Sivaprakash A

Dr. Sivaprakash A

MEPCO SCHLENK ENGINEERING COLLEGE
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
Aravind C. K.Aravind C. K.
Aravind C. K.
Pandia Rajan JeyarajPandia Rajan Jeyaraj
Pandia Rajan Jeyaraj
Sivaprakash ASivaprakash A
Sivaprakash A
THANIKANTI SUDHAKAR BABUTHANIKANTI SUDHAKAR BABU
THANIKANTI SUDHAKAR BABU
Md. Rabiul IslamMd. Rabiul Islam
Md. Rabiul Islam
Synchronization is a crucial problem in the grid-connected inverter’s control and operation. A phase-locked loop (PLL) is a typical grid synchronization strategy, which ought to have a high resistance to power system uncertainties since its sensitivity influences the generated reference signal. The traditional PLL catches the phase and frequency of the input signal via the feedback loop filter (LF). In general, to enhance the steady-state capability during distorted grid conditions generally, a filter tuned for nominal frequency is used. This PLL corrects large frequency deviations around the nominal frequency, which increases the PLL’s locking time. Therefore, this paper presents an adaptive feed-forward PLL, where the input signal frequency and phase under large frequency deviations are tracked precisely, which overcomes the above-mentioned limitations. The proposed adaptive PLL consists of a feedback loop that reduces the phase error. The feed-forward loop predicts the frequency and phase error, and the frequency adaptive FIR filter reduces the ripples in output, which is due to input distortions. The adaptive mechanism adjusts the gain of the filter in accordance with the supply frequency. This reduces the phase and frequency error and also decreases the locking time under wide frequency deviations. To verify the effectiveness of the proposed adaptive feed-forward PLL, the system was tested under different grid abnormal conditions. Further, the stability analysis has been carried out via a developed prototype test platform in the laboratory. To bring the proposed simulations into real-time implementations and for control strategies, an Altera Cyclone II field-programmable gate array (FPGA) board has been used. The obtained results of the proposed PLL via simulations and hardware are compared with conventional techniques, and it indicates the superiority of the proposed method. The proposed PLL effectively able to tackle the different grid uncertainties, which can be observed from the results presented in the result section.

23 August 2019 in Australian Journal of Electrical and Electronics Engineering
Verified
Journal Article
Closed access
RVR. Pon Vengatesh
R. Pon Vengatesh
SRS. Edward Rajan
S. Edward Rajan
Sivaprakash ASivaprakash A
Sivaprakash A
One of the important factors to be considered in an electric power system is to maintain the frequency constant, so that power stations run satisfactorily in synchronise among the connected pool of power generation systems. The main purpose of load frequency control (LFC) is to reduce the frequency deviation and net interchange of power flow between electrical power generating units and for achieving steady-state error to be zero. This research paper proposes the way to improve the LFC by employing energy storage systems (battery energy storage systems and superconducting magnetic energy storage (SMES)) during change in load demand. The energy storage devices are acting quickly and they are effectively damp electro mechanical oscillations in a power system. Moreover, they provide storage capacity and the kinetic energy of the generator shares the sudden changes in power requirement. An integrated hybrid BES and SMES energy storage systems along with LFC minimise the deviation of frequency by contribution of additional power requirement. Investigating the performance of the LFC with storage system under step change of load (∆Pd) has been analysed by employing proportional-integral (PI) and fuzzy logic controller (FLC) for frequency regulation and load tracking. Even, the PI controller attains zero steady-state error in system frequency, it has unsatisfied dynamic (overshoots and settling time) performance followed by disturbances. The mismatch power in the power system makes frequency deviation followed by the change in load demand and electrical power generation and it is balanced by employing of an energy storage system with proper controller. The simulation results are illustrated that the performance of LFC system is enhanced by BES storage system which effectively reduces frequency deviation than SMES system. The comparative analysis has been made for LFC with BES, SMES and hybrid storage system employing FLC and PI controller design also. A significant improvement in the frequency profile has been obtained with FLC controller than PI controller followed by the step load changes.

