Background and objectives: The introduction of novel techniques in total knee arthroplasty (TKA) aiming to enhance outcomes and satisfaction of the procedure is constantly ongoing. In order to evidence a priority of one, we have conducted a randomized controlled trial with the aim of comparing patient-reported functional outcomes, radiographic outcomes and intraoperative measures between imageless (NAVIO and CORI), robotic-assisted (ra)- TKA (ra-TKA) and manual TKA (mTKA) for primary knee osteoarthritis (KOA). Materials and Methods: A total of 215 patients with the diagnosis of KOA of the knee were randomly assigned to one of the three groups: NAVIO (76 patients) or CORI (71 patients) robotic-assisted TKA, or manual technique (68 patients) TKA. The primary outcome (Knee Injury and Osteoarthritis Outcome Study [KOOS]), Visual Analogue Scale (VAS), Range of motion (ROM), femoral component rotational alignment and the secondary outcomes (surgery time, blood loss, complications, and revision at 12 months after surgery) were compared between three groups. KOOS and VAS were collected at particular follow up visits from each patient individually and ROM in flexion and extension was assessed during the physical examination. Femoral component rotational alignment was measured on the CT scan performed postoperatively utilizing the Berger’s method. Statistical significance was set at p < 0.05. Results: Both the ra-TKA groups and mTKA group displayed significant improvements in the majority of the functional outcome scores at 12 months. Despite having more prominent surgery time (NAVIO: mean +44.5 min in comparison to mTKA and CORI: mean +38.5 min in comparison to mTKA), both NAVIO and CORI tend to achieve highly accurate femoral component rotational alignment with mean radiographic scores in NAVIO vs. CORI vs. mTKA of 1.48° vs. 1.33° vs. 3.15° and lower blood loss (NAVIO: 1.74; CORI: 1.51; mTKA: 2.32. Furthermore, the investigation revealed the significant difference in femoral component rotational alignment between mTKA—NAVIO and mTKA—CORI and significantly different KOOS scores in NAVIO vs. CORI vs. mTKA of 87.05 vs. 85.59 vs. 81.76. Furthermore, the KOOS analysis showed between group significant statistical differences, but did not reach minimal clinically significant difference. There were no differences in postoperative ROM and VAS. There were no differences in complications between groups. Conclusions: To achieve a successful TKA, the precise tool and individualised objective is of great importance. The results suggest satisfactory results after both ra-TKA methods and mTKA. Ra-TKA and mTKA stand for a safe and reliable treatment method for OA. Patients reported excellent alleviation in functional outcomes and the radiological results revealed that the better precision does not necessarily lead to a better outcome. Therefore, ra-TKA does not imply strong enough advantages in comparison to the manual method, especially in terms of cost-efficiency and surgical time.
This narrative review provides the outcomes of minimally invasive surgery (MIS) and describes the available conservative treatment options for patients with osteoporotic vertebral compression fractures (OVCFs) that have risk factors for Kummell’s disease (KD). It aims to explore the evidence, emphasize the possible therapy complications, and aims to propose the most efficient clinical strategies for maintaining a good overall condition of individuals who may suffer from neurological deficits from a late-diagnosed OVCF complication. The secondary objective is to sum up the diagnostic particularities concerning individuals prone to OVCFs and KD, as the major risk factor for developing these severe conditions remains osteoporosis. Findings of our narrative review are based on the results found in PubMed, Embase, and Google Scholar from the beginning of their inception to December 2020, described independently by two authors. All of the studies included in the review focus on reporting the following treatment methods: conservative methods, vertebroplasty, kyphoplasty, targeted percutaneous vertebroplasty, frontal and side-opening cannula vertebroplasty, SpineJack, bone-feeling mesh container treatment, and the difference in the cement viscosity used (high vs. low) and the approach used (unilateral vs. bilateral). The comparison of randomized control trials (RCTs) as well as prospective and retrospective case series showed a comparable efficacy of kyphoplasty and vertebroplasty, and described cement-augmented screw fixation and the SpineJack system as effective and safe. Although it should be noted that several studies revealed inconsistent results in regards to the efficacy of using back braces and analgesics in patients who had vertebral fractures that were overlooked or not enrolled in any active surveillance program to track the patient’s deterioration immediately. Nevertheless there are non-standardized guidelines for treating patients with OVCFs and their complications already established. Using these guidelines, a treatment plan can be planned that takes into consideration the patients’ comorbidities and susceptibilities. However, the primary approach remains the management of osteoporosis and that is why prophylaxis and prevention play a crucial role. These measures reduce the risk of disease progression. Unfortunately, in the majority of cases these measures are not taken into account and KD develops.
