To present population data on standardized measures of dexterity, activity performance, disability, health-related quality of life (HRQoL) and community integration for persons with upper limb ampu...
1 June 2020 in Prosthetics and Orthotics International
The most crucial aspect of a prosthesis is the socket, as it will directly determine gait stability and quality. The current standard of care ischial ramus containment socket is reported to increase coronal stability through gait; however, socket discomfort is the primary complaint among prosthetic users. The purpose of this study is to compare ischial ramus containment to alternatives in the transfemoral amputee population. All subjects were fit with three different sockets: traditional ischial ramus containment, a dynamic socket, and a sub-ischial. In this study, authors hypothesized socket skeletal motion would be equivalent across interventions. Single-blind, repeated-measures, three-period randomized crossover clinical trial. Outcome measures were socket comfort score and skeletal motion, viewed coronally with X-ray measuring the position of the skeleton in relationship to the socket in full weight-bearing and full un-loading. The mean age was 38.2 and mean Amputee Mobility Predictor score was 40. Mean vertical movement, horizontal movement, single limb prosthetic stance, mean femoral adduction in swing and stance, and median socket comfort score were not statistically different. The socket design did not significantly effect skeletal motion and socket comfort. All socket designs are suitable depending on the patient-centric preferences and prosthetist skill set. The comfort of the standard of care transfemoral amputation socket has been widely reported as problematic. A comparison of alternative designs in a controlled clinical trial environment will assist the clinician in understanding the impact of design regarding skeletal motion and comfort. Users could benefit from alternatives applied in clinical practice.
Technology-based outcomes have recently been proposed to complement the standard Four Square Step Test (FSST) by providing a decomposition of the sequences and information about the stepping pattern. A test-retest study and a randomized crossover design have been used to determine immediate test-retest reliability and to assess discriminant validity, in persons with a unilateral transfemoral amputation, for the parameters computed by an instrumented version of the Four Square Step Test. Twenty adults, independent and unlimited community ambulators, with a unilateral transfemoral amputation, performed two Four Square Step Tests on a pressure mat first with a microprocessor knee, then, a few weeks later with another one. One of these prosthetic knees was acknowledged to be superior and to provide functional improvement. Test-retest, intraclass correlation coefficients and minimal detectable change at 95% confidence level were calculated for each variable. Paired samples t-tests were then used to identify differences between the two microprocessor knee systems. The test-retest reliability of most outcome measures was good to excellent. Few variables showed a systematic difference and a trend to improve between test 1 and test 2. When comparing both microprocessor knees, significant differences in the expected direction were observed, with interpretation in accordance with a functional improvement. Importantly, we highlighted that various strategies to improve the performance in the test might complexify the interpretation of the most detailed measurement. The instrumented Four Square Step test provides reliable measures with satisfactory test-retest reliability and discriminant validity in persons with unilateral transfemoral amputation.