncovers a possible biological role of JuA and associated ω-3 endocannabinoids in Δ6 desaturase deficiencies, highlighting the importance of ALA.

9 January 2026 in PLOS ONE
Verified
Journal Article
Open access
PDF file
VFVanessa Fargnoli
Vanessa Fargnoli
SCSerafina Calarco
Serafina Calarco
CTCatherine Thomas
Catherine Thomas
CTCaroline Thomas
Caroline Thomas
CIClaudius Novchovick Mone Iye
Claudius Novchovick Mone Iye
KTKevin Tetteh
Kevin Tetteh
Malaria remains a major global health challenge. Prompt, accurate diagnosis is crucial for effective case management. Current diagnostic approaches rely on invasive or minimally invasive sampling via venous or fingerpick blood draw, posing a risk to healthcare workers via the handling of potentially infectious body fluids. They may also be a barrier to recipients, particularly in malaria-endemic areas where there is routine testing of non-symptomatic individuals. Non-invasive tests based on saliva, exhaled volatile organic compounds (VOCs), and transdermal detection have the potential to increase case detection and linkage to care while reducing biosafety risks. Knowledge gaps exist regarding the feasibility and acceptability of these tools. This qualitative study, conducted in Indonesia, Peru, and Rwanda, aimed to generate evidence from end-users around the potential adoption of non-invasive diagnostic technologies, to determine whether these technologies are fit for purpose. Between October and November 2023, 24 semi-structured interviews were conducted with stakeholders and professionals working at borders, and 16 focus group discussions were conducted with caregivers of children under 5 years, pregnant women, healthcare workers, teachers and other community members (139 participants in total). The comfort non-invasive approaches offer to recipients of care was widely noted, especially compared with blood draw, which is considered painful for children. Ease of use and rapid diagnostic capabilities enabling real-time disease diagnosis were perceived as particularly beneficial in remote areas with limited healthcare infrastructure. Device portability was seen as a game-changer. Major concerns were the lack of information regarding the accuracy of non-invasive tools compared with established methods, the lack of trust in tests targeting specimens other than blood products, and their inability to differentiate between malaria species. Early engagement with stakeholders in the development of novel interventions is essential to ensure that end products meet the needs of communities.

20 August 2021 in medRxiv
Verified
Preprint
Open access
PDF file
JVJennifer Villers
Jennifer Villers
AHAndre Henriques
Andre Henriques
SCSerafina Calarco
Serafina Calarco
MRMarkus Rognlien
Markus Rognlien
NMNicolas Mounet
Nicolas Mounet
OKOlivia Keiser
Olivia Keiser
A bstract: Background: Indoor aerosol transmission of SARS-CoV-2 has been widely recognized, especially in schools where children remain in closed indoor spaces and largely unvaccinated. Measures such as strategic natural ventilation and high efficiency particulate air (HEPA) filtration remain poorly implemented and mask mandates are often progressively lifted as vaccination rollout is enhanced. Methods: We adapted a previously developed aerosol transmission model to study the effect of interventions (natural ventilation, face masks, HEPA filtration, and their combinations) on the concentration of virus particles in a classroom of 160 m 3 containing one infectious individual. The cumulative dose of viruses absorbed by exposed occupants was calculated. Results: The most effective single intervention was natural ventilation through the full opening of six windows all day during the winter (14-fold decrease in cumulative dose), followed by the universal use of surgical face masks (8-fold decrease). In the spring/summer, natural ventilation was only effective (≥ 2-fold decrease) when windows were fully open all day. In the winter, partly opening two windows all day or fully opening six windows at the end of each class was effective as well (≥ 2-fold decrease). Opening windows during yard and lunch breaks only had minimal effect (≤ 1.2-fold decrease). One HEPA filter was as effective as two windows partly open all day during the winter (2.5-fold decrease) while two filters were more effective (4-fold decrease). Combined interventions (i.e., natural ventilation, masks, and HEPA filtration) were the most effective (≥ 30-fold decrease). Combined interventions remained highly effective in the presence of a super-spreader. Conclusions: Natural ventilation, face masks, and HEPA filtration are effective interventions to reduce SARS-CoV-2 aerosol transmission. These measures should be combined and complemented by additional interventions (e.g., physical distancing, hygiene, testing, contact tracing, and vaccination) to maximize benefit.