Aim: This study aimed to identify and analyze the top 100 most cited digital health and mobile health (m-health) publications. It could aid researchers in the identification of promising new research avenues, additionally supporting the establishment of international scientific collaboration between interdisciplinary research groups with demonstrated achievements in the area of interest. Methods: On 30th August, 2023, the Web of Science Core Collection (WOSCC) electronic database was queried to identify the top 100 most cited digital health papers with a comprehensive search string. From the initial search, 106 papers were identified. After screening for relevance, six papers were excluded, resulting in the final list of the top 100 papers. The basic bibliographic data was directly extracted from WOSCC using its “Analyze” and “Create Citation Report” functions. The complete records of the top 100 papers were downloaded and imported into a bibliometric software called VOSviewer (version 1.6.19) to generate an author keyword map and author collaboration map. Results: The top 100 papers on digital health received a total of 49,653 citations. Over half of them (n = 55) were published during 2013–2017. Among these 100 papers, 59 were original articles, 36 were reviews, 4 were editorial materials, and 1 was a proceeding paper. All papers were written in English. The University of London and the University of California system were the most represented affiliations. The USA and the UK were the most represented countries. The Journal of Medical Internet Research was the most represented journal. Several diseases and health conditions were identified as a focus of these works, including anxiety, depression, diabetes mellitus, cardiovascular diseases, and coronavirus disease 2019 (COVID-19). Conclusions: The findings underscore key areas of focus in the field and prominent contributors, providing a roadmap for future research in digital and m-health.
Objectives: The aim of this study was to assess the relationship between the countermovement jump (CMJ) and sprint performance of professional football players, and to determine which strength and speed elements assessed by the CMJ translate into effective running. Methods: The research sample comprised 87 male professional football players (age 23.7 ± 4.20 years; body mass 82.33 ± 6.56 kg; body height 1.86 ± 0.05 m) who performed the CMJ on a dual-force platform, as well as the 30 m sprint test. The time and velocity of the run were recorded by photocells at 0, 5, 10, and 30 m of the distance. Results: No significant differences were noted in the time or velocity of the sprint over the initial 5 m between the groups of football players with a higher and lower braking rate of force development (RFD) in the CMJ (p > 0.05). However, at subsequent intervals (5–10 m and 10–30 m), players with a higher braking RFD achieved significantly better time and velocity than those with a lower RFD. Significant correlations in the group with a lower braking RFD between the CMJ and sprint variables occurred in the propulsion phase of the CMJ and most of them were in the first interval (0–5 m). In the group with a higher braking RFD, significant relationships were visible in both the propulsion (concentric) and braking (eccentric) phases of the CMJ, mainly during the second and third intervals of the sprint test. Conclusions: The noted observations may suggest that the relationship between strength and running performance is more complex than previously indicated, and that higher strength in the CMJ does not fully correlate with better sprinting. Therefore, it has been hypothesized that training aimed at generally increasing strength may not always be fully beneficial for running performance in football players and hence specific training guidelines are suggested for targeted strengthening of the required muscle performance characteristics. This may possibly contribute to reducing the unnecessary muscle overload during both training and matches, thereby preventing sports-related injuries.
Background and Objectives: Total knee arthroplasty (TKA) is the most effective treatment method for end-stage osteoarthritis. One of the most important aspects of this surgery is adequate implant positioning, as it guarantees the desired outcome of restoring limb biomechanics. Surgical technique is being continuously improved along with hardware development. There are two novel devices designed to help establish proper femoral component rotation: soft-tissue tensor and robotic–assisted TKA (RATKA). This study compared the femoral component rotation achieved with the use of three methods: RATKA, soft tissue tensioner and the conventional measured-resection technique, all of them utilizing anatomical design prosthesis components. Materials and Methods: A total of 139 patients diagnosed with end-stage osteoarthritis underwent total knee arthroplasty between December 2020 and June 2021. After the surgery, they were divided into three groups depending on procedure technique and implant type: Persona (Zimmer Biomet) + Fuzion Balancer, RATKA + Journey II BCS or conventional TKA + Persona/Journey. Postoperatively, a computed tomography examination was performed in order to measure femoral component rotation. All three groups were compared independently during statistical analysis. Fisher’s exact, Kruskal–Wallis and Dwass–Steel–Crichtlow–Fligner tests were used for particular calculations. Results: Statistically significant differences in femoral component rotation between groups were noticed. However, in terms of values other than 0° in external rotation, no significant variance was revealed. Conclusions: Additional total knee arthroplasty instruments seem to improve the outcomes of the surgery, providing better component positioning than in the conventional measured-resection technique based only on bone landmarks.
Background: Velocity-based training (VBT) requires measurement of the velocity at which the barbell is moved in the concentric phase with regard to different resistance exercises, which provides accurate, indirect estimations of 1 RM. However, for assessing punch performance, no study has been carried out to date. The purpose of this study was to analyse the reliability of the GymAware linear transducer for the measurement of barbell velocity during the landmine push throw (LPT) test using four loads. Methods: Twenty-five healthy, physically active male students, aged 24.13 ± 2.82 years, volunteered to take part in this study. The reliability of the LPT test was measured at two separate visits, with a 2-day interval between them. One series of the test protocol included four parts of the LPT test with progressively increasing loads (20, 25, 30, and 35 kg) and 5 min intervals for rests between loads. Results: For all four loads, excellent intra-rater and test–retest reliability was noted for the mean force variable (ICC = 0.97–0.99). Additionally, very strong and significant correlations were established between measurements (r = 0.96–0.99). Poor reliability was observed for barbell height and total work (ICC below 0.5). A trend of decreasing reliability was detected with increasing barbell load. Furthermore, measurements without the barbell throw were more reliable than those with it. Conclusions: These results support the use of the GymAware linear transducer to track barbell velocity during the LPT test. This device may have valuable practical applications for strength and conditioning coaches. Therefore, we suggest that the LPT assessed with the GymAware linear transducer may be a useful method for evaluating upper limb strength and power during boxing punches.