Sun Ying

Dr. Sun Ying


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZCZhehan Cai
Zhehan Cai
ZWZhijian Wang
Zhijian Wang
KLKaiqi Lin
Kaiqi Lin
SYSun Ying
Sun Ying
WZWeidong ZHUO
Weidong ZHUO
Currently, the seismic designs of reinforced concrete (RC) bridges with tall piers are often accomplished following the ductility-based seismic design method. Though the collapses of the RC bridges with tall piers can be avoided, they are likely to experience major damage and loss of functionality when subjected to strong near-fault ground motions. The objectives of this study are to put forward an innovative design concept of a tall-pier system and its application in tall-pier bridges. The concept of the innovative tall-pier system is derived from the principle of earthquake-resilient structures, and is to improve the seismic performances of the tall-pier bridges under strong near-fault ground motions. The proposed tall-pier system has a box section and is composed of four concrete-filled steel tubular (CFST) columns and energy dissipating mild steel plates (EDMSPs). Trial design of a bridge with the new composite tall-pier system is performed based on a typical continuous rigid frame highway bridge with conventional RC box section tall piers. Both static analysis and nonlinear time history analysis of both the bridges with the new composite tall piers and conventional RC tall piers under the near-fault velocity pulse-type ground motions were conducted in Midas Civil2019 and ABAQUS. The results show that: under the design-based earthquake (DBE), the CFST columns and connecting steel beams remain elastic in the bridge with the new composite tall piers, while the damage is found in the replaceable EDMSPs which help dissipate the seismic input energy. The displacement responses of the new bridge are significantly smaller than those of the conventional bridge under DBE. It is concluded that the bridge with the new composite tall piers is seismic resilient under near-fault ground motions.

4 April 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JHJiaqi Hu
Jiaqi Hu
Yin GuYin Gu
Yin Gu
JYJinhuang Yan
Jinhuang Yan
SYSun Ying
Sun Ying
XHXinyi Huang
Xinyi Huang
With the convenient and fast requirements for construction in bridge engineering, prefabricated assembly technology is widely applied in engineering construction. Typically, prefabricated bridge decks are connected through cast-in-place wet joints. Wet joints, as the primary load-bearing parts of bridge decks, undergo complex stress and are prone to cracking and damage. Particularly in the negative bending moment region of bridges, the influence of tensile stress on wet joints is more severe, thus enhancing the mechanical performance and crack resistance of joints becomes crucial. This paper investigates the mechanical behavior of prefabricated reinforced concrete bridge deck panels with variable cross-sections under negative bending moments, focusing on the performance of Ultra High-Performance Concrete (UHPC) wet joints. Full-scale experimental tests were conducted on a 176 m steel truss composite continuous rigid bridge, employing C50 concrete panels with UHPC wet joints. Results show three distinct stages: elastic, crack initiation and propagation, and failure. The maximum failure load reached 822 kN, with a maximum displacement of 21.64 mm. Concrete strains indicate compressive stress near the wet joint and tensile stress near the loading positions. Cracks primarily develop at the wet joint interface and propagate under increasing load, ultimately leading to flexural–shear failure near the variable cross-section of the wet joint. Numerical simulations using ABAQUS/CAE (2020) corroborate experimental findings, closely matching load-displacement curves and identifying damage locations. The study demonstrates that UHPC wet joints significantly enhance crack resistance, meeting design requirements for improved mechanical performance in bridge structures subjected to negative bending moments.

11 April 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
QHQiaozhu He
Qiaozhu He
SYSun Ying
Sun Ying
Yin GuYin Gu
Yin Gu
TWTong Wu
Tong Wu
This study investigates the structural performance of assembled rib-plate bridge abutments (ARBAs) with two different connection methods: bull leg bolt and flange connections. In addition, we explored the bending and shear performance of the connection parts and related areas to assess the damage characteristics and modes of these ARBAs. Utilizing model testing, a numerical analysis was conducted to define the force performance of the ARBA, with reference to a cast-in-place rib-plate abutment. The research results indicate that the bearing capacity and deformation capacity of the cap part of the assembled ribbed slab abutment model with cow leg connections are lower than those of the cast-in-place structure. When the structure fails, a 45° diagonal crack develops from the cross-section at the mid-span joint to the connection between the rib slab and the cap, until the concrete protective layer at the joint is crushed, exhibiting a shear failure mode. The bearing capacity of the assembly rib plate type abutment cap connected by the flange plate is basically the same as that of the cast-in-place structure, and the deformation capacity is weaker than that of the cast-in-place rib plate type abutment. The expansion of structural cracks is consistent with that of the rib plate type abutment connected by the cow leg. When the flange plate at the mid span is damaged, the contact surface between the flange plate and the concrete is pried off, resulting in the inability of the structure to continue bearing, exhibiting a shear failure mode. Through numerical simulation, taking the stress performance of the integral cast-in-place ribbed slab abutment as a reference, the assembled ribbed slab abutment connected by the flange plate is basically consistent with the integral cast-in-place ribbed slab abutment in terms of ultimate load, concrete damage, and steel reinforcement skeleton stress, and the connection device has not yet reached the yield state. The ultimate displacement is slightly weaker than that of the integral cast-in-place ribbed slab abutment. By comparison, it can be seen that the ultimate bearing capacity of the assembled ribbed slab abutment connected by the flange is basically the same as that of the cast-in-place ribbed slab abutment, and the stress performance can reach an “equivalent cast-in-place”, making it the preferred solution for the assembled abutment structure. The finite element parameter analysis of the flanged ARBA revealed that the thickness of the stiffening ribs, the number of bolts, and length of the flange plate anchoring steel plate were proportional to the ultimate load-bearing capacity of the prefabricated ARBA. In the case of no change in the structural damage mode, considering the economic benefits and load-bearing capacity of the structure, the following parameter combinations of the flanged ARBA are recommended: a thickness of 30 mm of the stiffening ribs, the number of bolts is 12, and a length of 50 cm of the length of flange plate anchoring steel plate.

5 October 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LJLiu JinFei
Liu JinFei
SYSun Ying
Sun Ying
WZWeidong ZHUO
Weidong ZHUO
天陈天海 陈
天海 陈
Yin GuYin Gu
Yin Gu
To investigate the seismic pounding response characteristics of a single-span simply supported reinforced concrete skew slab bridge and evaluate the applicability of different pounding models, shaking table tests were conducted on a 45° skew bridge, and a finite element model was established using SAP2000. The Kelvin and Hertz-damp models were compared under different pounding stiffness values (0.1–0.5k). The experimental results indicate that, without pounding, the acceleration response exhibits a pronounced dynamic amplification effect, while longitudinal and transverse displacements are larger on the acute side than on the obtuse side, accompanied by slight in-plane rotation of the girder. When pounding is considered, the bridge exhibits altered in-plane rotational behavior, which is restrained by the abutment. Meanwhile, the acceleration response is significantly amplified, with peak accelerations reaching 5–22 times the input peak ground acceleration (PGA), whereas the longitudinal displacement decreases and the in-plane rotational response is restrained. The numerical results demonstrate that the Hertz-damp model can reproduce the main response characteristics observed in the experiments. The quantitative error comparison indicates that stiffness values of 0.2–0.3k provide a reasonable balance between acceleration and displacement accuracy. Under the experimental and numerical conditions considered in this study, 0.2k can serve as a reference value within the investigated stiffness range. These findings provide a reference for selecting appropriate pounding models and pounding stiffness parameters in the seismic analysis of skew bridges.