27 April 2022 in medRxiv
Verified
Preprint
Open access
PDF file
SCSerafina Calarco
Serafina Calarco
BFB. Leticia Fernandez-Carballo
B. Leticia Fernandez-Carballo
TKThomas Keller
Thomas Keller
SWStephan Weber
Stephan Weber
MJMeike Jakobi
Meike Jakobi
SDSabine Dittrich
Sabine Dittrich
Accurate and precise point-of-care (POC) testing for C-reactive protein (CRP) can help support healthcare providers in the clinical management of patients. Here, we compared the analytical performance of 17 commercially available POC CRP tests to enable more decentralized use of the tool. The following CRP tests were evaluated. Eight quantitative tests: QuikRead go (Aidian), INCLIX (Sugentech), Spinit (Biosurfit), LS4000 (Lansionbio), GS 1200 (Gensure Biotech), Standard F200 (SD Biosensor), Epithod 616 (DxGen), IFP-3000 (Xincheng Biological); and nine semi-quantitative tests: Actim CRP (ACTIM), NADAL Dipstick (nal von minden), NADAL cassette (nal von minden), ALLTEST Dipstick (Hangzhou Alltest Biotech), ALLTEST Cassette cut-off 10-40-80 (Hangzhou Alltest Biotech), ALLTEST Cassette cut-off 10-30 (Hangzhou Alltest Biotech), Biotest (Hangzhou Biotest Biotech), BTNX Quad Line (BTNX), BTNX Tri Line (BTNX). Stored samples (n=660) had previously been tested for CRP using Cobas 8000 Modular analyzer (Roche Diagnostics International AG, Rotkreuz, Switzerland (reference standards). CRP values represented the clinically relevant range (10-100 mg/L) and were grouped into four categories ( 80mg/L) for majority of the semi-quantitative tests. Among the eight quantitative POC tests evaluated, QuikRead go and Spinit exhibited better agreement with the reference method, showing slopes of 0.963 and 0.921, respectively. Semi-quantitative tests with the four categories showed a poor percentage agreement for the intermediate categories and higher percentage agreement for the lower and upper limit categories. Analytical performance varied considerably for the semi-quantitative tests, especially among the different categories of CRP values. Our findings suggest that quantitative tests might represent the best choice for a variety of use cases, as they can be used across a broad range of CRP categories.

1 April 2026 in medRxiv
Verified
Preprint
Open access
PDF file
MHMegan A Hansen
Megan A Hansen
ANAlexandra de Nooy
Alexandra de Nooy
SCSerafina Calarco
Serafina Calarco
KTKevin Tetteh
Kevin Tetteh
BNBrooke Nichols
Brooke Nichols
Background: Malaria rapid diagnostic tests (RDTs) are widely used to detect and treat malaria infections, yet a diagnostic gap remains. With turnaround times of ∼15 minutes, RDTs may be too slow to enable broad-scale implementation in certain contexts. Novel non-invasive diagnostics (NIDs) have potential to provide faster (<5 minutes), sensitive (90% for symptomatic, 65% for asymptomatic carriage), and cost-effective alternatives, which may increase testing throughput, enhance case detection, guide appropriate antimicrobial use, and reduce waste by using fewer consumables. Their potential impact has yet to be investigated. Methods: We modeled a country-agnostic population of 10 million individuals to assess the impact of population-level scale-up of four malaria testing strategies for active case-finding: 1) current practice (50% syndromic diagnosis and 50% RDTs), 2) full RDT scale-up, 3) full NID implementation, and 4) NID screening plus confirmatory RDT, using a decision-tree model of the malaria diagnostic and care cascade. We varied prevalence (0.02–0.25) and proportion of cases with symptoms (0.05–0.60) to evaluate strategy performance across epidemiological contexts. We investigated case detection rates, antimicrobial use, incremental cost-effectiveness ratios (ICERs) per disability adjusted life year (DALY) averted, net positive treatment outcomes, and threshold performance levels at which an NID would outperform RDTs. Results: Full NID implementation (strategy 3) yielded the highest case detection rates (up to 85%), followed by strategies 2, 4, and 1 (45%, 38%, 36% respectively). NID-based methods (strategies 3 and 4) saved costs and RDT scale-up was cost-effective at averting DALYs compared to current practice (ICERs: $60–1,270). Despite high case detection, universal NID testing spiked unnecessary antimicrobial use. Overall, our results suggest that an NID with 55% asymptomatic sensitivity and 84% specificity, followed by RDT confirmation (strategy 4), could simultaneously improve case detection, reduce antimicrobial overuse, and limit costs. Conclusions: This modeling analysis suggests that NIDs can sustainably optimize malaria case detection in symptomatic and asymptomatic cases and reduce costs, potentially making them a valuable addition to the diagnostic toolbox. When paired with confirmatory RDTs, they could help reduce inappropriate antimicrobial use, supporting drug efficacy amid rising resistance. Further research should assess their real-world utility, feasibility, and scalability for malaria surveillance and elimination efforts.