Bety Denissa Burghele

Dr. Bety Denissa Burghele

Center for Applied Environmental Research, Babeș-Bolyai University, Fântânele 30, RO – 400294, Cluj-Napoca, Romania
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2020 in Environmental Geochemistry and Health
Verified
Journal Article
Closed access
PDF file
ŞFŞtefan Florică
Ştefan Florică
Bety Denissa BurgheleBety Denissa Burghele
Bety Denissa Burghele
NBNicoleta Brișan
Nicoleta Brișan
RBRobert Begy
Robert Begy
VCVlad Codrea
Vlad Codrea
CSCarlos Sainz
Carlos Sainz

1 December 2020 in Journal of Cleaner Production
Verified
Journal Article
Closed access
MBMihail Simion Beldean-Galea
Mihail Simion Beldean-Galea
TDTiberius Dicu
Tiberius Dicu
ACAlexandra Cucoş
Alexandra Cucoş
Bety Denissa BurgheleBety Denissa Burghele
Bety Denissa Burghele
Tiberiu CATALINATiberiu CATALINA
Tiberiu CATALINA
CSCarlos Sainz
Carlos Sainz

11 May 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TDT. Dicu
T. Dicu
Bety Denissa BurgheleBety Denissa Burghele
Bety Denissa Burghele
MBM. Botoş
M. Botoş
ACA. Cucoș
A. Cucoș
GDG. Dobrei
G. Dobrei
CSC. Sainz
C. Sainz
The present study aims to identify novel means of increasing the accuracy of the estimated annual indoor radon concentration based on the application of temporal correction factors to short-term radon measurements. The necessity of accurate and more reliable temporal correction factors is in high demand, in the present age of speed. In this sense, radon measurements were continuously carried out, using a newly developed smart device accompanied by CR-39 detectors, for one full year, in 71 residential buildings located in 5 Romanian cities. The coefficient of variation for the temporal correction factors calculated for combinations between the start month and the duration of the measurement presented a low value (less than 10%) for measurements longer than 7 months, while a variability close to 20% can be reached by measurements of up to 4 months. Results obtained by generalized estimating equations indicate that average temporal correction factors are positively associated with CO2 ratio, as well as the interaction between this parameter and the month in which the measurement took place. The impact of the indoor-outdoor temperature differences was statistically insignificant. The obtained results could represent a reference point in the elaboration of new strategies for calculating the temporal correction factors and, consequently, the reduction of the uncertainties related to the estimation of the annual indoor radon concentration.

8 August 2012 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
Bety Denissa BurgheleBety Denissa Burghele
Bety Denissa Burghele
CCC. Cosma
C. Cosma
A new thoron/radon survey was started in the north-western part of Romania, covering three counties, using discriminative detectors (RADUET). All detectors were deployed throughout 3 months, covering the spring period. The measured radon and thoron concentration ranged from 31 to 414 Bq m−3 and from below the detection limit to 235 Bq m−3, respectively. In this survey, 35 schools were submitted to investigation; 21 of the schools included in this study presented radon concentrations higher than 100 Bq m−3, the reference level recommended by the World Health Organization in 2009. The seasonal effective dose calculated from these exposures, overlapping all three counties, ranged between 0.32 and 0.54 mSv.

IMIon-Costinel Mareș
Ion-Costinel Mareș
Tiberiu CATALINATiberiu CATALINA
Tiberiu CATALINA
MIMarian-Andrei Istrate
Marian-Andrei Istrate
Cucos Alexandra LauraCucos Alexandra Laura
Cucos Alexandra Laura
TDTiberius Dicu
Tiberius Dicu
RPRazvan Stefan Popescu
Razvan Stefan Popescu
The purpose of this article is the assessment of energy efficiency and indoor air quality for a single-family house located in Cluj-Napoca County, Romania. The studied house is meant to be an energy-efficient building with thermal insulation, low U-value windows, and a high efficiency boiler. Increasing the energy efficiency of the house leads to lower indoor air quality, due to lack of natural ventilation. As the experimental campaign regarding indoor air quality revealed, there is a need to find a balance between energy consumption and the quality of the indoor air. To achieve superior indoor air quality, the proposed mitigation systems (decentralized mechanical ventilation with heat recovery combined with a minimally invasive active sub-slab depressurization) have been installed to reduce the high radon level in the dwelling, achieving an energy reduction loss of up to 86%, compared to the traditional natural ventilation of the house. The sub-slab depressurization system was installed in the room with the highest radon level, while the local ventilation system with heat recovery has been installed in the exterior walls of the house. The results have shown significant improvement in the level of radon decreasing the average concentration from 425 to 70 Bq/m3, respectively the carbon dioxide average of the measurements being around 760 ppm. The thermal comfort improves significantly also, by stabilizing the indoor temperature at 21 °C, without any important fluctuations. The installation of this system has led to higher indoor air quality, with low energy costs and significant energy savings compared to conventional ventilation (by opening windows).

30 December 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
NBNicoleta Brișan
Nicoleta Brișan
GDGabriel Cristian Dobrei
Gabriel Cristian Dobrei
Bety Denissa BurgheleBety Denissa Burghele
Bety Denissa Burghele
Cucos Alexandra LauraCucos Alexandra Laura
Cucos Alexandra Laura
Schools are a category of public buildings with a high radon exposure risk, due to their high occupancy factor. In Romania, the elaboration of a methodology for radon measurements in schools is a necessity imposed both by the European legislation and by the relatively high percentage (about 10%) of the mapped territory with a potential increased risk of exposure to the action of ionizing radiation emitted by radon. In order to optimize the design of a national survey aimed to evaluate radon exposure of children in Romanian schools, we conducted a pilot study in two schools in Cluj-Napoca, following the screening measurements carried out in 109 schools and kindergartens from five counties. The specific steps that must be followed were described, taking into account the international protocols and particularities of Romanian territory. The proposed approach could act as a guide for other large buildings and is implicit for the implementation of National Radon Action Plan, approved by HG no. 526/12 July 2018 in accordance with Council Directive 2013/59/EURATOM. The obtained results indicate that a high probability of annual radon concentration above the national reference level is to be expected in schools.