27 September 2019 in Current Medical Imaging
Verified
Journal Article
Closed access
PDF file
Sivaprakash ASivaprakash A
Sivaprakash A
SRSamuel Nadar Edward Rajan
Samuel Nadar Edward Rajan
SSSundaramoorthy Selvaperumal
Sundaramoorthy Selvaperumal
Background: Privacy protection has been a critical issue in the delivery of medical images for telemedicine, e-health care and other remote medical systems. Objective: The aim of this proposed work is to implement a secure, reversible, digital watermarking technique for the transmission of medical data remotely in health care systems. Methods: In this research work, we employed a novel optimized digital watermarking scheme using discrete wavelet transform and singular value decomposition using cuckoo search algorithm based on Lévy flight for embedding watermark into the grayscale medical images of the patient. The performance of our proposed algorithm is evaluated on four different 256 × 256 grayscale host medical images and a 32 × 32 binary logo image. Results: The performance of the proposed scheme in terms of peak signal to noise ratio was remarkably high, with an average of 55.022dB compared to other methods. Conclusion: Experimental results reveal that the proposed method is capable of achieving superior performance compared to some of the state-of-art schemes in terms of robustness, security and high embedding capacity which is required in the field of telemedicine and e-health care system.

1 September 2019 in Journal of Medical Imaging and Health Informatics
Verified
Journal Article
Closed access
Sivaprakash ASivaprakash A
Sivaprakash A
SRSamuel Nadar Edward Rajan
Samuel Nadar Edward Rajan
SSS. Selvaperumal
S. Selvaperumal
Background: Copyright protection of medical images and its Integrity has become one of the key problems in the field of telemedicine. Objectives: In this paper, we propose a novel robust watermarking scheme based on firefly algorithm in the transform domain. Methods: The watermark embedding and extraction are implemented in the discrete wavelet transform and singular value decomposition transform domain. During the embedding stage, the host image is modified into sub band of separate frequencies by three level DWT. The watermark image is then embedded into the low pass and high pass sub band of the host image to modify the watermark invisible and robust. We further used firefly algorithm, to find optimal value and improved the quality and robustness of the watermark embedded in the medical image. Results: Experimental results indicate excellent invisibility compared to other state of the art method of the extracted watermark image of PSNR value 50.2175 dB and a maximum NCC value of 0.9982 subjected to different noises and attacks such as JPEG compression, rotation, Gaussian noise, cropping, and median filter. Conclusions: Experimental results shows that our proposed method is capable of achieving better performance when compared to other state of art techniques in terms of robustness and high embedding capacity which is crucial for telemedicine applications.

1 January 2021 in Computers, Materials & Continua
Verified
Journal Article
Open access
Pandia Rajan JeyarajPandia Rajan Jeyaraj
Pandia Rajan Jeyaraj
Aravind C. K.Aravind C. K.
Aravind C. K.
Sivaprakash ASivaprakash A
Sivaprakash A
ENEdward Rajan Samuel Nadar
Edward Rajan Samuel Nadar
Hegazy RezkHegazy Rezk
Hegazy Rezk
THANIKANTI SUDHAKAR BABUTHANIKANTI SUDHAKAR BABU
THANIKANTI SUDHAKAR BABU
The power transfer capability of the smart transmission grid-connected networks needs to be reduced by inter-area oscillations. Due to the fact that inter-area modes of oscillations detain and make instability of power transmission networks. This fact is more noticeable in smart grid-connected systems. The smart grid infrastructure has more renewable energy resources installed for its operation. To overcome this problem, a deep learning wide-area controller is proposed for real-time parameter control and smart power grid resilience on oscillations inter-area modes. The proposed Deep Wide Area Controller (DWAC) uses the Deep Belief Network (DBN). The network weights are updated based on real-time data from Phasor measurement units. Resilience assessment based on failure probability, financial impact, and time-series data in grid failure management determine the norm . To demonstrate the effectiveness of the proposed framework, a time-domain simulation case study based on the IEEE-39 bus system was performed. For a one-channel attack on the test system, the resiliency index increased to 0.962, and inter-area damping was reduced to 0.005. The obtained results validate the proposed deep learning algorithm’s efficiency on damping inter-area and local oscillation on the 2-channel attack as well. Results also offer robust management of power system resilience and timely control of the operating conditions.